1500 kVA diesel generator set

1500 kVA GENERATOR

JJP-M1200GF — 1500 kVA / 1200 kW prime, 1650 kVA / 1320 kW standby. 2,165 A per phase at 400 V, 268.7 L/h at full load. FOB China quoted against the engine and alternator you specify.

See the Full Specification
Other ratings in this range 100 kVA150 kVA200 kVA250 kVA300 kVA375 kVA400 kVA500 kVA625 kVA800 kVA1000 kVA1500 kVAAll 50–1500 kVA

1500 kVA Generator — JJP-M1200GF

Prime (PRP)
1500 kVA
1200 kW at 0.8 PF
Unlimited hours, 10% overload for 1 h in 12
Standby (ESP)
1650 kVA
1320 kW at 0.8 PF
Loss of mains only, 200 h/yr

1500 kVA is the prime rating on the nameplate, not a rounded-up figure — the frame maps exactly onto the requirement. 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, three-phase four-wire, 0.8 power factor.

How Many Amps Is a 1500 kVA Generator?

VoltagePhaseCurrent at 1500 kVASuggested breaker frame
380 V3-phase2,279 A3,200 A
400 V3-phase2,165 A3,200 A
415 V3-phase2,087 A3,200 A
440 V3-phase1,968 A2,500 A
480 V3-phase1,804 A2,500 A
220 V1-phase6,818 Aspecial winding
240 V1-phase6,250 Aspecial winding

I = kVA × 1000 ÷ (√3 × V). Breaker sizing at 125% of the 400 V figure gives 2,706 A, which lands on a 4,000 A frame. At this current the connection is busbar into a bespoke switchboard. Cable sizing and short-circuit coordination are project-specific and should be signed off by the installing engineer.

Fuel Consumption per Hour

LoadDiesel L/hUS gal/h
1500 kVA / 1200 kW (100%)268.7 L/h71.0
1200 kVA / 960 kW (80%)214.9 L/h56.8
900 kVA / 720 kW (60%)161.2 L/h42.6
600 kVA / 480 kW (40%)107.5 L/h28.4
300 kVA / 240 kW (20%)53.7 L/h14.2

Based on ≤187 g/kWh at 835 g/L diesel density — the same basis used across this site, so the figures compare directly with our other ratings. Consumption tracks load almost linearly in this class. The exact curve for the engine finally fitted is issued with the test report.

Engine and Alternator on the 1500 kVA Frame

At 1500 kVA the engine is selected per project rather than fixed on the datasheet. The usual candidates are the MTU 4000 series, the Cummins QSK60 series and the Perkins 4000 series, or an equivalent heavy-duty platform, coupled to a Leroy Somer or Stamford frame of matching pitch.

At this rating the engine choice drives the footprint, the fuel system, the service interval and the price far more than it does at 300 kVA, so we confirm the model against your load profile and your service network before quoting. Send the load schedule and we will come back with two or three engine options and the difference between them.

Controller is a Deep Sea DSE8610 or DEIF unit for parallel operation as standard at this rating, with DSE7320 MKII on single-set installations.

What Can a 1500 kVA Generator Power?

Data centre campus
110–135 racks at 10 kW each, normally as 2 × 1500 kVA in parallel for N+1. Parallel operation is specified with the order.
Heavy industrial plant
960–1,080 kW of connected load. The design case is the largest motor plus the base load, not the total connected figure.
Steel, cement or chemical works
Process drives, compressors and auxiliaries on a standby bus. High-harmonic loads require the alternator to be derated for the load type.
Teaching hospital or medical campus
800–1,000 beds across several buildings, with clinical circuits and the cold chain on the priority bus.
Large desalination plant
High-voltage pump motors on soft start, sequenced in fixed order. Confirm transient response against the largest motor before ordering.
Airport, port or shipyard
Shore power and terminal handling on standby, where load steps are frequent and unattended running is normal.

Frame, Weight and Installation

Overall dimensions and dry weight move with the engine and the alternator actually fitted, so we do not publish a single figure for this rating and then quote you a set that does not match it. The general arrangement drawing issued with your order carries the exact envelope, lifting points and centre of gravity for the configuration you buy.

What does not change is the site work. Allow clearance at the alternator end for cooling air, confirm canopy door swing on both long sides before siting, and cast a level concrete plinth rated for 1.5× the wet weight. At this rating the set is a heavy crane lift and is usually delivered as a containerised power unit. The lifting plan, floor loading and ventilation openings should be designed from the GA drawing, not from a catalogue.

Ask for the drawing for the engine you are considering — it is the only number worth designing a plant room around.

What Does a 1500 kVA Generator Cost?

At this rating the engine platform, the alternator frame and the switchgear are all project-specific, so a catalogue band would not survive contact with a real enquiry. We quote this rating against the engine and alternator you specify rather than publishing a catalogue band. What we need to give you a firm number: running kW and the largest motor, the duty (standby, prime or continuous), the destination port, and whether you want open skid, silent canopy or container. From those we confirm the engine option, the tank size and the canopy grade, and price it landed-ready. A sound-attenuated canopy typically adds 8–12% and roughly 200–300 kg at this rating; a synchronising panel, an ATS and the breaker are priced separately because they depend on the switchboard you already have.

1500 kVA Generator Questions

How many amps does a 1500 kVA generator deliver?

2,165 A per phase at 400 V three-phase, 2,279 A at 380 V, 1,804 A at 480 V. Size the breaker at 125% of the 400 V figure: that gives 2,706 A, which lands on a 4,000 A frame.

What does a 1500 kVA generator weigh?

Weight depends on the engine and alternator fitted, so we do not publish a single figure for this rating. The general arrangement drawing issued with your order carries the exact dry weight, the lifting points and the centre of gravity for the configuration you buy — ask for it for the engine you are considering before you design the plant room.

How much fuel does a 1500 kVA generator use per hour?

About 268.7 L/h at full 1200 kW load and 134.3 L/h at half load, on the ≤187 g/kWh basis used across this site. Consumption is close to linear with load in this class, so the fuel bill per kWh barely moves between 50% and 100% load.

Is 1500 kVA the same as 1200 kW?

At 0.8 power factor, yes — 1500 × 0.8 = 1200 kW. A lower site power factor reduces the usable kW further, so check the PF before confirming the rating.

What is the standby rating of this set?

1650 kVA / 1320 kW, which is 10% above prime. Standby is for loss of mains only and is rated at 200 hours a year; if the set runs as the main supply, specify it at prime instead.

Can two 1500 kVA sets run in parallel?

Yes, with the DSE8610 controller, matching alternator pitch and a synchronising panel. Two sets give 3000 kVA total, or N+1 redundancy at 1500 kVA. Specify it at the quote stage — retro-fitting is expensive.

Which engine platform should I choose?

At 1500 kVA the platform is fixed with the order rather than chosen from a list. MTU 4000 and Cummins QSK60 have the deepest service network for large standby plant; Perkins 4000 is competitive on price with good parts coverage in Africa and the Middle East. Send the load schedule and we will quote two or three options side by side.

What noise level should I expect?

65–75 dB(A) at 7 m for a canopied set, depending on acoustic grade. Residential-grade units sit at the low end; standard export canopies at the high end. Open skid sets are not normally specified where noise matters.

Send the load schedule, get a firm FOB price

Running kW, largest motor, duty and destination port — we will confirm the engine option, the tank size and the canopy grade, and price it landed-ready.