NFPA 20 Compliant | 20-2000 kW | Reliable Emergency Power for Fire Protection Systems
UL-listed and NFPA 20 compliant generator sets designed specifically for fire pump applications. Automatic start, rapid load acceptance, and redundant safety features ensure your fire protection system never fails.
Meets all NFPA 20 requirements for fire pump drivers including automatic start within 10 seconds, 100% load acceptance in one step, and dedicated fire pump service.
Automatic transfer switch (ATS) with less than 10-second transfer time. Engine starts automatically upon loss of normal power or fire alarm signal activation.
Dual fuel supply options, overspeed protection, high-temperature shutdown bypass, and unlimited run time capability for sustained fire fighting operations.
| Parameter | Specification |
|---|---|
| Power Range | 20 kW – 2000 kW (25 kVA – 2500 kVA) |
| Engine Brands | Cummins, Perkins, Volvo, SDEC, Yuchai, Weichai |
| Voltage | AC 400/230V (3-phase), 480/277V available |
| Frequency | 50 Hz / 60 Hz |
| Starting Time | < 10 seconds (NFPA 20 compliant) |
| Load Acceptance | 100% in one step |
| Fuel Type | Diesel / Natural Gas (dual fuel available) |
| Enclosure | Silent canopy (≤75dB@7m) or Open type |
| Compliance | NFPA 20, UL 2200, CE, ISO 8528, GB 6245 |
| ATS | Automatic Transfer Switch included (optional manual bypass) |
| Fuel Tank | Base tank (8hr runtime) or external tank available |
| Control Panel | Deep Sea / ComAp / SmartGen with auto-start |
| Ambient Temp | Standard: up to 40°C; Tropical: up to 50°C |
| Altitude | Standard: ≤1000m; Derating above 1000m |
Dedicated fire pump power for commercial towers, residential high-rises, and mixed-use developments with automatic mains failure sensing.
Reliable fire protection for factories, warehouses, chemical plants, and manufacturing facilities with hazardous area options.
Critical infrastructure fire pump systems with redundancy, remote monitoring, and 24/7 standby capability.
A fire pump genset is sized to the pump curve at 150% of rated flow, not to the building load — which is why a fire pump set often looks oversized against the rest of the electrical design. NFPA 20 also fixes the starting method, the fuel supply and the weekly test routine. Send the pump curve and the voltage, and as a fire pump generator supplier we quote the set with the correct overload rating, the CIF price and the test documentation your authority having jurisdiction will ask for.
Our engineers will design a NFPA-compliant fire pump power system tailored to your building code requirements.