>
SAME DAY SHIPPING ON ALL STOCKED PRODUCTS
86-0769-89610677 / 86-13553838770 | info@jinjiadongli.com
Sourcing in kVA? Our full kVA range runs 50–625 kVA prime, with a kVA-to-kW conversion table and sizing guide — see the kVA generator range →
Industrial Generators

INDUSTRIAL GENERATORS

Heavy Duty Diesel Generators | 50-2000 kW | 24/7 Continuous Power | All Major Brands

Industrial Generator Sets

Heavy-duty industrial diesel generator sets engineered for demanding applications including manufacturing plants, mining operations, data centers, oil & gas facilities, and large-scale construction projects. Available in both standby and prime power configurations.

Heavy Duty Design

Industrial-grade components with reinforced base frames, heavy-duty radiators, and oversized fuel systems for 24/7 continuous operation in harsh environments.

Premium Engines

Cummins, Perkins, Volvo, MTU, SDEC, Yuchai engines with electronic governors, turbocharging, and after-cooling for maximum efficiency and reliability.

Smart Control

Deep Sea, ComAp, or SmartGen controllers with remote monitoring, automatic mains failure (AMF), load sharing, and GSM/GPRS telemetry options.

By Power Rating

50-200 kW
Industrial Generator 50-200kW
Compact Industrial
50-200 kW
REQUEST QUOTE
250-500 kW
Industrial Generator 250-500kW
Medium Industrial
250-500 kW
REQUEST QUOTE
600-1000 kW
Industrial Generator 600-1000kW
Large Industrial
600-1000 kW
REQUEST QUOTE
1200-2000 kW
Industrial Generator 1200-2000kW
Mega Industrial
1200-2000 kW
REQUEST QUOTE

Key Specifications

ParameterSpecification
Power Range50 kW – 2000 kW (63 kVA – 2500 kVA)
Engine BrandsCummins, Perkins, Volvo, MTU, SDEC, Yuchai, Weichai
Alternator BrandsStamford, Leroy Somer, Marathon, Mecc Alte
Voltage400/230V (3-phase), 480/277V, 208/120V available
Frequency50 Hz / 60 Hz
Usage ModeStandby (ESP) / Prime (PRP) / Continuous (COP)
Fuel TypeDiesel / Natural Gas / Biogas
EnclosureOpen frame / Silent canopy (≤75dB@7m) / Containerized
ControlDeep Sea DSE7320/8610, ComAp InteliSys, SmartGen
CoolingRadiator (standard) / Heat exchanger / Keel cooling
ComplianceISO 8528, CE, EPA Tier 3/4, EU Stage V

Industrial Applications

Mining & Quarrying

Dust-proof and high-altitude rated generators for mining operations, crushing plants, and conveyor systems in extreme conditions.

Data Centers

Tier III/IV rated backup power with redundant configurations, fast load acceptance, and 24/7 monitoring capability.

Sizing & Tier Guide →

Construction

Rugged generators for construction sites with dust, moisture, and vibration resistance. Available with trailer mounting for mobility.

Power Your Industrial Operation

From 50kW to 2000kW, we have the right generator solution for your industrial facility. Contact us for a custom power assessment.

GET A FREE QUOTE

Frequently Asked Questions

What power range do you offer?

50 kW – 2000 kW (63 kVA – 2500 kVA). The figure that matters is the one you size against, so tell us the standby kVA or the prime kW you need and we will quote the frame that matches it rather than the nearest catalogue page.

Which engine brands can you supply?

Cummins, Perkins, Volvo, MTU, SDEC, Yuchai, Weichai. The brand you choose is driven by spare parts support in your market rather than by output, so tell us the destination country and we will quote the option with the best service coverage there.

What alternator brands can you fit?

Stamford, Leroy Somer, Marathon, Mecc Alte. Brushless with an AVR is standard. Where the load includes a UPS or variable speed drives, ask for a 2/3 pitch winding and a PMG excitation system, because those two details decide whether the waveform stays clean.

What voltages are available?

400/230V (3-phase), 480/277V, 208/120V available. Voltage is fixed at order because it decides the alternator winding — a set built for one voltage cannot be converted to another in the field.

Do you supply both 50 Hz and 60 Hz sets?

50 Hz / 60 Hz. Frequency sets the engine speed, 1500 rpm at 50 Hz and 1800 rpm at 60 Hz, so the engine and alternator are matched at build rather than adjusted later.

What duty ratings are available?

Standby (ESP) / Prime (PRP) / Continuous (COP). Standby, prime and continuous are three different machines in everything but name, so size against the duty the set will actually run, not against the largest number on the sheet.

What fuel types are supported?

Diesel / Natural Gas / Biogas. Dual fuel and gas options change the engine, the governor and the derating curve, so confirm the fuel before the frame is fixed.

What enclosure options are available?

Open frame / Silent canopy (≤75dB@7m) / Containerized. The enclosure choice is driven by where the set sits: a plant room with its own ventilation does not need a canopy, and a set near a boundary usually does.

What control system is fitted?

Deep Sea DSE7320/8610, ComAp InteliSys, SmartGen. For parallel operation the controller changes, so state whether the set will run alone or as part of a plant when you order.

How is the set cooled?

Radiator (standard) / Heat exchanger / Keel cooling. Radiator cooling needs an air path sized for the heat rejection, so confirm the plant room ventilation before the set arrives rather than after.

What standards does the set comply with?

ISO 8528, CE, EPA Tier 3/4, EU Stage V. Confirm which of those your local authority actually adopts, because the listing that matters at inspection is the one written into your permit.

Industrial Genset: Prime Power vs Standby Changes Everything

A unit rated for standby duty cannot run prime power year-round — the derating is typically 10 to 15 percent, and ignoring it is the most common reason an industrial genset fails early. Tell us the duty cycle, the daily running hours and the load profile, and we quote the rating that will actually hold.

Our industrial genset range runs 50 kW to 2000 kW on Cummins, Perkins, Volvo, SDEC, Weichai and Yuchai engines. As an industrial generator supplier we assemble and load-bank test in-house, so parallel operation, remote radiator or containerised builds are quoted as line items rather than as a price uplift you cannot check.