Volvo Penta Powered Diesel Generator Sets
Each model lists the complete power chain: genset model standby / prime (kVA & kW) rated current genuine Volvo Penta engine with prime/standby kW Stamford alternator with kVA controller. Built on Volvo Penta TAD550–TWD1653 GE industrial engines.
| Genset Model | Genset Output @ 50 Hz | Engine | Alternator (Stamford) | Controller | |||
|---|---|---|---|---|---|---|---|
| StandbykVA / kW (ESP) | PrimekVA / kW (PRP) | CurrentA @ 400 V | Engine Model | Eng. P/Sprime / standby kW | |||
| 50–90 kW | |||||||
| JJV-80GF | 110kVA/88 kW | 100kVA/80 kW | 144.3 | TAD550GE Volvo | 76 / 84 | UCI274C 120 kVA | SmartGen HGM6110N |
| JJV-90GF | 124kVA/99.2 kW | 112kVA/90 kW | 162.4 | TAD551GE Volvo | 89 / 98 | UCI274D 135 kVA | SmartGen HGM6110N |
| 100–180 kW | |||||||
| JJV-112GF | 154kVA/123.2 kW | 140kVA/112 kW | 202.1 | TAD750GE Volvo | 113 / 127 | UCI274E 160 kVA | SmartGen HGM6110N |
| JJV-128GF | 176kVA/140.8 kW | 160kVA/128 kW | 230.9 | TAD752GE Volvo | 158 / 174 | UCI274G 180 kVA | SmartGen HGM6110N |
| JJV-160GF | 220kVA/176 kW | 200kVA/160 kW | 288.7 | TAD753GE Volvo | 175 / 194 | UCI274J 230 kVA | SmartGen HGM6110N |
| JJV-180GF | 248kVA/198.4 kW | 225kVA/180 kW | 324.8 | TAD754GE Volvo | 219 / 242 | UCD274K 250 kVA | SmartGen HGM6110N |
| 200–320 kW | |||||||
| JJV-200GF | 275kVA/220 kW | 250kVA/200 kW | 360.8 | TAD754GE Volvo | 219 / 242 | HCI444D 300 kVA | SmartGen HGM6110N |
| JJV-200GF | 275kVA/220 kW | 250kVA/200 kW | 360.8 | TAD754GE Volvo | 219 / 242 | HCI444D 300 kVA | SmartGen HGM6110N |
| JJV-220GF | 302kVA/241.6 kW | 275kVA/220 kW | 396.9 | TAD754GE Volvo | 219 / 242 | HCI444ES 325 kVA | SmartGen HGM6110N |
| JJV-280GF | 385kVA/308 kW | 350kVA/280 kW | 505.2 | TAD1351GE Volvo | 279 / 306 | HCI444F 400 kVA | SmartGen HGM6110N |
| JJV-300GF | 412kVA/329.6 kW | 375kVA/300 kW | 541.3 | TAD1352GE Volvo | 314 / 345 | HCI544C 500 kVA | SmartGen HGM6110N |
| JJV-320GF | 440kVA/352 kW | 400kVA/320 kW | 577.3 | TAD1354GE Volvo | 328 / 361 | HCI544C 500 kVA | SmartGen HGM6110N |
| 350–500 kW | |||||||
| JJV-350GF | 481kVA/384.8 kW | 438kVA/350 kW | 631.5 | TAD1355GE Volvo | 355 / 390 | HCI544C 500 kVA | SmartGen HGM6110N |
| JJV-350GF | 481kVA/384.8 kW | 438kVA/350 kW | 631.5 | TAD1355GE Volvo | 355 / 390 | HCI544C 500 kVA | SmartGen HGM6110N |
| JJV-400GF | 550kVA/440 kW | 500kVA/400 kW | 721.7 | TAD1650GE Volvo | 393 / 433 | HCI544D 550 kVA | SmartGen HGM6110N |
| JJV-440GF | 605kVA/484 kW | 550kVA/440 kW | 793.8 | TAD1651GE Volvo | 430 / 473 | HCI544E 610 kVA | SmartGen HGM6110N |
| JJV-500GF | 688kVA/550.4 kW | 625kVA/500 kW | 902.1 | TWD1652GE Volvo | 505 / 557 | HCI634G 810 kVA | SmartGen HGM6110N |
| 550–750 kW | |||||||
| JJV-550GF | 756kVA/604.8 kW | 688kVA/550 kW | 992.3 | TWD1653GE Volvo | 547 / 604 | HCI634G 810 kVA | SmartGen HGM6110N |
No model matches your filter. Try a shorter keyword or reset the filters.
Engines are sized with a power reserve over the alternator prime output (industry rule ≈ 1.05–1.22×). Every engine kW figure below is taken from the engine maker's published 1500 rpm / 50 Hz rating, not estimated.
Engine ratings: Volvo Penta official technical data. Alternator capacities: STAMFORD | AvK official ratings. Values for reference at ≤1000 m, ≤40 °C; final data follows the order contract.