Home › Volvo Generators › Technical Selection Table

Volvo Penta Powered Diesel Generator Sets

Volvo Genset Technical Selection Table — TAD / TWD Series

Each model lists the complete power chain: genset model standby / prime (kVA & kW) rated current genuine Volvo Penta engine with prime/standby kW Stamford alternator with kVA controller. Built on Volvo Penta TAD550–TWD1653 GE industrial engines.

18standard models 80–550 kWprime range 50 Hz / 1500 rpm400/230 V, PF 0.8 Volvo Penta + Stamfordgenuine brands
Genset Model Genset Output @ 50 Hz Engine Alternator (Stamford) Controller
StandbykVA / kW (ESP) PrimekVA / kW (PRP) CurrentA @ 400 V Engine Model Eng. P/Sprime / standby kW
50–90 kW
JJV-80GF110kVA/88 kW100kVA/80 kW144.3
TAD550GE
Volvo
76 / 84
UCI274C
120 kVA
SmartGen HGM6110N
JJV-90GF124kVA/99.2 kW112kVA/90 kW162.4
TAD551GE
Volvo
89 / 98
UCI274D
135 kVA
SmartGen HGM6110N
100–180 kW
JJV-112GF154kVA/123.2 kW140kVA/112 kW202.1
TAD750GE
Volvo
113 / 127
UCI274E
160 kVA
SmartGen HGM6110N
JJV-128GF176kVA/140.8 kW160kVA/128 kW230.9
TAD752GE
Volvo
158 / 174
UCI274G
180 kVA
SmartGen HGM6110N
JJV-160GF220kVA/176 kW200kVA/160 kW288.7
TAD753GE
Volvo
175 / 194
UCI274J
230 kVA
SmartGen HGM6110N
JJV-180GF248kVA/198.4 kW225kVA/180 kW324.8
TAD754GE
Volvo
219 / 242
UCD274K
250 kVA
SmartGen HGM6110N
200–320 kW
JJV-200GF275kVA/220 kW250kVA/200 kW360.8
TAD754GE
Volvo
219 / 242
HCI444D
300 kVA
SmartGen HGM6110N
JJV-200GF275kVA/220 kW250kVA/200 kW360.8
TAD754GE
Volvo
219 / 242
HCI444D
300 kVA
SmartGen HGM6110N
JJV-220GF302kVA/241.6 kW275kVA/220 kW396.9
TAD754GE
Volvo
219 / 242
HCI444ES
325 kVA
SmartGen HGM6110N
JJV-280GF385kVA/308 kW350kVA/280 kW505.2
TAD1351GE
Volvo
279 / 306
HCI444F
400 kVA
SmartGen HGM6110N
JJV-300GF412kVA/329.6 kW375kVA/300 kW541.3
TAD1352GE
Volvo
314 / 345
HCI544C
500 kVA
SmartGen HGM6110N
JJV-320GF440kVA/352 kW400kVA/320 kW577.3
TAD1354GE
Volvo
328 / 361
HCI544C
500 kVA
SmartGen HGM6110N
350–500 kW
JJV-350GF481kVA/384.8 kW438kVA/350 kW631.5
TAD1355GE
Volvo
355 / 390
HCI544C
500 kVA
SmartGen HGM6110N
JJV-350GF481kVA/384.8 kW438kVA/350 kW631.5
TAD1355GE
Volvo
355 / 390
HCI544C
500 kVA
SmartGen HGM6110N
JJV-400GF550kVA/440 kW500kVA/400 kW721.7
TAD1650GE
Volvo
393 / 433
HCI544D
550 kVA
SmartGen HGM6110N
JJV-440GF605kVA/484 kW550kVA/440 kW793.8
TAD1651GE
Volvo
430 / 473
HCI544E
610 kVA
SmartGen HGM6110N
JJV-500GF688kVA/550.4 kW625kVA/500 kW902.1
TWD1652GE
Volvo
505 / 557
HCI634G
810 kVA
SmartGen HGM6110N
550–750 kW
JJV-550GF756kVA/604.8 kW688kVA/550 kW992.3
TWD1653GE
Volvo
547 / 604
HCI634G
810 kVA
SmartGen HGM6110N

No model matches your filter. Try a shorter keyword or reset the filters.

Power definitions (ISO 8528)

  • PRP (Prime) — unlimited-hours base power; 10% overload for 1 h in every 12 h.
  • ESP (Standby) — emergency maximum, no overload (typically +10% over prime).
  • Rated current I = Prime kW / (√3 × 400 V), three-phase PF 0.8.

Engine-to-set matching

Engines are sized with a power reserve over the alternator prime output (industry rule ≈ 1.05–1.22×). Every engine kW figure below is taken from the engine maker's published 1500 rpm / 50 Hz rating, not estimated.

Configuration & options

  • Alternator: genuine Stamford, brushless, H-class, IP23, PF 0.8.
  • Controller: SmartGen HGM series standard; Deep Sea DSE6120/7320 on request.
  • Open / silent / super-silent / trailer types; ATS, parallel & remote-monitoring optional.

Data sources

Engine ratings: Volvo Penta official technical data. Alternator capacities: STAMFORD | AvK official ratings. Values for reference at ≤1000 m, ≤40 °C; final data follows the order contract.

Need a quoted datasheet or custom configuration?
Tell us the required kW, standby/base use and sound level — we reply with factory price & specs.

How to Read This Volvo Selection Table

Volvo Penta and Volvo CE industrial engines are the quietest and cleanest option in the 80–550 kW band. The TAD series meets EU Stage and EPA Tier emissions without after-treatment on most ratings, which matters in jurisdictions where a visible stack or a DEF tank is a planning problem.

If your noise limit is under 70 dB(A) at 7 m, or your permit requires a Tier 4 / Stage V engine, start here. The purchase price is higher than Weichai or SDEC at the same rating; the enclosure cost is usually lower because the engine is already quiet.

The table above lists Volvo genset ratings from 80–550 kW with the engine model, alternator frame and typical fuel consumption for each. Two columns decide most enquiries: the standby rating (what the set can carry for the duration of an outage) and the prime rating (what it can carry continuously). If you are comparing our table against another supplier's, check whether their figures are prime or standby — a standby rating quoted as prime is roughly 10 percent optimistic.

Jinjia Power is a diesel generator supplier and genset manufacturer in Dongguan, China, assembling every rating on this table in our own works and load-bank testing each unit at 100 percent rated output before shipment. Send the standby kVA you need, the voltage and frequency (50 or 60 Hz) and the destination port, and you get a firm quote inside one working day — engine model, alternator frame, controller, canopy grade and CIF price on one sheet. If the rating you need is not on the table, ask anyway: we build non-standard ratings as a normal option rather than a special order.

Frequently Asked Questions

What power range does this Volvo table cover?

It lists 18 models from 88 kW to 604 kW standby, with prime ratings from 80 kW to 550 kW. The table carries the TAD and TWD industrial series.

What is the difference between the standby and prime columns?

Standby is emergency duty with a varying load and no overload. Prime allows a 10 per cent overload for one hour in twelve and is the number to quote for continuous supply. Across this table standby averages about 1.10 times prime, so the same physical set carries two different numbers. Always state which one you are specifying against, because the price and the warranty follow the rating.

How is the current column calculated?

It is full-load line current at 400 V three phase, derived from the standby kVA: kVA times 1000 divided by root three times 400. Use it directly for cable and breaker sizing, then apply the derating for the ambient temperature and the installation method on site.

Why is the engine rated higher than the alternator?

The engine carries the alternator losses as well as the electrical load. On this table the margin runs from about 1.05 to 1.22 times depending on the frame. An engine matched exactly to the alternator rating has nothing left for altitude, high ambient or a heavy direct-on-line motor start.

What conditions are these ratings valid for?

1000 m altitude or below and 40 degrees C ambient, taken from the engine maker's and the alternator maker's published catalogues. Above that the set derates by roughly 1 per cent per 100 m and 2 to 3 per cent per 5 degrees C. Send the site conditions with the enquiry and the quoted figure will be the derated one.

Which controller is fitted?

SmartGen HGM420N on the smaller frames and HGM6110N or HGM6120N from roughly 100 kW upward. The controller is a specification item, not fixed — Deep Sea, ComAp or a specific paralleling panel can be built instead if the project standard names one.

Why is the Volvo range narrower than the others?

Because Volvo Penta builds industrial engines for a defined band rather than the full spread. This table covers 80 to 550 kW prime in 18 models. Below that the Volvo option is uneconomic against a Perkins or SDEC build, and above it the answer is normally a Mitsubishi, MTU or a Cummins CCEC frame. We would rather say that than stretch a small engine past its duty.

What does the TAD and TWD designation mean?

TAD is the smaller industrial family and TWD the larger, heavier one, both turbocharged and aftercooled. The TWD frames in this table run up to 550 kW prime. Both are the industrial range rather than the marine range, so the ratings are continuous-duty industrial figures rather than pleasure-craft figures.

Can a rating that is not on the table be quoted?

Yes. The table is the commonly built range. Different voltages, 60 Hz builds, marine duty engines, silent canopies, container packages and dual-bearing alternators are all normal variations. Give the duty, the site conditions and the voltage and the closest frame is quoted with the deviation listed.

How long is delivery and what is the minimum order?

Standard frames ship in 3 to 7 working days from the factory for a single set, longer for a containerised or paralleling package. There is no minimum order for a single genset. Sets leave from Shenzhen or Guangzhou port, and the export terms are normally 30 per cent deposit with the balance before shipment.