Genset Model Genset Output @ 50 Hz Engine Alternator (Stamford) Controller Mechanical Data
StandbykVA / kW (ESP) PrimekVA / kW (PRP) CurrentA @ 400 V Engine Model Eng. P/Sprime / standby kW Displ.LNoisedB(A) @7mWeight / Dims.
50–90 kW
KDGS66S83kVA/66.4 kW75kVA/60 kW108.3
4ZTAA3.5-G31
SDEC
74 / 81
UCI224G
85 kVA
SmartGen HGM6110N3.50≤85790 kg
1850×700×1300
KDGS70S87kVA/69.6 kW80kVA/64 kW115.5
4HTAA4.3-G33
SDEC
78 / 86
UCI274C
120 kVA
SmartGen HGM6110N4.30≤921050 kg
1950×900×1200
KDGS90S113kVA/90.4 kW100kVA/80 kW144.3
4HTAA4.3-G34
SDEC
95 / 105
UCI274C
120 kVA
SmartGen HGM6110N4.30≤921100 kg
1950×950×1200
KDGS100S125kVA/100 kW112kVA/89.6 kW161.7
4HTAA4.3-G35
SDEC
106 / 117
UCI274D
135 kVA
SmartGen HGM6110N4.30≤921110 kg
1950×950×1200
100–180 kW
KDGS120S150kVA/120 kW137kVA/109.6 kW197.7
4HTAA4.3-G36
SDEC
120 / 132
UCI274E
160 kVA
SmartGen HGM6110N4.30≤921150 kg
1950×950×1200
KDGS132S165kVA/132 kW150kVA/120 kW216.5
6HTAA6.5-G32
SDEC
140 / 155
UCI274G
180 kVA
SmartGen HGM6110N4.30≤951360 kg
2350×950×1375
KDGS150S187kVA/149.6 kW150kVA/120 kW216.5
6HTAA6.5-G35
SDEC
155 / 170
UCI274H
200 kVA
SmartGen HGM6110N4.30≤951360 kg
2350×950×1375
KDGS165S206kVA/164.8 kW187kVA/149.6 kW269.9
6HTAA6.5-G33
SDEC
168 / 185
UCI274J
230 kVA
SmartGen HGM6110N4.30≤951410 kg
2320×950×1375
KDGS180S225kVA/180 kW200kVA/160 kW288.7
6HTAA6.5-G34
SDEC
186 / 205
UCI274J
230 kVA
SmartGen HGM6110N4.30≤951440 kg
2320×950×1375
KDGS200S250kVA/200 kW225kVA/180 kW324.8
6DTAA8.9-G32
SDEC
208 / 228
UCD274K
250 kVA
SmartGen HGM6110N8.82≤961830 kg
2550×1000×1385
200–320 kW
KDGS220S275kVA/220 kW250kVA/200 kW360.8
6DTAA8.9-G33
SDEC
230 / 253
HCI444D
300 kVA
SmartGen HGM6110N8.82≤961950 kg
2550×1000×1470
KDGS250S312kVA/249.6 kW275kVA/220 kW396.9
6DTAA8.9-G34
SDEC
245 / 253
HCI444ES
325 kVA
SmartGen HGM6110N8.82≤961950 kg
2550×1000×1470
KDGS280S350kVA/280 kW312kVA/249.6 kW450.3
6ETAA11.8-G32
SDEC
280 / 308
HCI444E
350 kVA
SmartGen HGM6110N11.82≤972800 kg
3000×1250×1620
KDGS300S375kVA/300 kW350kVA/280 kW505.2
6ETAA11.8-G33
SDEC
307 / 338
HCI444FS
380 kVA
SmartGen HGM6110N11.82≤972550 kg
3100×1150×1620
KDGS330S412kVA/329.6 kW375kVA/300 kW541.3
6ETAA11.8-G31
SDEC
340 / 380
HCI544C
500 kVA
SmartGen HGM6110N11.82≤972800 kg
2950×1150×1620
KDGS360S450kVA/360 kW400kVA/320 kW577.3
6ETAA12.8-G32
SDEC
360 / 400
HCI544C
500 kVA
SmartGen HGM6110N12.82≤972700 kg
3100×1150×1620
350–500 kW
KDGS400S500kVA/400 kW450kVA/360 kW649.5
6ETAA12.8-G31
SDEC
401 / 441
HCI544C
500 kVA
SmartGen HGM6110N12.82≤972700 kg
3300×1150×1620
KDGS440S550kVA/440 kW500kVA/400 kW721.7
6ETAA12.8-G310
SDEC
450 / 495
HCI544D
550 kVA
SmartGen HGM6110N12.82≤973100 kg
3100×1300×1770
KDGS500S625kVA/500 kW562kVA/449.6 kW811.2
12GTAA27-G33
SDEC
505 / 555
HCI544FS
625 kVA
SmartGen HGM6110N26.60≤1034370 kg
3550×1690×2120
KDGS550S687kVA/549.6 kW625kVA/500 kW902.1
12GTAA27-G32
SDEC
565 / 622
HCI634G
810 kVA
SmartGen HGM6110N26.60≤1034550 kg
3400×1690×2120
550–750 kW
KDGS620S750kVA/600 kW700kVA/560 kW1010.3
12GTAA27-G31
SDEC
622 / 684
HCI634G
810 kVA
SmartGen HGM6110N26.60≤1034550 kg
3400×1690×2120
KDGS660S825kVA/660 kW750kVA/600 kW1082.5
6KTAA25-G32
SDEC
685 / 754
HCI634H
940 kVA
SmartGen HGM6110N25.20≤1125550 kg
3800×1640×2160
KDGS720S900kVA/720 kW825kVA/660 kW1190.8
6KTAA25-G31
SDEC
728 / 800
HCI634H
940 kVA
SmartGen HGM6110N25.20≤1125650 kg
3900×1640×2160
KDGS800S1000kVA/800 kW900kVA/720 kW1299
6KTAA25-G320
SDEC
820 / 902
S6L1D-C
1000 kVA
SmartGen HGM6110N25.20≤1126050 kg
4000×1750×2320
800–1000 kW
KDGS900S1125kVA/900 kW1000kVA/800 kW1443.3
6KTAA25-G321
SDEC
880 / 968
S6L1D-D
1125 kVA
SmartGen HGM6110N25.20≤1126250 kg
4000×1750×2320
KDGS1000S1250kVA/1000 kW1125kVA/900 kW1623.8
6WTAA35-G310
SDEC
1018 / 1120
S6L1D-E
1250 kVA
SmartGen HGM6110N35.10≤1188000 kg
4500×2080×2450
KDGS1100S1375kVA/1100 kW1250kVA/1000 kW1804.2
6WTAA35-G311
SDEC
1118 / 1230
S6L1D-F
1400 kVA
SmartGen HGM6110N35.10≤1188050 kg
4500×2080×2450
1100–1500 kW
KDGS1200S1500kVA/1200 kW1375kVA/1100 kW1984.6
12KTA58-G36
SDEC
1280 / 1410
S7L1D-C4
1550 kVA
SmartGen HGM6120N57.20≤11513550 kg
4500×2200×2515
KDGS1350S1688kVA/1350.4 kW1563kVA/1250.4 kW2255.9
12KTA58-G35
SDEC
1420 / 1560
S7L1D-E4
1750 kVA
SmartGen HGM6120N57.20≤11513970 kg
4500×2200×2515
KDGS1500S1875kVA/1500 kW1688kVA/1350.4 kW2436.3
12KTA58-G34
SDEC
1560 / 1720
S7L1D-F4
1900 kVA
SmartGen HGM6120N57.20≤11514430 kg
4600×2200×2515
KDGS1650S2063kVA/1650.4 kW1875kVA/1500 kW2706.3
12KTA58-G33
SDEC
1720 / 1890
S7L1D-G4
2080 kVA
SmartGen HGM6120N57.20≤11514770 kg
4600×2200×2515
≥1600 kW
KDGS1800S2250kVA/1800 kW2000kVA/1600 kW2886.7
12KTA58-G32
SDEC
1850 / 2035
S7L1D-H4
2250 kVA
SmartGen HGM6120N57.20≤11515090 kg
4700×2200×2515
KDGS2000S2500kVA/2000 kW2250kVA/1800 kW3247.5
12KTA58-G31
SDEC
2010 / 2210
S7L1D-J4
2500 kVA
SmartGen HGM6120N57.20≤11515260 kg
4700×2455×2515
KDGS2200S2750kVA/2200 kW2500kVA/2000 kW3608.3
16KTA76-G33
SDEC
2250 / 2500
S7/P80/S9 series (factory-engineered)
2750 kVA
SmartGen HGM6120N76.30≤12218200 kg
6400×2560×2900
KDGS2400S3000kVA/2400 kW2750kVA/2200 kW3969.2
16KTA76-G32
SDEC
2510 / 2780
S7/P80/S9 series (factory-engineered)
3000 kVA
SmartGen HGM6120N76.30≤12218500 kg
6400×2560×2900
KDGS2600S3250kVA/2600 kW3000kVA/2400 kW4330
16KTA76-G31
SDEC
2680 / 2950
S7/P80/S9 series (factory-engineered)
3250 kVA
SmartGen HGM6120N76.30≤12218900 kg
6500×2830×2900
KDGS2800S3500kVA/2800 kW3125kVA/2500 kW4510.4
16KTA76-G310
SDEC
2773 / —
S7/P80/S9 series (factory-engineered)
3500 kVA
SmartGen HGM6120N76.30≤12219100 kg
6600×2830×3430

No model matches your filter. Try a shorter keyword or reset the filters.

Power definitions (ISO 8528)

  • PRP (Prime) — unlimited-hours base power; 10% overload for 1 h in every 12 h.
  • ESP (Standby) — emergency maximum, no overload (typically +10% over prime).
  • Rated current I = Prime kW / (√3 × 400 V), three-phase PF 0.8.

Engine-to-set matching

Engines are sized with a power reserve over the alternator prime output (industry rule ≈ 1.05–1.22×). Every engine kW figure below is taken from the engine maker's published 1500 rpm / 50 Hz rating, not estimated.

Configuration & options

  • Alternator: genuine Stamford, brushless, H-class, IP23, PF 0.8.
  • Controller: SmartGen HGM series standard; Deep Sea DSE6120/7320 on request.
  • Open / silent / super-silent / trailer types; ATS, parallel & remote-monitoring optional.

Data sources

Engine ratings: SDEC (Shanghai Diesel Engine) official catalogue. Alternator capacities: STAMFORD | AvK official ratings. Values for reference at ≤1000 m, ≤40 °C; final data follows the order contract.

Need a quoted datasheet or custom configuration?
Tell us the required kW, standby/base use and sound level — we reply with factory price & specs.

How to Read This SDEC Selection Table

SDEC (Shanghai Diesel Engine Co.) is the value option that most first-time importers overlook. The Z, D, E and G series cover 60–3000 kW at a lower cost per kW than Cummins or Perkins, with a parts pipeline that runs through Shanghai rather than through a Western distributor. For a rental fleet or a price-driven tender, SDEC is usually the winning bid.

SDEC engines are Chinese-designed and Chinese-built. They are not Cummins copies, but they are also not Cummins — the service interval is shorter and the fuel system is less tolerant of contamination. If your site has clean fuel and a competent mechanic, the cost saving is real.

The table above lists SDEC genset ratings from 60–3000 kW with the engine model, alternator frame and typical fuel consumption for each. Two columns decide most enquiries: the standby rating (what the set can carry for the duration of an outage) and the prime rating (what it can carry continuously). If you are comparing our table against another supplier's, check whether their figures are prime or standby — a standby rating quoted as prime is roughly 10 percent optimistic.

Jinjia Power is a diesel generator supplier and genset manufacturer in Dongguan, China, assembling every rating on this table in our own works and load-bank testing each unit at 100 percent rated output before shipment. Send the standby kVA you need, the voltage and frequency (50 or 60 Hz) and the destination port, and you get a firm quote inside one working day — engine model, alternator frame, controller, canopy grade and CIF price on one sheet. If the rating you need is not on the table, ask anyway: we build non-standard ratings as a normal option rather than a special order.

Frequently Asked Questions

What power range does this SDEC table cover?

It lists 37 models from 66 kW to 2800 kW standby, with prime ratings from 60 kW to 2500 kW. SDEC is Shanghai Diesel, the value end of the Chinese engine market: simple, widely serviced and cheap to overhaul.

What is the difference between the standby and prime columns?

Standby is emergency duty with a varying load and no overload. Prime allows a 10 per cent overload for one hour in twelve and is the number to quote for continuous supply. Across this table standby averages about 1.10 times prime, so the same physical set carries two different numbers. Always state which one you are specifying against, because the price and the warranty follow the rating.

How is the current column calculated?

It is full-load line current at 400 V three phase, derived from the standby kVA: kVA times 1000 divided by root three times 400. Use it directly for cable and breaker sizing, then apply the derating for the ambient temperature and the installation method on site.

Why is the engine rated higher than the alternator?

The engine carries the alternator losses as well as the electrical load. On this table the margin runs from about 1.05 to 1.22 times depending on the frame. An engine matched exactly to the alternator rating has nothing left for altitude, high ambient or a heavy direct-on-line motor start.

What conditions are these ratings valid for?

1000 m altitude or below and 40 degrees C ambient, taken from the engine maker's and the alternator maker's published catalogues. Above that the set derates by roughly 1 per cent per 100 m and 2 to 3 per cent per 5 degrees C. Send the site conditions with the enquiry and the quoted figure will be the derated one.

Which controller is fitted?

SmartGen HGM420N on the smaller frames and HGM6110N or HGM6120N from roughly 100 kW upward. The controller is a specification item, not fixed — Deep Sea, ComAp or a specific paralleling panel can be built instead if the project standard names one.

Why choose SDEC over a European engine?

Price and parts access. An SDEC set typically lands 20 to 35 per cent below the equivalent Perkins or Volvo build, and the engine is simple enough that a workshop with basic diesel experience can service it. The trade-off is shorter overhaul intervals and a narrower dealer network outside Asia. For a rental fleet or a project where the client names no brand, it is usually the commercial answer.

What SDEC families are on the table?

The 4- and 6-cylinder D series at the bottom and the larger 6D and 12V frames up to 2500 kW prime. All are water-cooled, four-stroke, and all are genuine SDEC rather than a licensed copy, so parts come through the SDEC channel.

Can a rating that is not on the table be quoted?

Yes. The table is the commonly built range. Different voltages, 60 Hz builds, marine duty engines, silent canopies, container packages and dual-bearing alternators are all normal variations. Give the duty, the site conditions and the voltage and the closest frame is quoted with the deviation listed.

How long is delivery and what is the minimum order?

Standard frames ship in 3 to 7 working days from the factory for a single set, longer for a containerised or paralleling package. There is no minimum order for a single genset. Sets leave from Shenzhen or Guangzhou port, and the export terms are normally 30 per cent deposit with the balance before shipment.