MTU (Rolls-Royce) Powered Diesel Generator Sets
Each model lists the complete power chain: genset model standby / prime (kVA & kW) rated current genuine MTU engine with prime/standby kW Stamford alternator with kVA controller. Built on MTU 1600, 2000 and 4000 series engines for mission-critical and large-load applications.
| Genset Model | Genset Output @ 50 Hz | Engine | Alternator (Stamford) | Controller | |||
|---|---|---|---|---|---|---|---|
| StandbykVA / kW (ESP) | PrimekVA / kW (PRP) | CurrentA @ 400 V | Engine Model | Eng. P/Sprime / standby kW | |||
| 200–320 kW | |||||||
| JJM-220GF | 302kVA/241.6 kW | 275kVA/220 kW | 396.9 | 6R1600G10F MTU | 249 / 274 | HCI444ES 325 kVA | SmartGen HGM6110N |
| JJM-250GF | 344kVA/275.2 kW | 312kVA/250 kW | 451 | 6R1600G20F MTU | 274 / 301 | HCI444E 350 kVA | SmartGen HGM6110N |
| JJM-300GF | 412kVA/329.6 kW | 375kVA/300 kW | 541.3 | 8V1600G10F MTU | 325 / 358 | HCI544C 500 kVA | SmartGen HGM6110N |
| JJM-320GF | 440kVA/352 kW | 400kVA/320 kW | 577.3 | 8V1600G20F MTU | 358 / 394 | HCI544C 500 kVA | SmartGen HGM6110N |
| 350–500 kW | |||||||
| JJM-360GF | 495kVA/396 kW | 450kVA/360 kW | 649.5 | 10V1600G10F MTU | 407 / 448 | HCI544C 500 kVA | SmartGen HGM6110N |
| JJM-400GF | 550kVA/440 kW | 500kVA/400 kW | 721.7 | 10V1600G20F MTU | 448 / 493 | HCI544D 550 kVA | SmartGen HGM6110N |
| JJM-480GF | 660kVA/528 kW | 600kVA/480 kW | 866 | 12V1600G10F MTU | 524 / 576 | HCI544F 670 kVA | SmartGen HGM6110N |
| JJM-500GF | 688kVA/550.4 kW | 625kVA/500 kW | 902.1 | 12V1600G20F MTU | 576 / 634 | HCI634G 810 kVA | SmartGen HGM6110N |
| JJM-500GF | 688kVA/550.4 kW | 625kVA/500 kW | 902.1 | 12V1600G20F MTU | 576 / 634 | HCI634G 810 kVA | SmartGen HGM6110N |
| 550–750 kW | |||||||
| JJM-550GF | 756kVA/604.8 kW | 688kVA/550 kW | 992.3 | 12V2000G25 MTU | 580 / 635 | HCI634G 810 kVA | SmartGen HGM6110N |
| JJM-630GF | 866kVA/692.8 kW | 788kVA/630 kW | 1136.6 | 12V2000G65 MTU | 695 / 765 | HCI634H 940 kVA | SmartGen HGM6110N |
| 800–1000 kW | |||||||
| JJM-800GF | 1100kVA/880 kW | 1000kVA/800 kW | 1443.3 | 16V2000G25 MTU | 810 / 890 | S6L1D-D 1125 kVA | SmartGen HGM6110N |
| JJM-880GF | 1210kVA/968 kW | 1100kVA/880 kW | 1587.7 | 16V2000G65 MTU | 890 / 975 | S6L1D-E 1250 kVA | SmartGen HGM6110N |
| JJM-1000GF | 1375kVA/1100 kW | 1250kVA/1000 kW | 1804.2 | 18V2000G65 MTU | 1000 / 1100 | S6L1D-F 1400 kVA | SmartGen HGM6110N |
| JJM-1000GF | 1375kVA/1100 kW | 1250kVA/1000 kW | 1804.2 | 18V2000G65 MTU | 1000 / 1100 | S6L1D-F 1400 kVA | SmartGen HGM6110N |
| 1100–1500 kW | |||||||
| JJM-1100GF | 1512kVA/1209.6 kW | 1375kVA/1100 kW | 1984.6 | 12V4000G21R MTU | 1102 / — | S7L1D-C4 1550 kVA | SmartGen HGM6120N |
| JJM-1200GF | 1650kVA/1320 kW | 1500kVA/1200 kW | 2165 | 12V4000G23R MTU | 1205 / — | S7L1D-D4 1650 kVA | SmartGen HGM6120N |
| JJM-1400GF | 1925kVA/1540 kW | 1750kVA/1400 kW | 2525.8 | 12V4000G23 MTU | 1420 / 1575 | S7L1D-G4 2080 kVA | SmartGen HGM6120N |
| JJM-1500GF | 2062kVA/1649.6 kW | 1875kVA/1500 kW | 2706.3 | 12V4000G63 MTU | 1575 / 1750 | S7L1D-G4 2080 kVA | SmartGen HGM6120N |
| ≥1600 kW | |||||||
| JJM-1760GF | 2420kVA/1936 kW | 2200kVA/1760 kW | 3175.3 | 16V4000G23 MTU | 1798 / 1965 | S7L1D-J4 2500 kVA | SmartGen HGM6120N |
| JJM-1900GF | 2612kVA/2089.6 kW | 2375kVA/1900 kW | 3427.9 | 16V4000G63 MTU | 1965 / 2185 | S7/P80/S9 series (factory-engineered) 2612 kVA | SmartGen HGM6120N |
| JJM-2200GF | 3025kVA/2420 kW | 2750kVA/2200 kW | 3969.2 | 20V4000G23 MTU | 2200 / 2420 | S7/P80/S9 series (factory-engineered) 3025 kVA | SmartGen HGM6120N |
| JJM-2400GF | 3300kVA/2640 kW | 3000kVA/2400 kW | 4330 | 20V4000G63 MTU | 2420 / 2670 | S7/P80/S9 series (factory-engineered) 3300 kVA | SmartGen HGM6120N |
| JJM-2500GF | 3438kVA/2750.4 kW | 3125kVA/2500 kW | 4510.4 | 20V4000G63L MTU | 2590 / 2850 | S7/P80/S9 series (factory-engineered) 3438 kVA | SmartGen HGM6120N |
No model matches your filter. Try a shorter keyword or reset the filters.
Engines are sized with a power reserve over the alternator prime output (industry rule ≈ 1.05–1.22×). Every engine kW figure below is taken from the engine maker's published 1500 rpm / 50 Hz rating, not estimated.
Engine ratings: MTU (Rolls-Royce Power Systems) technical data sheets. Alternator capacities: STAMFORD | AvK official ratings. Values for reference at ≤1000 m, ≤40 °C; final data follows the order contract.
MTU is the top of the range and priced accordingly. The 1600, 2000 and 4000 series cover 220–2500 kW with the highest power density per litre of any engine on this site, which is why MTU sets are chosen when the plant room is small and the load is large — data centres, hospitals, and offshore installations where floor space is the binding constraint.
A 2000-series MTU delivers roughly the same output as a much larger displacement engine from another brand. If your constraint is footprint or weight rather than budget, this is the table to read.
The table above lists MTU genset ratings from 220–2500 kW with the engine model, alternator frame and typical fuel consumption for each. Two columns decide most enquiries: the standby rating (what the set can carry for the duration of an outage) and the prime rating (what it can carry continuously). If you are comparing our table against another supplier's, check whether their figures are prime or standby — a standby rating quoted as prime is roughly 10 percent optimistic.
Jinjia Power is a diesel generator supplier and genset manufacturer in Dongguan, China, assembling every rating on this table in our own works and load-bank testing each unit at 100 percent rated output before shipment. Send the standby kVA you need, the voltage and frequency (50 or 60 Hz) and the destination port, and you get a firm quote inside one working day — engine model, alternator frame, controller, canopy grade and CIF price on one sheet. If the rating you need is not on the table, ask anyway: we build non-standard ratings as a normal option rather than a special order.
It lists 24 models from 241 kW to 2750 kW standby, with prime ratings from 220 kW to 2500 kW. The table carries the 1600, 2000 and 4000 series.
Standby is emergency duty with a varying load and no overload. Prime allows a 10 per cent overload for one hour in twelve and is the number to quote for continuous supply. Across this table standby averages about 1.10 times prime, so the same physical set carries two different numbers. Always state which one you are specifying against, because the price and the warranty follow the rating.
It is full-load line current at 400 V three phase, derived from the standby kVA: kVA times 1000 divided by root three times 400. Use it directly for cable and breaker sizing, then apply the derating for the ambient temperature and the installation method on site.
The engine carries the alternator losses as well as the electrical load. On this table the margin runs from about 1.05 to 1.22 times depending on the frame. An engine matched exactly to the alternator rating has nothing left for altitude, high ambient or a heavy direct-on-line motor start.
1000 m altitude or below and 40 degrees C ambient, taken from the engine maker's and the alternator maker's published catalogues. Above that the set derates by roughly 1 per cent per 100 m and 2 to 3 per cent per 5 degrees C. Send the site conditions with the enquiry and the quoted figure will be the derated one.
SmartGen HGM420N on the smaller frames and HGM6110N or HGM6120N from roughly 100 kW upward. The controller is a specification item, not fixed — Deep Sea, ComAp or a specific paralleling panel can be built instead if the project standard names one.
MTU's three industrial families, in ascending size. The 1600 series covers roughly 275 to 700 kW, the 2000 series the middle band up to about 1400 kW, and the 4000 series the top of the table at 3125 kW prime. All are the Series 1600/2000/4000 industrial engines rather than the marine versions, so the ratings are industrial continuous figures.
When the project names it, or when the duty is genuinely severe: data centre standby, offshore, mining at altitude, or a site where the downtime cost dwarfs the engine price. The MTU costs more per kW than any other brand on this site and it earns that back in load acceptance and overhaul life. It is not the value option and we will not present it as one.
Yes. The table is the commonly built range. Different voltages, 60 Hz builds, marine duty engines, silent canopies, container packages and dual-bearing alternators are all normal variations. Give the duty, the site conditions and the voltage and the closest frame is quoted with the deviation listed.
Standard frames ship in 3 to 7 working days from the factory for a single set, longer for a containerised or paralleling package. There is no minimum order for a single genset. Sets leave from Shenzhen or Guangzhou port, and the export terms are normally 30 per cent deposit with the balance before shipment.