Home › MTU Generators › Technical Selection Table

MTU (Rolls-Royce) Powered Diesel Generator Sets

MTU Genset Technical Selection Table — 1600 / 2000 / 4000 Series

Each model lists the complete power chain: genset model standby / prime (kVA & kW) rated current genuine MTU engine with prime/standby kW Stamford alternator with kVA controller. Built on MTU 1600, 2000 and 4000 series engines for mission-critical and large-load applications.

24standard models 220–2500 kWprime range 50 Hz / 1500 rpm400/230 V, PF 0.8 MTU + Stamfordgenuine brands
Genset Model Genset Output @ 50 Hz Engine Alternator (Stamford) Controller
StandbykVA / kW (ESP) PrimekVA / kW (PRP) CurrentA @ 400 V Engine Model Eng. P/Sprime / standby kW
200–320 kW
JJM-220GF302kVA/241.6 kW275kVA/220 kW396.9
6R1600G10F
MTU
249 / 274
HCI444ES
325 kVA
SmartGen HGM6110N
JJM-250GF344kVA/275.2 kW312kVA/250 kW451
6R1600G20F
MTU
274 / 301
HCI444E
350 kVA
SmartGen HGM6110N
JJM-300GF412kVA/329.6 kW375kVA/300 kW541.3
8V1600G10F
MTU
325 / 358
HCI544C
500 kVA
SmartGen HGM6110N
JJM-320GF440kVA/352 kW400kVA/320 kW577.3
8V1600G20F
MTU
358 / 394
HCI544C
500 kVA
SmartGen HGM6110N
350–500 kW
JJM-360GF495kVA/396 kW450kVA/360 kW649.5
10V1600G10F
MTU
407 / 448
HCI544C
500 kVA
SmartGen HGM6110N
JJM-400GF550kVA/440 kW500kVA/400 kW721.7
10V1600G20F
MTU
448 / 493
HCI544D
550 kVA
SmartGen HGM6110N
JJM-480GF660kVA/528 kW600kVA/480 kW866
12V1600G10F
MTU
524 / 576
HCI544F
670 kVA
SmartGen HGM6110N
JJM-500GF688kVA/550.4 kW625kVA/500 kW902.1
12V1600G20F
MTU
576 / 634
HCI634G
810 kVA
SmartGen HGM6110N
JJM-500GF688kVA/550.4 kW625kVA/500 kW902.1
12V1600G20F
MTU
576 / 634
HCI634G
810 kVA
SmartGen HGM6110N
550–750 kW
JJM-550GF756kVA/604.8 kW688kVA/550 kW992.3
12V2000G25
MTU
580 / 635
HCI634G
810 kVA
SmartGen HGM6110N
JJM-630GF866kVA/692.8 kW788kVA/630 kW1136.6
12V2000G65
MTU
695 / 765
HCI634H
940 kVA
SmartGen HGM6110N
800–1000 kW
JJM-800GF1100kVA/880 kW1000kVA/800 kW1443.3
16V2000G25
MTU
810 / 890
S6L1D-D
1125 kVA
SmartGen HGM6110N
JJM-880GF1210kVA/968 kW1100kVA/880 kW1587.7
16V2000G65
MTU
890 / 975
S6L1D-E
1250 kVA
SmartGen HGM6110N
JJM-1000GF1375kVA/1100 kW1250kVA/1000 kW1804.2
18V2000G65
MTU
1000 / 1100
S6L1D-F
1400 kVA
SmartGen HGM6110N
JJM-1000GF1375kVA/1100 kW1250kVA/1000 kW1804.2
18V2000G65
MTU
1000 / 1100
S6L1D-F
1400 kVA
SmartGen HGM6110N
1100–1500 kW
JJM-1100GF1512kVA/1209.6 kW1375kVA/1100 kW1984.6
12V4000G21R
MTU
1102 / —
S7L1D-C4
1550 kVA
SmartGen HGM6120N
JJM-1200GF1650kVA/1320 kW1500kVA/1200 kW2165
12V4000G23R
MTU
1205 / —
S7L1D-D4
1650 kVA
SmartGen HGM6120N
JJM-1400GF1925kVA/1540 kW1750kVA/1400 kW2525.8
12V4000G23
MTU
1420 / 1575
S7L1D-G4
2080 kVA
SmartGen HGM6120N
JJM-1500GF2062kVA/1649.6 kW1875kVA/1500 kW2706.3
12V4000G63
MTU
1575 / 1750
S7L1D-G4
2080 kVA
SmartGen HGM6120N
≥1600 kW
JJM-1760GF2420kVA/1936 kW2200kVA/1760 kW3175.3
16V4000G23
MTU
1798 / 1965
S7L1D-J4
2500 kVA
SmartGen HGM6120N
JJM-1900GF2612kVA/2089.6 kW2375kVA/1900 kW3427.9
16V4000G63
MTU
1965 / 2185
S7/P80/S9 series (factory-engineered)
2612 kVA
SmartGen HGM6120N
JJM-2200GF3025kVA/2420 kW2750kVA/2200 kW3969.2
20V4000G23
MTU
2200 / 2420
S7/P80/S9 series (factory-engineered)
3025 kVA
SmartGen HGM6120N
JJM-2400GF3300kVA/2640 kW3000kVA/2400 kW4330
20V4000G63
MTU
2420 / 2670
S7/P80/S9 series (factory-engineered)
3300 kVA
SmartGen HGM6120N
JJM-2500GF3438kVA/2750.4 kW3125kVA/2500 kW4510.4
20V4000G63L
MTU
2590 / 2850
S7/P80/S9 series (factory-engineered)
3438 kVA
SmartGen HGM6120N

No model matches your filter. Try a shorter keyword or reset the filters.

Power definitions (ISO 8528)

  • PRP (Prime) — unlimited-hours base power; 10% overload for 1 h in every 12 h.
  • ESP (Standby) — emergency maximum, no overload (typically +10% over prime).
  • Rated current I = Prime kW / (√3 × 400 V), three-phase PF 0.8.

Engine-to-set matching

Engines are sized with a power reserve over the alternator prime output (industry rule ≈ 1.05–1.22×). Every engine kW figure below is taken from the engine maker's published 1500 rpm / 50 Hz rating, not estimated.

Configuration & options

  • Alternator: genuine Stamford, brushless, H-class, IP23, PF 0.8.
  • Controller: SmartGen HGM series standard; Deep Sea DSE6120/7320 on request.
  • Open / silent / super-silent / trailer types; ATS, parallel & remote-monitoring optional.

Data sources

Engine ratings: MTU (Rolls-Royce Power Systems) technical data sheets. Alternator capacities: STAMFORD | AvK official ratings. Values for reference at ≤1000 m, ≤40 °C; final data follows the order contract.

Need a quoted datasheet or custom configuration?
Tell us the required kW, standby/base use and sound level — we reply with factory price & specs.

How to Read This MTU Selection Table

MTU is the top of the range and priced accordingly. The 1600, 2000 and 4000 series cover 220–2500 kW with the highest power density per litre of any engine on this site, which is why MTU sets are chosen when the plant room is small and the load is large — data centres, hospitals, and offshore installations where floor space is the binding constraint.

A 2000-series MTU delivers roughly the same output as a much larger displacement engine from another brand. If your constraint is footprint or weight rather than budget, this is the table to read.

The table above lists MTU genset ratings from 220–2500 kW with the engine model, alternator frame and typical fuel consumption for each. Two columns decide most enquiries: the standby rating (what the set can carry for the duration of an outage) and the prime rating (what it can carry continuously). If you are comparing our table against another supplier's, check whether their figures are prime or standby — a standby rating quoted as prime is roughly 10 percent optimistic.

Jinjia Power is a diesel generator supplier and genset manufacturer in Dongguan, China, assembling every rating on this table in our own works and load-bank testing each unit at 100 percent rated output before shipment. Send the standby kVA you need, the voltage and frequency (50 or 60 Hz) and the destination port, and you get a firm quote inside one working day — engine model, alternator frame, controller, canopy grade and CIF price on one sheet. If the rating you need is not on the table, ask anyway: we build non-standard ratings as a normal option rather than a special order.

Frequently Asked Questions

What power range does this MTU table cover?

It lists 24 models from 241 kW to 2750 kW standby, with prime ratings from 220 kW to 2500 kW. The table carries the 1600, 2000 and 4000 series.

What is the difference between the standby and prime columns?

Standby is emergency duty with a varying load and no overload. Prime allows a 10 per cent overload for one hour in twelve and is the number to quote for continuous supply. Across this table standby averages about 1.10 times prime, so the same physical set carries two different numbers. Always state which one you are specifying against, because the price and the warranty follow the rating.

How is the current column calculated?

It is full-load line current at 400 V three phase, derived from the standby kVA: kVA times 1000 divided by root three times 400. Use it directly for cable and breaker sizing, then apply the derating for the ambient temperature and the installation method on site.

Why is the engine rated higher than the alternator?

The engine carries the alternator losses as well as the electrical load. On this table the margin runs from about 1.05 to 1.22 times depending on the frame. An engine matched exactly to the alternator rating has nothing left for altitude, high ambient or a heavy direct-on-line motor start.

What conditions are these ratings valid for?

1000 m altitude or below and 40 degrees C ambient, taken from the engine maker's and the alternator maker's published catalogues. Above that the set derates by roughly 1 per cent per 100 m and 2 to 3 per cent per 5 degrees C. Send the site conditions with the enquiry and the quoted figure will be the derated one.

Which controller is fitted?

SmartGen HGM420N on the smaller frames and HGM6110N or HGM6120N from roughly 100 kW upward. The controller is a specification item, not fixed — Deep Sea, ComAp or a specific paralleling panel can be built instead if the project standard names one.

What is the 1600, 2000 and 4000 series?

MTU's three industrial families, in ascending size. The 1600 series covers roughly 275 to 700 kW, the 2000 series the middle band up to about 1400 kW, and the 4000 series the top of the table at 3125 kW prime. All are the Series 1600/2000/4000 industrial engines rather than the marine versions, so the ratings are industrial continuous figures.

When is an MTU the right choice?

When the project names it, or when the duty is genuinely severe: data centre standby, offshore, mining at altitude, or a site where the downtime cost dwarfs the engine price. The MTU costs more per kW than any other brand on this site and it earns that back in load acceptance and overhaul life. It is not the value option and we will not present it as one.

Can a rating that is not on the table be quoted?

Yes. The table is the commonly built range. Different voltages, 60 Hz builds, marine duty engines, silent canopies, container packages and dual-bearing alternators are all normal variations. Give the duty, the site conditions and the voltage and the closest frame is quoted with the deviation listed.

How long is delivery and what is the minimum order?

Standard frames ship in 3 to 7 working days from the factory for a single set, longer for a containerised or paralleling package. There is no minimum order for a single genset. Sets leave from Shenzhen or Guangzhou port, and the export terms are normally 30 per cent deposit with the balance before shipment.