Home › MTU Generators › Technical Selection Table

MTU (Rolls-Royce) Powered Diesel Generator Sets

MTU Genset Technical Selection Table — 1600 / 2000 / 4000 Series

Each model lists the complete power chain: genset model standby / prime (kVA & kW) rated current genuine MTU engine with prime/standby kW Stamford alternator with kVA controller. Built on MTU 1600, 2000 and 4000 series engines for mission-critical and large-load applications.

24standard models 220–2500 kWprime range 50 Hz / 1500 rpm400/230 V, PF 0.8 MTU + Stamfordgenuine brands
Genset Model Genset Output @ 50 Hz Engine Alternator (Stamford) Controller
StandbykVA / kW (ESP) PrimekVA / kW (PRP) CurrentA @ 400 V Engine Model Eng. P/Sprime / standby kW
200–320 kW
JJM-220GF302kVA/241.6 kW275kVA/220 kW396.9
6R1600G10F
MTU
249 / 274
HCI444ES
325 kVA
SmartGen HGM6110N
JJM-250GF344kVA/275.2 kW312kVA/250 kW451
6R1600G20F
MTU
274 / 301
HCI444E
350 kVA
SmartGen HGM6110N
JJM-300GF412kVA/329.6 kW375kVA/300 kW541.3
8V1600G10F
MTU
325 / 358
HCI544C
500 kVA
SmartGen HGM6110N
JJM-320GF440kVA/352 kW400kVA/320 kW577.3
8V1600G20F
MTU
358 / 394
HCI544C
500 kVA
SmartGen HGM6110N
350–500 kW
JJM-360GF495kVA/396 kW450kVA/360 kW649.5
10V1600G10F
MTU
407 / 448
HCI544C
500 kVA
SmartGen HGM6110N
JJM-400GF550kVA/440 kW500kVA/400 kW721.7
10V1600G20F
MTU
448 / 493
HCI544D
550 kVA
SmartGen HGM6110N
JJM-480GF660kVA/528 kW600kVA/480 kW866
12V1600G10F
MTU
524 / 576
HCI544F
670 kVA
SmartGen HGM6110N
JJM-500GF688kVA/550.4 kW625kVA/500 kW902.1
12V1600G20F
MTU
576 / 634
HCI634G
810 kVA
SmartGen HGM6110N
JJM-500GF688kVA/550.4 kW625kVA/500 kW902.1
12V1600G20F
MTU
576 / 634
HCI634G
810 kVA
SmartGen HGM6110N
550–750 kW
JJM-550GF756kVA/604.8 kW688kVA/550 kW992.3
12V2000G25
MTU
580 / 635
HCI634G
810 kVA
SmartGen HGM6110N
JJM-630GF866kVA/692.8 kW788kVA/630 kW1136.6
12V2000G65
MTU
695 / 765
HCI634H
940 kVA
SmartGen HGM6110N
800–1000 kW
JJM-800GF1100kVA/880 kW1000kVA/800 kW1443.3
16V2000G25
MTU
810 / 890
S6L1D-D
1125 kVA
SmartGen HGM6110N
JJM-880GF1210kVA/968 kW1100kVA/880 kW1587.7
16V2000G65
MTU
890 / 975
S6L1D-E
1250 kVA
SmartGen HGM6110N
JJM-1000GF1375kVA/1100 kW1250kVA/1000 kW1804.2
18V2000G65
MTU
1000 / 1100
S6L1D-F
1400 kVA
SmartGen HGM6110N
JJM-1000GF1375kVA/1100 kW1250kVA/1000 kW1804.2
18V2000G65
MTU
1000 / 1100
S6L1D-F
1400 kVA
SmartGen HGM6110N
1100–1500 kW
JJM-1100GF1512kVA/1209.6 kW1375kVA/1100 kW1984.6
12V4000G21R
MTU
1102 / —
S7L1D-C4
1550 kVA
SmartGen HGM6120N
JJM-1200GF1650kVA/1320 kW1500kVA/1200 kW2165
12V4000G23R
MTU
1205 / —
S7L1D-D4
1650 kVA
SmartGen HGM6120N
JJM-1400GF1925kVA/1540 kW1750kVA/1400 kW2525.8
12V4000G23
MTU
1420 / 1575
S7L1D-G4
2080 kVA
SmartGen HGM6120N
JJM-1500GF2062kVA/1649.6 kW1875kVA/1500 kW2706.3
12V4000G63
MTU
1575 / 1750
S7L1D-G4
2080 kVA
SmartGen HGM6120N
≥1600 kW
JJM-1760GF2420kVA/1936 kW2200kVA/1760 kW3175.3
16V4000G23
MTU
1798 / 1965
S7L1D-J4
2500 kVA
SmartGen HGM6120N
JJM-1900GF2612kVA/2089.6 kW2375kVA/1900 kW3427.9
16V4000G63
MTU
1965 / 2185
S7/P80/S9 series (factory-engineered)
2612 kVA
SmartGen HGM6120N
JJM-2200GF3025kVA/2420 kW2750kVA/2200 kW3969.2
20V4000G23
MTU
2200 / 2420
S7/P80/S9 series (factory-engineered)
3025 kVA
SmartGen HGM6120N
JJM-2400GF3300kVA/2640 kW3000kVA/2400 kW4330
20V4000G63
MTU
2420 / 2670
S7/P80/S9 series (factory-engineered)
3300 kVA
SmartGen HGM6120N
JJM-2500GF3438kVA/2750.4 kW3125kVA/2500 kW4510.4
20V4000G63L
MTU
2590 / 2850
S7/P80/S9 series (factory-engineered)
3438 kVA
SmartGen HGM6120N

No model matches your filter. Try a shorter keyword or reset the filters.

Power definitions (ISO 8528)

  • PRP (Prime) — unlimited-hours base power; 10% overload for 1 h in every 12 h.
  • ESP (Standby) — emergency maximum, no overload (typically +10% over prime).
  • Rated current I = Prime kW / (√3 × 400 V), three-phase PF 0.8.

Engine-to-set matching

Engines are sized with a power reserve over the alternator prime output (industry rule ≈ 1.05–1.22×). Every engine kW figure below is taken from the engine maker's published 1500 rpm / 50 Hz rating, not estimated.

Configuration & options

  • Alternator: genuine Stamford, brushless, H-class, IP23, PF 0.8.
  • Controller: SmartGen HGM series standard; Deep Sea DSE6120/7320 on request.
  • Open / silent / super-silent / trailer types; ATS, parallel & remote-monitoring optional.

Data sources

Engine ratings: MTU (Rolls-Royce Power Systems) technical data sheets. Alternator capacities: STAMFORD | AvK official ratings. Values for reference at ≤1000 m, ≤40 °C; final data follows the order contract.

Need a quoted datasheet or custom configuration?
Tell us the required kW, standby/base use and sound level — we reply with factory price & specs.