250 kVA diesel generator set

250 kVA GENERATOR

JJP-M200GF — 250 kVA / 200 kW prime, 275 kVA / 220 kW standby. 361 A per phase at 400 V, 2800 × 1200 × 1700 mm, 1600 kg, 46.0 L/h at full load. FOB China US$14,000–20,000.

See the Full Specification
Other ratings in this range 100 kVA200 kVA250 kVA375 kVA500 kVAAll 50–625 kVA

250 kVA Generator — JJP-M200GF

Prime (PRP)
250 kVA
200 kW at 0.8 PF
Unlimited hours, 10% overload for 1 h in 12
Standby (ESP)
275 kVA
220 kW at 0.8 PF
Loss of mains only, 200 h/yr

250 kVA is the prime rating on the nameplate, not a rounded-up figure — the frame maps exactly onto the requirement. 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, three-phase four-wire, 0.8 power factor.

How Many Amps Is a 250 kVA Generator?

VoltagePhaseCurrent at 250 kVASuggested breaker frame
380 V3-phase380 A500 A
400 V3-phase361 A500 A
415 V3-phase348 A500 A
440 V3-phase328 A400 A
480 V3-phase301 A400 A
220 V1-phase1136 Aspecial winding
240 V1-phase1042 Aspecial winding

I = kVA × 1000 ÷ (√3 × V). Breaker sizing at 125% of the 400 V figure gives 451 A. Cable at 361 A needs roughly 2 × 120 mm² copper per phase for a run under 50 m. A single-phase 250 kVA set would need a bespoke alternator — balance the load across three phases instead.

Dimensions and Weight

ConfigurationL × W × HWeight
Open skid2800 × 1200 × 1700 mm1600 kg
Silent canopy3400 × 1800 × 2300 mm1780–1850 kg
With full baseframe tank—+250–400 kg depending on tank size

At 1600 kg the open set lifts with a forklift; the canopied version needs a crane or a heavy forklift. Allow 1 m clearance at the alternator end for cooling air and confirm canopy door swing on both long sides before siting. Cast a level concrete plinth rated for 1.5× the wet weight.

Fuel Consumption per Hour

LoadDiesel L/hUS gal/h
250 kVA / 200 kW (100%)46.0 L/h12.1
200 kVA / 160 kW36.8 L/h9.7
150 kVA / 120 kW27.6 L/h7.3
100 kVA / 80 kW18.4 L/h4.9
50 kVA / 40 kW9.2 L/h2.4

Based on ≤192 g/kWh at 835 g/L diesel density — about 0.184 L per kVA per hour at rated load. Consumption tracks load almost linearly in this class, so a set held at 50% for 12 hours a day burns roughly half the full-load figure for twice as long: the fuel bill per kWh barely changes, but the engine runs cleaner.

Fuel Tank Capacity and Runtime

Buyers ask for the tank capacity as often as they ask for the amps, and the two numbers are not independent: runtime is tank volume divided by consumption at the load you actually run. The baseframe tank is built to the order, so the right way to specify it is to start from the runtime you need.

Baseframe tankRuntime at full load (46.0 L/h)Runtime at 50% load (27.6 L/h)
300 L6.5 h10.9 h
400 L8.7 h14.5 h
500 L10.9 h18.1 h
600 L13.0 h21.7 h
800 L (silent canopy)17.4 h29.0 h

Tank volume is specified per order — the figures above are the standard options, not a fixed rating. A 250 kVA set at 50% load is the most common operating point for a hotel or office, and it stretches runtime almost exactly twice versus full load. If the site needs 12 hours unattended, specify 400 L rather than 300 L and confirm the tank is double-walled with a bund — single-wall baseframe tanks are not acceptable in most jurisdictions for a set above 200 kVA.

Engine Options on the 250 kVA Frame

BrandEngine modelStandby outputCylindersDisplacement
WeichaiWP10D238E200238 kW6-cyl9.7 L
CumminsNTA855-G1240 kW6-cyl14 L
Perkins1206A-E70TAG2210 kW6-cyl7 L
VolvoTAD731GE209 kW6-cyl7.2 L
YuchaiYC6A260-D20191 kW6-cyl7.3 L

Coupled to a Faraday FD3G-4 or Stamford HCI444 alternator, with a Deep Sea DSE7320 MKII controller as standard and DSE8610 for parallel operation. At 250 kVA the engine choice moves both price and serviceability — Cummins and Perkins have the widest parts network in Africa and the Middle East; Weichai and SDEC are the cost-competitive options with strong regional support; Volvo suits projects with emission or brand requirements. Note the Yuchai standby output: confirm the derate before specifying it for a continuous load.

What Can a 250 kVA Generator Power?

Hotel or office block
100–140 rooms, or 1,800–2,200 m² of office. Covers lighting, lifts, HVAC and kitchen on a single set without load shedding.
Light manufacturing
120–150 kW of connected machinery. Check the largest DOL motor against the 10% overload window — starting current, not running load, decides the rating.
Small hospital or clinic
60–100 beds with theatre and cold chain on essential circuits. Usually paired with an ATS and a dedicated essential board.
Telecom macro site
10–15 cabinets plus rectifiers and cooling. Parallel-ready with DSE8610 where the operator needs N+1.
Construction site
Tower crane, welders, concrete pump and site cabins. Specify the canopy and lifting frame here — sites move the set between phases.
Cold store or food plant
Compressors restart on transfer, the hardest load in the building. Size the alternator for the block load, not just the continuous rating.

What Does a 250 kVA Generator Cost?

Open-skid JJP-M200GF sets run US$14,000–20,000 FOB China. Engine brand moves that band more than anything else — Cummins and Perkins sit at the top, Weichai and SDEC at the bottom. A sound-attenuated canopy adds 8–12% and about 200 kg. Budget separately for a 500 A breaker, an ATS if the site needs automatic transfer, a synchronising panel if two sets run in parallel, and freight. Local market prices in India, Pakistan, Nigeria and South Africa usually run 40–80% above FOB once duty, inland freight and dealer margin are added — compare like for like before quoting a landed figure.

250 kVA Generator Questions

How many amps does a 250 kVA generator deliver?

361 A per phase at 400 V three-phase, 380 A at 380 V, 348 A at 415 V, 301 A at 480 V. Size the breaker at 125% of the 400 V figure.

What does a 250 kVA generator weigh?

1600 kg on an open skid, 2800 × 1200 × 1700 mm. The silent canopy adds 180–250 kg and 300 mm per dimension, giving about 1780–1850 kg before fuel.

How much fuel does a 250 kVA generator use per hour?

46.0 L/h at full 250 kVA load, 27.6 L/h at 50% load. That is 0.184 L per kVA per hour — consumption is close to linear with load in this class.

Is 250 kVA the same as 200 kW?

At 0.8 power factor, yes — 250 × 0.8 = 200 kW. A lower site power factor reduces the usable kW further, so check the PF before confirming the rating.

Can two 250 kVA sets run in parallel?

Yes, with the DSE8610 controller, matching alternator pitch and a synchronising panel. Two sets give 500 kVA total, or N+1 redundancy at 250 kVA. Specify it at the quote stage — retro-fitting is expensive.

Which engine brand should I choose?

Cummins and Perkins for parts availability across Africa and the Middle East; Weichai and SDEC for cost with strong regional support; Volvo where emissions or brand specification matter; Yuchai only where its lower standby output still clears the load.

What noise level should I expect?

65–75 dB(A) at 7 m for the canopied set, depending on acoustic grade. Residential-grade units sit at the low end; standard export canopies at the high end.

Single phase or three phase?

Three-phase is standard at this rating. A single-phase 250 kVA set needs a specially wound alternator and is rarely economic above 50 kVA — split the load across three phases instead.

Send the load schedule, get a firm FOB price

Running kW, largest motor, duty and destination port — we will confirm the engine option, the tank size and the canopy grade, and price it landed-ready.