TECHNICAL SUPPORT
Expert Support for Your Power Generation Needs
Phone Support
Call us at +86 135-5383-8770
Mon-Sat 8:00-18:00 CST
Email Support
info@jinjiadongli.com
24-hour response time
Remote Support
Remote diagnostics available
For authorized dealers
Technical Documentation
We provide comprehensive technical documentation for all our products, including operation manuals, service manuals, wiring diagrams, and parts catalogs. Contact our technical support team to request documentation for your specific generator model.
Installation Support
Our team can provide installation guidance and support for your generator set. Proper installation is critical for reliable operation and safety. We offer detailed installation manuals and can arrange on-site technical support for large projects.
Warranty Service
All Jinjia Power generators come with a comprehensive warranty. Our warranty covers manufacturing defects and ensures you get the support you need. Contact our service team for warranty claims and service support.
Before You Call: Four Faults That Cover Most Breakdowns
A generator that will not run is usually not a broken generator. In our experience of supporting sets in the field, more than half of the calls that reach us end with a cause that is outside the machine — fuel, air, battery or cooling. Working through the four patterns below takes fifteen minutes and settles the question of whether you need a technician at all.
The set will not crank
If the controller lights up but the engine does not turn, the fault is in the starting circuit. Check the battery terminal voltage under load rather than at rest: a battery that reads 12.6 V open-circuit can collapse to 8 V the moment the starter engages, and the controller will report a fail-to-start without ever saying the battery was flat.
After the battery, check the emergency stop. A set that has been stopped on the red button will not crank until the button is released and the controller is reset, and this is the single most common reason a set is reported dead on a Monday morning. Then check the start relay, the starter solenoid and the earth strap between engine and chassis — a corroded strap gives exactly the same symptom as a flat battery.
The set cranks but does not fire
Cranking without firing is a fuel problem in almost every case. Air in the fuel line after a filter change or a run-dry is the usual cause: the engine turns, the injection pump delivers nothing but foam, and no amount of cranking will clear it without bleeding at the filter head and at the injection pump.
If the fuel system is bled and the set still does not fire, check the fuel shut-off solenoid on the injection pump. It is a small coil that must be energised for fuel to pass, and it fails more often than any other component in the fuel circuit. A quick test is to listen for the click when the controller is switched to run.
The set starts and stops within seconds
A set that fires and then shuts down is being stopped deliberately by its own protection. The controller display will tell you which one, and the answer is one of four: low oil pressure, high engine temperature, overspeed, or charge failure.
Low oil pressure on a cold start is often a sender fault rather than a real pressure problem, particularly if the set runs for the same number of seconds every time before stopping. High temperature immediately after start points to a coolant level problem or an airlock. Overspeed on a set that sounds normal points to a governor or magnetic pickup issue. Charge failure means the alternator belt or the charging alternator itself.
The set runs but the output is wrong
Voltage that is low, high or unstable while the engine runs steadily is an excitation problem, and the automatic voltage regulator is the first suspect. Frequency that wanders is a governor problem, and frequency that reads exactly zero while the engine runs is a lost sensing signal or a blown voltage transformer fuse.
Before replacing an AVR, check the sensing leads and the fuse. A loose sense wire gives the same symptom as a failed regulator, and swapping the regulator without finding the loose wire will destroy the new one within minutes.
What We Need From You to Diagnose a Fault
A support engineer with the right four pieces of information can usually name the fault before the call ends. Without them the conversation becomes a guessing game and the set stays down for another day.
The nameplate photograph
One clear photo of the set nameplate gives us the model, the serial number, the rating, the voltage and frequency, and the date of manufacture. It tells us which engine and which alternator are fitted, which decides the spare parts, the manual version and the wiring diagram. Without the serial number we can only speak in generalities.
The controller display
Photograph the controller screen while the fault is showing. The fault code and the pre-alarm text are specific, and the difference between "low oil pressure" and "low oil pressure shutdown" tells us whether the set tripped or merely warned. If the controller has an event log, read out the last ten entries — the fault that stopped the set is often the second entry, not the first.
The history
Three questions: how many hours on the clock, when was the last service, and what changed immediately before the fault. A set that fails at 250 hours after a service has a different cause from one that fails at 8,000 hours with no service record. "What changed" catches the fuel delivery, the new load, the electrician who rewired the changeover panel, and the storm that flooded the room.
Reading the Controller Before You Touch Anything
Modern controllers record more than most operators read. Two families dominate the sets we supply, and both store enough history to identify an intermittent fault that never appears while a technician is standing there.
Deep Sea controllers
The DSE range keeps an event log of the last hundred events with a timestamp and the engine hours at the time. Navigating to it from the front panel takes four button presses. The log distinguishes between a warning, a shutdown and an electrical trip, which matters because a warning that nobody reset becomes a shutdown two days later.
SmartGen controllers
The HGM range stores alarms with the same structure and adds a record of the last start attempt and its outcome. On a set with an intermittent fail-to-start, that record is the fastest route to the cause, because it shows whether the controller commanded a start and got no rotation, or never commanded a start at all.
The faults that actually matter
Five alarms account for most shutdowns: low oil pressure, high engine temperature, overspeed, underspeed and emergency stop. Everything else — low coolant level, charge failure, low fuel level, sensor failure — is a warning that becomes a shutdown only if the set is configured that way. Knowing which alarms on your set are latching and which are not is worth ten minutes with the manual.
Spare Parts: What to Keep on the Shelf
A set that is waiting for a filter costs more in downtime than the filter costs to stock. The list below is what we recommend an operator with one to five sets keeps on hand, ordered by how often it is needed rather than by price.
| Part | Why it is on the list | Stock level for 1–5 sets |
|---|---|---|
| Oil filter | Changed every service; a missed change is the cheapest way to destroy a bearing | 2 per set |
| Fuel filter and water separator | The first casualty of dirty fuel, which is common in every export market | 3 per set |
| Air filter | Dusty sites block it in weeks, and a blocked filter costs power quietly | 2 per set |
| Fan and charge belts | A broken belt stops the set within minutes and is a five-minute fix | 1 set per engine |
| Starting batteries | Fail at two to three years regardless of hours; the most common no-crank cause | 1 set per set |
| Fuel shut-off solenoid | Small, cheap, and the usual reason a set cranks without firing | 1 per engine |
| Water pump and thermostat | High-temperature shutdowns trace back here more often than to the radiator | 1 per engine where the site is remote |
| AVR | Voltage faults are the second most common electrical failure after the battery | 1 per alternator type |
| Pistons, liners, crankshaft | Needed only at overhaul; stocking them ties up money for years | Order at overhaul |
Warranty: What Is Covered and What Is Not
A warranty claim is settled on evidence, not on argument. Knowing what the warranty covers before a failure happens makes the claim faster and avoids the conversation nobody enjoys.
What is covered
Manufacturing defects, assembly defects and material defects — a casting that fails, a bearing that fails inside its design life, a wiring error made at the works, a component that fails without misuse. The warranty is on the set as supplied, and it runs from commissioning or from shipment depending on the terms of the order.
What voids a claim
Overload beyond the rated output, running without oil or coolant, missed services beyond the interval in the manual, fuel or lubricant outside the specification, unauthorised dismantling, and damage from water, fire or impact. Normal wear items — filters, belts, batteries, injector nozzles — are consumables and are not warranty items, which is why they belong on the shelf rather than in a claim.
The evidence we need
Nameplate photo, controller fault log, service records, the load the set was carrying when it failed, and photographs of the failed component before it is cleaned or dismantled. A failed part that has been wire-brushed cannot be assessed, and a claim without service records cannot be distinguished from a set that was never maintained.
Installation Faults That Look Like Machine Faults
A significant share of the sets returned to us as faulty turn out to be correctly built and badly installed. The machine is blamed because the machine is what stopped, but the cause is in the room around it.
Exhaust back pressure
A long exhaust run, too many bends, or a silencer sized for a smaller set raises back pressure until the engine cannot clear its cylinders. The symptoms are low power, black smoke and high exhaust temperature, all of which look like a fuel or turbo fault. The limit is in the engine manual and is usually expressed in kPa; it is measured, not estimated.
Ventilation and room temperature
A set in a small room with inadequate air changes will derate and eventually shut down on high temperature, and the radiator will be blamed. The check is simple: measure the air temperature at the radiator inlet while the set runs at full load. If the room is more than 5 °C above ambient, the ventilation is the fault.
Earthing and neutral arrangement
A set configured for a solidly earthed neutral connected to a system expecting an isolated neutral will nuisance-trip its earth leakage protection, and the fault will appear and disappear depending on which loads are running. The neutral link inside the alternator terminal box is the thing to check, and it must match the installation, not the factory default.
Fuel supply
A supply line that is too small, a lift pump that cannot draw from a tank two metres below, a return line that is blocked, or a tank breather that is plugged. All four produce a set that runs for a few minutes and then loses power, and all four look like an injection fault from the operator's side of the panel.
Remote Diagnostics: What Can and Cannot Be Done
Controllers with a communications port can be read remotely, which shortens diagnosis considerably when the site is in another country. What can be done depends entirely on what is connected at the site.
With a Modbus connection and an internet gateway, we can read live parameters, read the event log, change configuration settings and in some cases reset a latched fault. What we cannot do remotely is hear the engine, smell the exhaust, see a fuel leak, or measure anything with a meter. A remote session identifies the likely cause; it does not replace a technician with a toolbox.
For dealers and larger fleets we can set up a monitoring arrangement where the controller reports to a dashboard and alarms are raised before the set shuts down. That is worth doing on standby sets that nobody looks at until the day the power fails.
What to Send Us for a Support Request
Send these six items in one message and the first reply will usually contain a diagnosis rather than a request for more information.
- Nameplate photo — model, serial number, rating, voltage and frequency.
- Controller screen photo — taken while the fault is displayed.
- Event log — the last ten entries, or a photo of the log pages.
- Hours and service history — engine hours and the date of the last service.
- What changed — the load, the fuel, the wiring, the weather, or the person who worked on it.
- What you have already tried — so we do not ask you to repeat it.
If the set is down and the load is critical, say so in the first line. Those enquiries are handled ahead of routine ones, and a set that is carrying a hospital or a data room is treated differently from one on a construction site with a deadline three weeks away.
GET YOUR GENERATOR SOLUTION TODAY