Product Overview
The ASCO Series 300 is a UL 1008-listed automatic transfer switch built for commercial, institutional and light-industrial standby power. It monitors both the utility and the generator source and transfers the load automatically when the normal source falls outside acceptable limits, then returns it once the utility is restored and stable. This unit is rated 3000 A, 480V, 3-pole, NEMA 1, open transition. Typical loads are a main-tie-main arrangement, a large central utility plant, a data hall or an industrial process bus β installations where the transfer switch is engineered to order, coordinated with the service entrance equipment and frequently supplied with bypass isolation or delayed transition. The NEMA 1 enclosure is intended for indoor installation in a dry, protected space such as a mechanical room or an electrical closet. Terminations and footprint. Twelve conductors per pole from 1/0 AWG to 750 kcmil in the 38 in by 91 in by 72 in assembly, 1,430 to 1,495 lb β the largest rating in the Series 300 line. A 3,000 A transfer switch belongs to a hospital, a data hall or a process plant where the whole electrical service transfers, and it is engineered to order against the switchboard, the generator breakers and the coordination study at the same time. Expect a factory outline drawing, a shipping split and a rigging contractor. Service arrangement. This is a 480Y/277 V three-phase four-wire switch, the standard industrial and large-commercial service in North America: 480 V for motors, chillers and process equipment, 277 V for lighting, with the neutral bonded at the service and carried solid through the transfer switch. This is the voltage at which arc-flash energy climbs fastest, so the upstream coordination study matters more here than at 208 V. Neutral configuration. The neutral is switched β it opens and closes with the phase poles as one more pole. You need this when the generator is wired as a separately derived source with its own grounding electrode and its own main bonding jumper: leaving the neutral solid would tie the two grounding systems together through the neutral, put objectionable current on the grounding conductor and leave the generator frame at a potential above earth during a fault. It costs one more pole and one more set of contacts to maintain, but on a separately derived system it is not optional, and an inspector will look for it. Enclosure. The Type 1 cabinet is for indoor use in a dry, protected space β a mechanical room, an electrical closet, a plant room β where the only thing it has to keep out is incidental dust and the occasional touch. It is not rain-tight and not watertight: mounting one on an exterior wall, even under a soffit, invites water in through the door seam and the conduit knockouts, and the first sign is usually a rusted mechanism rather than a tripped breaker. If the switch has to live outdoors, the 3R version of the same rating is the one to order. Matching generator. At 480V with an 0.8 power factor this switch carries approximately 1995 kW of load (3000 A Γ 480V Γ β3 Γ 0.8 = 1995 kW, three-phase). Size the standby generator so that its standby rating meets or exceeds that figure, and confirm the generator's two-wire automatic-start contacts are compatible with the transfer switch controller. Controller. This unit carries the ASCO Group G controller: a 128 Γ 64 graphical LCD with switch-position, source-availability, common-alarm and not-in-auto indication. Transfer and re-transfer delays, engine cool-down and the in-phase transfer timer are all set from the membrane keypad rather than from DIP switches, with ranges up to 60 min 59 s. The Group G controller supports both open transition and delayed transition, and accessory 11BE adds RS-485 communication at 9,600β115,200 bps, a seven-period programmable exerciser and a 300-event log. Three-pole configuration. The three phase conductors are switched with a solid neutral. This is the standard arrangement where the neutral is bonded at the service and must not be opened by the transfer switch. Supply. Supplied as a genuine ASCO Power Technologies (Schneider Electric) unit, brand new and factory original, packed for export from our Dongguan warehouse. Ask us for the outline drawing, wiring diagram and data sheet for this exact catalog number.