86-0769-89610677 / 86-13553838770 | info@jinjiadongli.com
Home > TRANSFER SWITCHES > 3ATSA32600CG0C Series 300 - ASCO | Automatic, 2600 AMP
3ATSA32600CG0C Series 300 - ASCO | Automatic, 2600 AMP
3ATSA32600CG0C ASCO 2600 A3ATSA32600CG0C ASCO 2600 A3ATSA32600CG0C ASCO 2600 A3ATSA32600CG0C ASCO 2600 A3ATSA32600CG0C ASCO 2600 A

3ATSA32600CG0C Series 300 - ASCO | Automatic, 2600 AMP

3ATSA32600CG0C

Status: IN STOCK, Same day shipping Worldwide available | Brand New, Certified Factory Original

* Contact us for pricing and full specifications

πŸ“ž Get a Quote:86-13553838770
← Back to products

Specifications

Catalog Number3ATSA32600CG0C
SeriesASCO Series 300
Product TypeAutomatic Transfer Switch (ATS)
Ampere Rating2600 A
Number of Poles3 Poles
Voltage Rating208V
Neutral ConfigurationSolid Neutral
Frequency50 / 60 Hz
EnclosureNEMA 1 (Indoor)
Transition TypeOpen Transition
ControllerGroup G
CertificationUL 1008 Listed
Applicable StandardNEC / NFPA 70 Articles 700, 701 and 702
Generator CompatibilityTwo-wire automatic-start generators
Load Disconnect Contact5 A resistive at 30 VDC max / 100 mA at 5 VDC min
Communication (opt. 11BE)RS-485, 9,600–11,5200 bps, address 1–247
ManufacturerASCO Power Technologies (Schneider Electric)
AvailabilityIN STOCK β€” same-day shipping, worldwide
ConditionBrand New, Certified Factory Original
Warranty1 Year

Product Overview

The ASCO Series 300 is a UL 1008-listed automatic transfer switch built for commercial, institutional and light-industrial standby power. It monitors both the utility and the generator source and transfers the load automatically when the normal source falls outside acceptable limits, then returns it once the utility is restored and stable. This unit is rated 2600 A, 208V, 3-pole, NEMA 1, open transition. Typical loads are a main-tie-main arrangement, a large central utility plant, a data hall or an industrial process bus β€” installations where the transfer switch is engineered to order, coordinated with the service entrance equipment and frequently supplied with bypass isolation or delayed transition. The NEMA 1 enclosure is intended for indoor installation in a dry, protected space such as a mechanical room or an electrical closet. Terminations and footprint. The terminations step up to twelve conductors per pole from 1/0 AWG to 750 kcmil, in a 38 in by 91 in by 72 in assembly weighing 1,430 to 1,495 lb. Twelve conductors per phase is a different class of work: the lug stack is deep, the cable has to be grouped and trained in racks, and the enclosure is large enough to walk into from the front. Nothing about this installation is improvisable β€” the layout is fixed by the outline drawing and the pull is scheduled like a busway run. Service arrangement. This is a 208Y/120 V three-phase four-wire switch β€” the service found in office buildings, retail strips, clinics and small data rooms, where one panelboard feeds 208 V three-phase loads and 120 V receptacle circuits off a solid neutral. The neutral is not switched, because it is bonded at the service and opening it would defeat ground-fault sensing. Neutral configuration. The grounded conductor is solid: it runs straight through on a bolted neutral plate and is never opened. That is the correct choice when the transfer switch is not a separately derived source β€” the generator neutral is bonded to the same grounding electrode system as the utility, so the neutral is one continuous current-carrying conductor end to end and breaking it would serve no purpose. It is also the cheaper of the two arrangements and has one fewer set of moving contacts to inspect, which is why it is the default on most commercial retrofits where the existing service neutral is already bonded. Enclosure. The Type 1 cabinet is for indoor use in a dry, protected space β€” a mechanical room, an electrical closet, a plant room β€” where the only thing it has to keep out is incidental dust and the occasional touch. It is not rain-tight and not watertight: mounting one on an exterior wall, even under a soffit, invites water in through the door seam and the conduit knockouts, and the first sign is usually a rusted mechanism rather than a tripped breaker. If the switch has to live outdoors, the 3R version of the same rating is the one to order. Matching generator. At 208V with an 0.8 power factor this switch carries approximately 749 kW of load (2600 A Γ— 208V Γ— √3 Γ— 0.8 = 749 kW, three-phase). Size the standby generator so that its standby rating meets or exceeds that figure, and confirm the generator's two-wire automatic-start contacts are compatible with the transfer switch controller. Controller. This unit carries the ASCO Group G controller: a 128 Γ— 64 graphical LCD with switch-position, source-availability, common-alarm and not-in-auto indication. Transfer and re-transfer delays, engine cool-down and the in-phase transfer timer are all set from the membrane keypad rather than from DIP switches, with ranges up to 60 min 59 s. The Group G controller supports both open transition and delayed transition, and accessory 11BE adds RS-485 communication at 9,600–115,200 bps, a seven-period programmable exerciser and a 300-event log. Three-pole configuration. The three phase conductors are switched with a solid neutral. This is the standard arrangement where the neutral is bonded at the service and must not be opened by the transfer switch. Supply. Supplied as a genuine ASCO Power Technologies (Schneider Electric) unit, brand new and factory original, packed for export from our Dongguan warehouse. Ask us for the outline drawing, wiring diagram and data sheet for this exact catalog number.

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com

Jinjia Power, Quality Assured