3ATSB32600DG0M Series 300 - ASCO | Automatic, 2600 AMP
3ATSB32600DG0M ASCO 2600 A3ATSB32600DG0M ASCO 2600 A3ATSB32600DG0M ASCO 2600 A3ATSB32600DG0M ASCO 2600 A3ATSB32600DG0M ASCO 2600 A

3ATSB32600DG0M Series 300 - ASCO | Automatic, 2600 AMP

3ATSB32600DG0M

Status: IN STOCK, Same day shipping Worldwide available | Brand New, Certified Factory Original

* Contact us for pricing and full specifications

πŸ“ž Get a Quote:86-13553838770
← Back to products

Specifications

Catalog Number3ATSB32600DG0M
SeriesASCO Series 300
Product TypeAutomatic Transfer Switch (ATS)
Ampere Rating2600 A
Number of Poles3 Poles
Voltage Rating220V
Neutral ConfigurationSwitched Neutral
Frequency50 / 60 Hz
EnclosureNEMA 3R (Outdoor Rain-tight)
Transition TypeOpen Transition
ControllerGroup G
CertificationUL 1008 Listed
Applicable StandardNEC / NFPA 70 Articles 700, 701 and 702
Generator CompatibilityTwo-wire automatic-start generators
Load Disconnect Contact5 A resistive at 30 VDC max / 100 mA at 5 VDC min
Communication (opt. 11BE)RS-485, 9,600–11,5200 bps, address 1–247
ManufacturerASCO Power Technologies (Schneider Electric)
AvailabilityIN STOCK β€” same-day shipping, worldwide
ConditionBrand New, Certified Factory Original
Warranty1 Year

Product Overview

The ASCO Series 300 is a UL 1008-listed automatic transfer switch built for commercial, institutional and light-industrial standby power. It monitors both the utility and the generator source and transfers the load automatically when the normal source falls outside acceptable limits, then returns it once the utility is restored and stable. This unit is rated 2600 A, 220V, 3-pole, NEMA 3R, open transition. Typical loads are a main-tie-main arrangement, a large central utility plant, a data hall or an industrial process bus β€” installations where the transfer switch is engineered to order, coordinated with the service entrance equipment and frequently supplied with bypass isolation or delayed transition. The NEMA 3R enclosure is rain-tight and rated for outdoor mounting against a wall or on a pad, so the switch can sit next to an exterior generator without an additional weather shelter. Terminations and footprint. The terminations step up to twelve conductors per pole from 1/0 AWG to 750 kcmil, in a 38 in by 91 in by 72 in assembly weighing 1,430 to 1,495 lb. Twelve conductors per phase is a different class of work: the lug stack is deep, the cable has to be grouped and trained in racks, and the enclosure is large enough to walk into from the front. Nothing about this installation is improvisable β€” the layout is fixed by the outline drawing and the pull is scheduled like a busway run. Neutral configuration. The neutral is switched β€” it opens and closes with the phase poles as one more pole. You need this when the generator is wired as a separately derived source with its own grounding electrode and its own main bonding jumper: leaving the neutral solid would tie the two grounding systems together through the neutral, put objectionable current on the grounding conductor and leave the generator frame at a potential above earth during a fault. It costs one more pole and one more set of contacts to maintain, but on a separately derived system it is not optional, and an inspector will look for it. Enclosure. The Type 3R cabinet is rain-tight, not watertight: it is built for outdoor mounting against a wall or on a pad, with a hooded or sloped top that sheds water and a gasketed door that keeps driven rain out. What it does not do is keep out dust or hose spray, and the installation still has to do its part β€” conduit entries need drip loops or sealing hubs so water running down the conduit cannot track into the enclosure, and the mounting surface has to drain. A 3R unit on a north wall in a coastal yard will outlast three indoor units in the same spot, which is why it is the default for anything not under a roof. Matching generator. At 220V with an 0.8 power factor this switch carries approximately 499 kW of load (2600 A Γ— 220V Γ— 0.8 = 499.2 kW, single-phase two-wire). Size the standby generator so that its standby rating meets or exceeds that figure, and confirm the generator's two-wire automatic-start contacts are compatible with the transfer switch controller. Controller. This unit carries the ASCO Group G controller: a 128 Γ— 64 graphical LCD with switch-position, source-availability, common-alarm and not-in-auto indication. Transfer and re-transfer delays, engine cool-down and the in-phase transfer timer are all set from the membrane keypad rather than from DIP switches, with ranges up to 60 min 59 s. The Group G controller supports both open transition and delayed transition, and accessory 11BE adds RS-485 communication at 9,600–115,200 bps, a seven-period programmable exerciser and a 300-event log. Three-pole configuration. The three phase conductors are switched with a solid neutral. This is the standard arrangement where the neutral is bonded at the service and must not be opened by the transfer switch. Supply. Supplied as a genuine ASCO Power Technologies (Schneider Electric) unit, brand new and factory original, packed for export from our Dongguan warehouse. Ask us for the outline drawing, wiring diagram and data sheet for this exact catalog number.