BASLER DECS250N Digital AVR | Voltage Regulator | Jinjia Power

BASLER DECS250N Digital AVR - Digital Automatic Voltage Regulator for BASLER Alternators | OEM Replacement

DECS250N

Status: IN STOCK, Same day shipping Worldwide available |

* Contact us for pricing and full specifications

📞 Get a Quote:86-13553838770
← Back to products

Specifications

SKUDECS250N
BrandBASLER
Model NumberDECS250N
Regulator TypeDigital Automatic Voltage Regulator
Excitation SystemSelf-excited or PMG (power stage independent of generator output)
Sensing InputTrue RMS, single-phase or three-phase, 100 / 120 / 200 / 240 / 400 / 480 / 600 V class, under 1 VA per phase
Power InputSingle-phase or three-phase, 50-500 Hz, fed from generator terminals or PMG
Output Voltage32 Vdc / 63 Vdc / 125 Vdc nominal, six-thyristor negative forcing power stage
Continuous Field Current15 Adc continuous (20 Adc up to 55 degC)
Forcing CurrentUp to 30 Adc for 10 s on the 32 Vdc range
Field Resistance (Min)1.6 ohm (32 V) / 4.2 ohm (63 V) / 8.33 ohm (240 V) minimum
Regulation AccuracyBetter than +/-0.25 per cent
Response TimeOne cycle typical, forcing limited
Frequency Range50 / 60 Hz and 61-420 Hz wide-range input
Under-Frequency ProtectionProgrammable volts-per-hertz limiting with adjustable knee and slope
Voltage AdjustmentExternal voltage adjust via analogue input or raise / lower contacts
Paralleling / DroopReactive droop and reactive differential compensation, cross-current compensated
Build-Up VoltageBuilds up from residual voltage
Thermal DriftBetter than 0.01 per cent per degC
Operating Temperature-40 to +60 degC
Storage Temperature-40 to +85 degC
Protection FeaturesOver-excitation, under-excitation, minimum excitation, generator over and under voltage, loss of sensing, over-temperature
Compatible AlternatorsBasler, Stamford, Leroy Somer, Marathon and Marelli alternators with compatible field resistance
MountingPanel or terminal-box mount
Lifecycle StatusIn production
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 1 Year International Warranty
Warranty1 Year International Warranty

Product Overview

Position in the range. The DECS250N sits in the BASLER regulator family carrying the designation Digital Automatic Voltage Regulator. Its place is defined by the field current it can hold, 15 Adc continuous (20 Adc up to 55 degC), against the field resistance it can drive, 1.6 ohm (32 V) / 4.2 ohm (63, at Better than +/-0.25 per cent accuracy over -40 to +60 degC. Where a machine falls outside either of the first two figures, a different member of the same family is the correct answer rather than a workaround.

Excitation architecture. Self-excited or PMG (power stage independent of generator output). That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.

Sensing. True RMS, single-phase or three-phase, 100 / 120 / 200 / 240 / 400 / 480 / 600 V class, under 1 VA per phase. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.

Power stage and field drive. Power input Single-phase or three-phase, 50-500 Hz, fed from generator terminals or PMG, output 32 Vdc / 63 Vdc / 125 Vdc nominal, six-thyristor negative forcing power stage. Field current rating 15 Adc continuous (20 Adc up to 55 degC), forcing capability Up to 30 Adc for 10 s on the 32 Vdc range, field resistance window 1.6 ohm (32 V) / 4.2 ohm (63. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. A voltage that is correct at no load and low at full load is almost never an accuracy problem. It is a current limit, a resistance problem or a cable problem.

Accuracy and response. Better than +/-0.25 per cent steady-state accuracy, One cycle typical, forcing limited, thermal drift Better than 0.01 per cent per degC. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Take a photograph of the terminal block before removing anything. Wiring drawings for older machines are frequently wrong, and the photograph is the only reliable record.

Frequency behaviour. Rated for 50 / 60 Hz and 61-420 Hz wide-range input, with Programmable volts-per-hertz limiting with adjustable knee and slope. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. The most common cause of intermittent excitation loss is a crimp terminal that was never properly made. Wiggle the harness with the machine running before replacing anything.

Paralleling. Reactive droop and reactive differential compensation, cross-current compensated. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. If two identical sets behave differently on the same load, swap the regulators before swapping anything else. The result tells you which side of the machine the fault is on.

Protection built into the regulator. Over-excitation, under-excitation, minimum excitation, generator over and under voltage, loss of sensing, over-temperature. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. Where a spare is being held, hold the drawing with it. A board without its wiring diagram costs a shift of production time to install.

What it fits. Basler, Stamford, Leroy Somer, Marathon and Marelli alternators with compatible field resistance. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. A regulator is a closed loop with a slow plant attached, and the plant is a large inductance. That is why the stability adjustment exists and why it is set after, not before, the voltage is correct.

Field notes on this model. The DECS-250 is Basler's current-generation digital regulator and the official successor to the DECS-200. The power stage is a six-thyristor bridge with negative forcing, so it can pull the field down as well as push it up, which is what gives the fast recovery on a load rejection. Because excitation is fed from a separate single-phase or three-phase source or from a PMG, the field does not collapse when terminal voltage collapses during a close-up short circuit. Programmable logic, metering and trending are configured in BESTCOMSPlus over Ethernet or USB.

Where this board earns its place. The DECS250N is normally the answer when a BASLER machine has lost regulation and the original board is either unavailable or priced like a small car. What decides the fit is not the brand name on the cover but three numbers: the field resistance window, the continuous field current, and the sensing voltage the machine actually delivers at the AVR terminals. Get those three right and the regulator behaves; get any one of them wrong and the symptom usually looks like a mechanical fault rather than an electrical one.

Mounting orientation and cooling. Most AVR boards are convection cooled and assume the heatsink fins are vertical. Mounting a DECS250N flat on its back inside a sealed box shortens its life even though the ambient temperature reads acceptable, because the local air around the thyristor is far hotter than the box average.

Paralleling setup. With two sets on the bus, adjust droop until reactive load divides in proportion to machine rating, then check it again at half load. A droop setting that looks right at full load and wrong at half load is usually a CT ratio error rather than a regulator fault.

The forcing margin. A regulator that can only just hold rated voltage at rated load has no forcing margin left, and the machine will dip on every load step. The DECS250N is specified with a minimum field resistance of 1.6 ohm (32 V) / 4.2 ohm (63 V) / 8.33 ohm (240 V) minimum; staying comfortably above that minimum, rather than exactly at it, is what leaves the forcing margin that makes a set feel solid rather than merely adequate.

Voltage drifts with ambient temperature. If the voltage is correct cold and low hot, the thermal drift of the regulator and the temperature coefficient of the field are adding up in the same direction. The DECS250N is specified at Better than +/-0.25 per cent; a drift of a couple of per cent over a fifty degree swing is normal for an analogue board and is not a fault.

Before the order is placed. Confirm the alternator frame, the measured field resistance, the sensing voltage at rated speed, the excitation system (shunt, AREP, auxiliary winding or PMG) and the mounting footprint. Five answers, no guessing. Every wrong regulator order we see traces back to one of those five being assumed rather than measured.

Matching the board to the duty, not to the label. Two BASLER alternators of the same kVA can need different regulators if one is specified for motor starting and the other for a resistive load. The DECS250N is specified at Better than +/-0.25 per cent regulation accuracy, which is the number that matters when the load is a mix of drives and lighting. For a purely resistive load even a looser board is invisible to the customer, and paying for accuracy that nobody measures is the most common way money is wasted on a rebuild.

Earthing and shielding. The regulator reference is the machine frame. Bond the AVR mounting plate to the frame with a dedicated conductor rather than relying on the mounting screws, and earth the sensing cable shield at one end only. When a set shows a voltage that wanders slowly with no load change, the cause is usually a circulating current in the shield rather than a failing board.