BASLER SR8A Static AVR | Voltage Regulator | Jinjia Power

BASLER SR8A Static AVR - Static Automatic Voltage Regulator for BASLER Alternators | OEM Replacement

SR8A

Status: IN STOCK, Same day shipping Worldwide available |

* Contact us for pricing and full specifications

📞 Get a Quote:86-13553838770
← Back to products

Specifications

SKUSR8A
BrandBASLER
Model NumberSR8A
Regulator TypeStatic Automatic Voltage Regulator
Excitation SystemSelf-excited, shunt fed from the main stator
Sensing InputNEMA 120 / 208 / 240 / 416 / 480 / 600 V at 10 VA per phase; SR6A and SR9A are the 400 Hz versions
Power Input120 Vac at 840 VA (SR4A, SR6A) or 240 Vac at 1680 VA (SR8A, SR9A), 50 / 60 Hz or 400 Hz
Output Voltage63 Vdc on SR4A and SR6A, 125 Vdc on SR8A and SR9A
Continuous Field Current7 Adc continuous
Forcing Current10 Adc for 1 minute
Field Resistance (Min)9 ohm on 63 V units or 18-19 ohm on 125 V units, 400 ohm maximum
Regulation Accuracy+/-0.5 per cent on average voltage
Response TimeBetter than 17 ms
Frequency Range50 / 60 Hz on SR4A and SR8A, 400 Hz on SR6A and SR9A
Under-Frequency ProtectionNone built in, frequency compensation is external on the SR platform
Voltage Adjustment+/-10 per cent via an external potentiometer
Paralleling / DroopReactive droop, 5 A CT input at 25 VA
Build-Up VoltageBuilds up from residual voltage
Thermal Drift+/-0.5 per cent per 20 degC after a 20 minute warm-up
Operating Temperature-55 to +70 degC at 3.5 A, -55 to +55 degC at 7.0 A
Storage Temperature-65 to +100 degC
Protection FeaturesOver-excitation protection through the external limiter, integral fuse
Compatible AlternatorsLarge frame alternators, 500-3000 kVA
MountingPanel or terminal-box mount
Lifecycle StatusLegacy platform, still supported by the SR and SSR Retrofit kits
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 1 Year International Warranty
Warranty1 Year International Warranty

Product Overview

Short version. The SR8A is a Static Automatic Voltage Regulator. It supplies the exciter field, senses the alternator output and corrects the difference several times a second. Its rating is 7 Adc continuous, its field resistance window 9 ohm on 63 V units or 18-19, its accuracy +/-0.5 per cent, and it is intended for machines whose field winding sits inside that window. Read the rest of this page as the detail behind those three figures.

Excitation architecture. Self-excited, shunt fed from the main stator. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. Vibration kills more regulators than heat does. If a board has failed twice in the same machine, look at the mounting before looking at the supplier.

Sensing. NEMA 120 / 208 / 240 / 416 / 480 / 600 V at 10 VA per phase; SR6A and SR9A are the 400 Hz versions. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Counterfeit regulators are a real problem on the widely copied boards. Buy from a source that will state where the board was made.

Power stage and field drive. Power input 120 Vac at 840 VA (SR4A, SR6A) or 240 Vac at 1680 VA (SR8A, SR9A), 50 / 60 Hz or 400 Hz, output 63 Vdc on SR4A and SR6A, 125 Vdc on SR8A and SR9A. Field current rating 7 Adc continuous, forcing capability 10 Adc for 1 minute, field resistance window 9 ohm on 63 V units or 18-19. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Static accuracy is measured on a resistive load at constant frequency. Real loads and real governors are neither, so treat the figure as a comparison between boards rather than a promise.

Accuracy and response. +/-0.5 per cent steady-state accuracy, Better than 17 ms, thermal drift +/-0.5 per cent per 20 degC after a 20 minute warm-up. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. The cheapest diagnostic tool in excitation work is a DC ammeter in the field circuit. It turns a vague symptom into a number within seconds.

Frequency behaviour. Rated for 50 / 60 Hz on SR4A and SR8A, 400 Hz on SR6A and SR9A, with None built in, frequency compensation is external on the SR platform. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. If the machine will not hold voltage at all, disconnect the field and measure the sensing voltage first. That one reading separates a sensing fault from a field fault.

Paralleling. Reactive droop, 5 A CT input at 25 VA. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. An alternator that has been rewound needs its field resistance re-measured, because a rewind commonly moves it by ten to twenty per cent in either direction.

Protection built into the regulator. Over-excitation protection through the external limiter, integral fuse. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. If the machine will not hold voltage at all, disconnect the field and measure the sensing voltage first. That one reading separates a sensing fault from a field fault.

What it fits. Large frame alternators, 500-3000 kVA. Lifecycle status: Legacy platform, still supported by the SR and SSR Retrofit kits. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. On a machine that has been standing for months, check residual voltage before condemning anything: a winding that has lost its remanence will not build up on any regulator.

Field notes on this model. The Basler SR series is the classic static regulator: a magnetic amplifier front end with a silicon power stage in a ventilated steel case with screw terminals. It is still the reference AVR on a lot of large frame machines because it is repairable and because the terminals are big enough to take a real field cable. SR4A and SR8A are the 50 / 60 Hz units; SR6A and SR9A are 400 Hz versions for aircraft ground power and defence sets, and the two groups are not interchangeable.

Standby versus prime power. A standby set runs a few hundred hours a year and its regulator spends most of its life cold; a prime power set runs continuously and its regulator spends its life at operating temperature. The SR8A is rated for -55 to +70 degC at 3.5 A, -55 to +55 degC at 7.0 A, which is fine in both cases provided the terminal box has any ventilation at all. What changes between the two duties is the capacitor ageing inside the board, not the semiconductor, so a prime power machine should have the regulator inspected on a schedule rather than on failure.

Wiring practice that prevents most call-backs. Run the sensing leads as a twisted pair, separate from the field cables, and land them on the terminals the drawing names rather than on the ones that happen to be nearest. On a SR8A the sensing input draws very little current, which is exactly why it is vulnerable: a loose terminal adds resistance that the regulator reads as a voltage error and corrects by pushing the field up, so the machine runs hot and high for no visible reason.

Commissioning sequence. Start with the machine at rated speed, no load, and the field disconnected. Confirm the sensing voltage at the AVR terminals is inside the window the board expects, then connect the field with the voltage trim at minimum. Bring the trim up slowly and watch the field current, not the terminal voltage, because the terminal voltage will look correct long before the field current has stabilised on a cold winding.

The field resistance check. Measure the exciter field with the regulator disconnected and the machine stopped, then measure again after a run. Cold resistance is what the board sees at start-up; hot resistance is what it sees at full load. The SR8A is specified with a minimum of 9 ohm on 63 V units or 18-19 ohm on 125 V units, 400 ohm maximum, and the real question is not whether the measured value is above that figure but whether the forcing current at that resistance still reaches the level the alternator needs to recover from a load step.

Hunting or slow oscillation. Oscillation at one to three seconds period is a stability setting problem. Oscillation at a fraction of a second is usually a sensing problem, often a bad connection that makes the reference jump. Distinguishing between the two by ear is possible and saves a lot of time.

Part numbers are not interchangeable across suffixes. On this family the suffix carries the field current class, the sensing arrangement or the frequency band, and two boards that look identical in a photograph can be a hundred per cent different in rating. Quote the full model number including the suffix, and where the suffix is unclear send a photograph of the original board with the terminal markings visible.

What the customer is actually buying. When a regulator is quoted as a replacement, the buyer is not purchasing a circuit board. They are purchasing the certainty that the set will hold voltage on the next load step. On the SR8A that certainty comes from the combination of 7 Adc continuous continuous field current and the Better than 17 ms response, and it disappears the moment the field resistance drifts outside the window the board was set up for.

Wiring practice that prevents most call-backs. Run the sensing leads as a twisted pair, separate from the field cables, and land them on the terminals the drawing names rather than on the ones that happen to be nearest. On a SR8A the sensing input draws very little current, which is exactly why it is vulnerable: a loose terminal adds resistance that the regulator reads as a voltage error and corrects by pushing the field up, so the machine runs hot and high for no visible reason.