Status: IN STOCK, Same day shipping Worldwide available | Brand New, 1 Year International Warranty
* Contact us for pricing and full specifications
| SKU | GRT8-TH1 150A |
| Brand | GRAMEYER |
| Model Number | GRT8-TH1 150A |
| Regulator Type | Analogue Automatic Voltage Regulator, high current |
| Excitation System | Self-excited, shunt fed |
| Sensing Input | Single-phase sensing, 160-300 Vac or 320-600 Vac |
| Power Input | 170-300 Vac single-phase or two-phase, 50 / 60 Hz |
| Output Voltage | 76.5-126 Vdc |
| Continuous Field Current | 150 A continuous |
| Forcing Current | 210 A for 10 s |
| Field Resistance (Min) | 6-50 ohm |
| Regulation Accuracy | 0.5 per cent static |
| Response Time | Adjustable from 8 to 500 ms |
| Frequency Range | 50 / 60 Hz |
| Under-Frequency Protection | Adjustable under-frequency protection |
| Voltage Adjustment | Internal trim potentiometer |
| Paralleling / Droop | Reactive droop for parallel operation |
| Build-Up Voltage | Builds up from residual voltage |
| Thermal Drift | Low thermal drift |
| Operating Temperature | -20 to +60 degC |
| Storage Temperature | -40 to +85 degC |
| Protection Features | Under-frequency, over-excitation |
| Compatible Alternators | Large frame alternators, 1000 kVA and above |
| Mounting | Panel or terminal-box mount |
| Lifecycle Status | In production |
| Availability | IN STOCK, Same day shipping Worldwide available |
| Condition | Brand New, 1 Year International Warranty |
| Warranty | 1 Year International Warranty |
What the GRT8-TH1 150A is. A Analogue Automatic Voltage Regulator, high current built by GRAMEYER for brushless excitation systems. On paper the specification is a list; in service it is a set of limits. The current the board will hold indefinitely is 150 A continuous; the field resistance window it will drive without exceeding its output voltage is 6-50 ohm; the tightest voltage band it can maintain is 0.5 per cent; and the ambient range in which all of that remains true is -20 to +60 degC.
Excitation architecture. Self-excited, shunt fed. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. Take a photograph of the terminal block before removing anything. Wiring drawings for older machines are frequently wrong, and the photograph is the only reliable record.
Sensing. Single-phase sensing, 160-300 Vac or 320-600 Vac. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. The measurement that settles most arguments is the field current at full load, taken with a clamp meter, compared against the rating on the board.
Power stage and field drive. Power input 170-300 Vac single-phase or two-phase, 50 / 60 Hz, output 76.5-126 Vdc. Field current rating 150 A continuous, forcing capability 210 A for 10 s, field resistance window 6-50 ohm. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Load sharing between parallel sets is set up with an instrument, not by ear. A droop adjustment made by listening to the sets will be wrong at every load other than the one it was set at.
Accuracy and response. 0.5 per cent steady-state accuracy, Adjustable from 8 to 500 ms, thermal drift Low thermal drift. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.
Frequency behaviour. Rated for 50 / 60 Hz, with Adjustable under-frequency protection. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. Where a spare is being held, hold the drawing with it. A board without its wiring diagram costs a shift of production time to install.
Paralleling. Reactive droop for parallel operation. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. Counterfeit regulators are a real problem on the widely copied boards. Buy from a source that will state where the board was made.
Protection built into the regulator. Under-frequency, over-excitation. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. The measurement that settles most arguments is the field current at full load, taken with a clamp meter, compared against the rating on the board.
What it fits. Large frame alternators, 1000 kVA and above. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. The cheapest diagnostic tool in excitation work is a DC ammeter in the field circuit. It turns a vague symptom into a number within seconds.
Field notes on this model. The GRT8-TH1 is Grameyer's high-current range, built for alternators whose exciter field takes tens of amps. The suffix is the continuous field current, so the board has to match the alternator frame. Putting a 10 A board on a machine that needs 130 A will not simply under-perform, it will fail. These boards carry a substantial heatsink and are physically much larger than a TH4.
The retrofit case. Most GRT8-TH1 150A sales are retrofits, not new build. The machine is ten to twenty years old, the original board has failed, and the drawing is gone. In that situation the useful evidence is the exciter field resistance measured with a meter, the residual voltage measured at the AVR terminals with the machine turning at rated speed and no load, and the nameplate kVA. Those three readings will identify a compatible board even when the original part number cannot be found anywhere.
The terminal box is a hostile place. Engine vibration, radiant heat from the exhaust and conductive dust all arrive at the same panel. Mount the GRT8-TH1 150A on the resilient side of the box if there is a choice, keep it off the hottest wall, and make sure the lid actually closes over the wiring rather than pinching it. A regulator that is mechanically stressed will eventually crack a solder joint, and the resulting fault looks exactly like a failed semiconductor.
Load step test. Apply and remove at least half rated load and watch the recovery. A healthy regulator pulls the voltage back inside one per cent within a few cycles. If the recovery is slow but the final voltage is correct, the problem is response, not accuracy, and on an analogue board that usually means the field circuit is seeing more resistance than it was set up for.
The forcing margin. A regulator that can only just hold rated voltage at rated load has no forcing margin left, and the machine will dip on every load step. The GRT8-TH1 150A is specified with a minimum field resistance of 6-50 ohm; staying comfortably above that minimum, rather than exactly at it, is what leaves the forcing margin that makes a set feel solid rather than merely adequate.
Voltage drifts with ambient temperature. If the voltage is correct cold and low hot, the thermal drift of the regulator and the temperature coefficient of the field are adding up in the same direction. The GRT8-TH1 150A is specified at 0.5 per cent static; a drift of a couple of per cent over a fifty degree swing is normal for an analogue board and is not a fault.
New, old stock or refurbished. Discontinued regulators are available as new old stock, which is genuine and works, and as refurbished, which is a gamble on how the board was stored. Ask which one is being quoted. A board that has spent ten years in a damp warehouse has aged electrolytics even though it has never been installed.
Where this regulator does not belong. A GRT8-TH1 150A is a voltage regulator, not a protection relay and not a governor interface. If the site needs loss-of-mains detection, reverse power protection or synchronising, those functions live in the controller, not here. Expecting the AVR to carry them is how installations end up with a set that holds voltage beautifully and still trips the site on a mains failure.
Field cable sizing. The field circuit carries DC at low voltage and high current, so volt drop matters more than ampacity. Size the cable so that the drop at 150 A continuous stays under about one volt, and torque the terminals to the manufacturer figure. A field circuit that loses half a volt in the cable is a regulator that cannot reach full forcing when the load steps.
Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China
Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com
Jinjia Power, Quality Assured