← Back to products

Specifications

SKUKCR360
BrandKATO
Model NumberKCR360
Regulator TypeAnalogue Automatic Voltage Regulator
Excitation SystemSelf-excited or PMG depending on variant
Sensing InputSingle-phase or three-phase sensing with voltage taps
Power InputFrom the main stator, 50 / 60 Hz
Output Voltage63-125 Vdc class
Continuous Field Current4-10 A class
Forcing CurrentShort-term forcing current available for load steps
Field Resistance (Min)Matched to the exciter field
Regulation Accuracy+/-1.0 per cent
Response TimeStandard analogue response
Frequency Range50 / 60 Hz
Under-Frequency ProtectionVolts-per-hertz roll-off
Voltage AdjustmentInternal trim potentiometer
Paralleling / DroopReactive droop via CT
Build-Up VoltageBuilds up from residual voltage
Thermal DriftLow thermal drift
Operating Temperature-40 to +60 degC
Storage Temperature-40 to +85 degC
Protection FeaturesOver-excitation shutdown, loss of sensing
Compatible AlternatorsKato Engineering alternators
MountingPanel or terminal-box mount
Lifecycle StatusIn production
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 1 Year International Warranty
Warranty1 Year International Warranty

Product Overview

KATO KCR360. This is a Analogue Automatic Voltage Regulator from the KATO range, supplied as a direct replacement for the same model number in the field. The figures that matter are printed in the table above and repeated here so the page can be read on its own: field current rating 4-10 A class, field resistance window Matched to the exciter field, accuracy +/-1.0 per cent, working range -40 to +60 degC. Everything else on this page exists to explain how those four numbers decide whether the unit fits a particular alternator.

Excitation architecture. Self-excited or PMG depending on variant. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. The most common cause of intermittent excitation loss is a crimp terminal that was never properly made. Wiggle the harness with the machine running before replacing anything.

Sensing. Single-phase or three-phase sensing with voltage taps. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Vibration kills more regulators than heat does. If a board has failed twice in the same machine, look at the mounting before looking at the supplier.

Power stage and field drive. Power input From the main stator, 50 / 60 Hz, output 63-125 Vdc class. Field current rating 4-10 A class, forcing capability Short-term forcing current available for load steps, field resistance window Matched to the exciter field. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Counterfeit regulators are a real problem on the widely copied boards. Buy from a source that will state where the board was made.

Accuracy and response. +/-1.0 per cent steady-state accuracy, Standard analogue response, thermal drift Low thermal drift. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Any AVR that has been in service for more than ten years is running on borrowed time, and the failure always happens at the least convenient moment.

Frequency behaviour. Rated for 50 / 60 Hz, with Volts-per-hertz roll-off. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. A regulator rated for a minimum field resistance of a few ohms will not drive a high resistance field to full current, however good its specification looks on paper.

Paralleling. Reactive droop via CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. A regulator rated for a minimum field resistance of a few ohms will not drive a high resistance field to full current, however good its specification looks on paper.

Protection built into the regulator. Over-excitation shutdown, loss of sensing. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. A voltage that is correct at no load and low at full load is almost never an accuracy problem. It is a current limit, a resistance problem or a cable problem.

What it fits. Kato Engineering alternators. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. The most common cause of intermittent excitation loss is a crimp terminal that was never properly made. Wiggle the harness with the machine running before replacing anything.

Field notes on this model. Kato regulators are built for the alternator they are shipped with, so the model number is tied to the machine frame. On a replacement order the alternator nameplate data, meaning kVA, voltage and field resistance, is what determines the correct board, not the regulator part number alone.

What the customer is actually buying. When a regulator is quoted as a replacement, the buyer is not purchasing a circuit board. They are purchasing the certainty that the set will hold voltage on the next load step. On the KCR360 that certainty comes from the combination of 4-10 A class continuous field current and the Standard analogue response response, and it disappears the moment the field resistance drifts outside the window the board was set up for.

The terminal box is a hostile place. Engine vibration, radiant heat from the exhaust and conductive dust all arrive at the same panel. Mount the KCR360 on the resilient side of the box if there is a choice, keep it off the hottest wall, and make sure the lid actually closes over the wiring rather than pinching it. A regulator that is mechanically stressed will eventually crack a solder joint, and the resulting fault looks exactly like a failed semiconductor.

What to record. Write down the sensing tap used, the field resistance cold, the field current at no load and at full load, and the voltage trim position. Those four numbers turn the next service visit from an investigation into a comparison.

Measure, do not assume. Nameplate field resistance figures are nominal at 20 degC and are frequently wrong after a rewind. Take the measurement with a four-wire meter if one is available, because a two-wire reading on a low resistance winding includes the lead resistance and can be off by twenty per cent.

Intermittent loss of excitation. Intermittent faults are almost always mechanical: a crimp that was never properly made, a terminal screw that was tightened onto insulation, or a board that is flexing. Wiggle-test the harness with the machine running at no load and watch the field current meter.

Lifecycle status. If the board being replaced is discontinued, price the current replacement at the same time as the old-stock option. On a machine that is going to run for another ten years the current production board is almost always the cheaper decision even when the old stock is available.

The retrofit case. Most KCR360 sales are retrofits, not new build. The machine is ten to twenty years old, the original board has failed, and the drawing is gone. In that situation the useful evidence is the exciter field resistance measured with a meter, the residual voltage measured at the AVR terminals with the machine turning at rated speed and no load, and the nameplate kVA. Those three readings will identify a compatible board even when the original part number cannot be found anywhere.

The terminal box is a hostile place. Engine vibration, radiant heat from the exhaust and conductive dust all arrive at the same panel. Mount the KCR360 on the resilient side of the box if there is a choice, keep it off the hottest wall, and make sure the lid actually closes over the wiring rather than pinching it. A regulator that is mechanically stressed will eventually crack a solder joint, and the resulting fault looks exactly like a failed semiconductor.

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com