Home > VOLTAGE REGULATORS > DECS100-B11 Basler AVR โ€“ Automatic Voltage Regulator
BASLER DECS100-B11 Digital AVR | Voltage Regulator | Jinjia Power

BASLER DECS100-B11 Digital AVR - Digital Automatic Voltage Regulator for BASLER Alternators | OEM Replacement

DECS100-B11

Status: | Brand New, 1 Year International Warranty

* Contact us for pricing and full specifications

๐Ÿ“ž Get a Quote๏ผš86-13553838770
โ† Back to products

Specifications

SKUDECS100-B11
BrandBASLER
Model NumberDECS100-B11
Regulator TypeDigital Automatic Voltage Regulator
Excitation SystemSelf-excited, shunt or auxiliary-winding fed
Sensing InputSingle-phase sensing with jumper-selectable voltage range
Power InputSingle-phase, 50 / 60 Hz
Output Voltage63 Vdc class
Continuous Field Current4 Adc continuous class
Forcing CurrentShort-term forcing current available for load steps
Field Resistance (Min)15 ohm minimum
Regulation Accuracy+/-1.0 per cent
Response TimeDigital, fixed stability curve
Frequency Range50 / 60 Hz, jumper selected
Under-Frequency ProtectionVolts-per-hertz roll-off
Voltage AdjustmentInternal trim potentiometer
Paralleling / DroopReactive droop via optional CT
Build-Up VoltageBuilds up from residual voltage
Thermal DriftLow thermal drift
Operating Temperature-40 to +60 degC
Storage Temperature-40 to +85 degC
Protection FeaturesOver-excitation shutdown, loss of sensing
Compatible AlternatorsSmall and mid-size alternators, 20-500 kVA
MountingPanel or terminal-box mount
Lifecycle StatusIn production
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 1 Year International Warranty
Warranty1 Year International Warranty

Product Overview

Position in the range. The DECS100-B11 sits in the BASLER regulator family carrying the designation Digital Automatic Voltage Regulator. Its place is defined by the field current it can hold, 4 Adc continuous class, against the field resistance it can drive, 15 ohm, at +/-1.0 per cent accuracy over -40 to +60 degC. Where a machine falls outside either of the first two figures, a different member of the same family is the correct answer rather than a workaround.

Excitation architecture. Self-excited, shunt or auxiliary-winding fed. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. Never flash a field through the regulator. Disconnect the board, flash the field directly, then reconnect. Flashing through the AVR is how a working board becomes a failed board.

Sensing. Single-phase sensing with jumper-selectable voltage range. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Terminal boxes are hot, dirty and vibrating. Anything mounted inside one should be judged on how it behaves in year eight, not on how it reads on the bench.

Power stage and field drive. Power input Single-phase, 50 / 60 Hz, output 63 Vdc class. Field current rating 4 Adc continuous class, forcing capability Short-term forcing current available for load steps, field resistance window 15 ohm. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Conformal coating is the difference between a board that survives a coastal site and one that corrodes quietly in eighteen months.

Accuracy and response. +/-1.0 per cent steady-state accuracy, Digital, fixed stability curve, thermal drift Low thermal drift. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. If the machine will not hold voltage at all, disconnect the field and measure the sensing voltage first. That one reading separates a sensing fault from a field fault.

Frequency behaviour. Rated for 50 / 60 Hz, jumper selected, with Volts-per-hertz roll-off. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. Load sharing between parallel sets is set up with an instrument, not by ear. A droop adjustment made by listening to the sets will be wrong at every load other than the one it was set at.

Paralleling. Reactive droop via optional CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. The trim potentiometer is not a calibration device. If rated voltage is not reachable near the middle of its range, the sensing tap is wrong.

Protection built into the regulator. Over-excitation shutdown, loss of sensing. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. If two identical sets behave differently on the same load, swap the regulators before swapping anything else. The result tells you which side of the machine the fault is on.

What it fits. Small and mid-size alternators, 20-500 kVA. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. The trim potentiometer is not a calibration device. If rated voltage is not reachable near the middle of its range, the sensing tap is wrong.

Field notes on this model. The DECS-100 is the entry point of the Basler digital line: a sealed, potted digital regulator for small and mid-size alternators where an analogue AVC63 would historically have been used. The A01 / A05 / A11 / A15 and B01 / B05 / B11 / B15 suffixes denote the sensing and output configuration, so the suffix has to match the alternator before the unit is ordered.

Reading the application backwards. Most regulator problems arrive described as engine trouble. A set that hunts on load, or whose voltage sags for two seconds after a contactor closes, is usually reporting a field current limit rather than a fuel problem. On a DECS100-B11 the first thing to check is whether the 4 Adc continuous class figure is being reached on a cold morning, because field resistance rises with temperature in the opposite direction to copper and a board that is marginal at 20 degC can be comfortable at 50 degC or the other way round depending on the winding.

Fusing. Fit the fuse the manual specifies and nothing larger. A bigger fuse does not protect the regulator better, it protects it later. On a DECS100-B11 the fuse is there to clear a field short before the thyristor is destroyed, and a 20 A fuse in place of an 8 A one turns a cheap board replacement into a rewind.

Bench test before installation. Where a spare board is available, test it on the bench with a variable AC supply into the power input and a resistor bank as the field load. A board that cannot hold a steady output into a resistor will not hold it into an exciter either, and finding that out on the bench costs nothing.

Temperature drift of the field. Copper rises about 0.4 per cent in resistance per degC, so a field that measures 12 ohm cold will measure around 15 ohm at a 70 degC winding temperature. A regulator set up on a cold machine and never re-checked will therefore be running at a different operating point every time the season changes, and the symptom is a voltage that is correct in winter and low in summer.

Intermittent loss of excitation. Intermittent faults are almost always mechanical: a crimp that was never properly made, a terminal screw that was tightened onto insulation, or a board that is flexing. Wiggle-test the harness with the machine running at no load and watch the field current meter.

Part numbers are not interchangeable across suffixes. On this family the suffix carries the field current class, the sensing arrangement or the frequency band, and two boards that look identical in a photograph can be a hundred per cent different in rating. Quote the full model number including the suffix, and where the suffix is unclear send a photograph of the original board with the terminal markings visible.

What the customer is actually buying. When a regulator is quoted as a replacement, the buyer is not purchasing a circuit board. They are purchasing the certainty that the set will hold voltage on the next load step. On the DECS100-B11 that certainty comes from the combination of 4 Adc continuous class continuous field current and the Digital, fixed stability curve response, and it disappears the moment the field resistance drifts outside the window the board was set up for.

The terminal box is a hostile place. Engine vibration, radiant heat from the exhaust and conductive dust all arrive at the same panel. Mount the DECS100-B11 on the resilient side of the box if there is a choice, keep it off the hottest wall, and make sure the lid actually closes over the wiring rather than pinching it. A regulator that is mechanically stressed will eventually crack a solder joint, and the resulting fault looks exactly like a failed semiconductor.