86-0769-89610677 / 86-13553838770 | info@jinjiadongli.com
Home > VOLTAGE REGULATORS > KR7FFMX - Basler
BASLER KR7FFMX Analogue AVR | Voltage Regulator | Jinjia Power

BASLER KR7FFMX Analogue AVR - Analogue Automatic Voltage Regulator for BASLER Alternators | OEM Replacement

KR7FFMX

Status: IN STOCK, Same day shipping Worldwide available | Brand New, 1 Year International Warranty

* Contact us for pricing and full specifications

📞 Get a Quote:86-13553838770
← Back to products

Specifications

SKUKR7FFMX
BrandBASLER
Model NumberKR7FFMX
Regulator TypeAnalogue Automatic Voltage Regulator
Excitation SystemSelf-excited
Sensing InputSingle-phase, 120 / 240 V class
Power InputSingle-phase, 50 / 60 Hz
Output Voltage63 Vdc class
Continuous Field Current4 Adc continuous
Forcing CurrentShort-term forcing current available for load steps
Field Resistance (Min)15 ohm minimum
Regulation Accuracy+/-1.0 per cent
Response TimeAbout 20 ms
Frequency Range50 / 60 Hz
Under-Frequency ProtectionNot published for this model - ask us for the nameplate data
Voltage AdjustmentInternal trim potentiometer
Paralleling / DroopReactive droop via CT
Build-Up VoltageBuilds up from residual voltage
Thermal DriftLow thermal drift
Operating Temperature-40 to +60 degC
Storage Temperature-40 to +85 degC
Protection FeaturesOver-excitation shutdown
Compatible AlternatorsLegacy Basler-equipped alternators
MountingPanel or terminal-box mount
Lifecycle StatusObsolete, superseded by the AVC63 series
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 1 Year International Warranty
Warranty1 Year International Warranty

Product Overview

Position in the range. The KR7FFMX sits in the BASLER regulator family carrying the designation Analogue Automatic Voltage Regulator. Its place is defined by the field current it can hold, 4 Adc continuous, against the field resistance it can drive, 15 ohm, at +/-1.0 per cent accuracy over -40 to +60 degC. Where a machine falls outside either of the first two figures, a different member of the same family is the correct answer rather than a workaround.

Excitation architecture. Self-excited. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. The cheapest diagnostic tool in excitation work is a DC ammeter in the field circuit. It turns a vague symptom into a number within seconds.

Sensing. Single-phase, 120 / 240 V class. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Vibration kills more regulators than heat does. If a board has failed twice in the same machine, look at the mounting before looking at the supplier.

Power stage and field drive. Power input Single-phase, 50 / 60 Hz, output 63 Vdc class. Field current rating 4 Adc continuous, forcing capability Short-term forcing current available for load steps, field resistance window 15 ohm. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. On a machine that has been standing for months, check residual voltage before condemning anything: a winding that has lost its remanence will not build up on any regulator.

Accuracy and response. +/-1.0 per cent steady-state accuracy, About 20 ms, thermal drift Low thermal drift. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Where a spare is being held, hold the drawing with it. A board without its wiring diagram costs a shift of production time to install.

Frequency behaviour. Rated for 50 / 60 Hz, with Not published for this model - ask us for the nameplate data. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. Never flash a field through the regulator. Disconnect the board, flash the field directly, then reconnect. Flashing through the AVR is how a working board becomes a failed board.

Paralleling. Reactive droop via CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. If two identical sets behave differently on the same load, swap the regulators before swapping anything else. The result tells you which side of the machine the fault is on.

Protection built into the regulator. Over-excitation shutdown. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. Load sharing between parallel sets is set up with an instrument, not by ear. A droop adjustment made by listening to the sets will be wrong at every load other than the one it was set at.

What it fits. Legacy Basler-equipped alternators. Lifecycle status: Obsolete, superseded by the AVC63 series. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. If two identical sets behave differently on the same load, swap the regulators before swapping anything else. The result tells you which side of the machine the fault is on.

Field notes on this model. The KR7FFMX is an obsolete Basler regulator that still turns up on older generator sets. It is worth replacing rather than repairing: the modern AVC63-4 fits the same terminal box and gives the same electrical performance in a sealed housing.

Parallel operation is a different animal. A single set on an island load only has to hold voltage. Two sets in parallel also have to agree about reactive load, and that agreement is made or broken by the droop circuit, not by the voltage accuracy. If a site is going to parallel, the regulator choice has to be made with the droop method in mind from the beginning, because retrofitting load sharing onto a board that was never specified for it costs more than buying the right one.

Fusing. Fit the fuse the manual specifies and nothing larger. A bigger fuse does not protect the regulator better, it protects it later. On a KR7FFMX the fuse is there to clear a field short before the thyristor is destroyed, and a 20 A fuse in place of an 8 A one turns a cheap board replacement into a rewind.

Bench test before installation. Where a spare board is available, test it on the bench with a variable AC supply into the power input and a resistor bank as the field load. A board that cannot hold a steady output into a resistor will not hold it into an exciter either, and finding that out on the bench costs nothing.

Series resistance is not a fix. Adding a resistor in series with the field to bring it inside a regulator window costs forcing current exactly when the machine needs it most. If the field resistance is outside the window, change the board, not the circuit.

Voltage low under load only. This is the classic field current limit symptom. Measure the field current at full load and compare it with the 4 Adc continuous figure for the KR7FFMX. If the board is at its limit, either the board is too small for the alternator or the field resistance has risen. A rewind, a corroded terminal or a long cable run will all produce the same reading.

Delivery and packing. Regulators are static-sensitive assemblies and should arrive in a sealed bag with foam, not loose in a box with a heatsink. Inspect on arrival and photograph the packaging before opening if there is any sign of crush damage.

What the customer is actually buying. When a regulator is quoted as a replacement, the buyer is not purchasing a circuit board. They are purchasing the certainty that the set will hold voltage on the next load step. On the KR7FFMX that certainty comes from the combination of 4 Adc continuous continuous field current and the About 20 ms response, and it disappears the moment the field resistance drifts outside the window the board was set up for.

Earthing and shielding. The regulator reference is the machine frame. Bond the AVR mounting plate to the frame with a dedicated conductor rather than relying on the mounting screws, and earth the sensing cable shield at one end only. When a set shows a voltage that wanders slowly with no load change, the cause is usually a circulating current in the shield rather than a failing board.

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com

Jinjia Power, Quality Assured