Status: IN STOCK, Same day shipping Worldwide available |
* Contact us for pricing and full specifications
| SKU | VR485L |
| Brand | BASLER |
| Model Number | VR485L |
| Regulator Type | Analogue Automatic Voltage Regulator |
| Excitation System | Self-excited |
| Sensing Input | Single-phase, 380-480 V class |
| Power Input | Single-phase, 50 / 60 Hz |
| Output Voltage | 63 Vdc class |
| Continuous Field Current | 4 Adc continuous |
| Forcing Current | Short-term forcing current available for load steps |
| Field Resistance (Min) | 15 ohm minimum |
| Regulation Accuracy | +/-1.0 per cent |
| Response Time | About 20 ms |
| Frequency Range | 50 / 60 Hz |
| Under-Frequency Protection | Volts-per-hertz roll-off |
| Voltage Adjustment | Internal trim potentiometer |
| Paralleling / Droop | Reactive droop via CT |
| Build-Up Voltage | Builds up from residual voltage |
| Thermal Drift | Low thermal drift |
| Operating Temperature | -40 to +60 degC |
| Storage Temperature | -40 to +85 degC |
| Protection Features | Over-excitation shutdown |
| Compatible Alternators | 480 V class alternators |
| Mounting | Panel or terminal-box mount |
| Lifecycle Status | In production |
| Availability | IN STOCK, Same day shipping Worldwide available |
| Condition | Brand New, 1 Year International Warranty |
| Warranty | 1 Year International Warranty |
BASLER VR485L. This is a Analogue Automatic Voltage Regulator from the BASLER range, supplied as a direct replacement for the same model number in the field. The figures that matter are printed in the table above and repeated here so the page can be read on its own: field current rating 4 Adc continuous, field resistance window 15 ohm, accuracy +/-1.0 per cent, working range -40 to +60 degC. Everything else on this page exists to explain how those four numbers decide whether the unit fits a particular alternator.
Excitation architecture. Self-excited. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.
Sensing. Single-phase, 380-480 V class. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Where a board has been superseded, the replacement usually fits the same footprint but not the same terminal numbering. Read the drawing, do not read the old wiring.
Power stage and field drive. Power input Single-phase, 50 / 60 Hz, output 63 Vdc class. Field current rating 4 Adc continuous, forcing capability Short-term forcing current available for load steps, field resistance window 15 ohm. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Where a spare is being held, hold the drawing with it. A board without its wiring diagram costs a shift of production time to install.
Accuracy and response. +/-1.0 per cent steady-state accuracy, About 20 ms, thermal drift Low thermal drift. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Conformal coating is the difference between a board that survives a coastal site and one that corrodes quietly in eighteen months.
Frequency behaviour. Rated for 50 / 60 Hz, with Volts-per-hertz roll-off. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. Counterfeit regulators are a real problem on the widely copied boards. Buy from a source that will state where the board was made.
Paralleling. Reactive droop via CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. The measurement that settles most arguments is the field current at full load, taken with a clamp meter, compared against the rating on the board.
Protection built into the regulator. Over-excitation shutdown. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.
What it fits. 480 V class alternators. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. Take a photograph of the terminal block before removing anything. Wiring drawings for older machines are frequently wrong, and the photograph is the only reliable record.
Field notes on this model. The VR485 is the 480 V variant of the Basler analogue family, with the sensing transformer built for direct connection to a 480 V terminal set. The P and L suffixes denote the terminal arrangement and the enclosure style rather than a different electrical rating.
What the customer is actually buying. When a regulator is quoted as a replacement, the buyer is not purchasing a circuit board. They are purchasing the certainty that the set will hold voltage on the next load step. On the VR485L that certainty comes from the combination of 4 Adc continuous continuous field current and the About 20 ms response, and it disappears the moment the field resistance drifts outside the window the board was set up for.
Mounting orientation and cooling. Most AVR boards are convection cooled and assume the heatsink fins are vertical. Mounting a VR485L flat on its back inside a sealed box shortens its life even though the ambient temperature reads acceptable, because the local air around the thyristor is far hotter than the box average.
When the trim runs out of range. If full rotation of the voltage trim still will not bring the machine to rated voltage, the sensing tap is wrong. Moving one tap changes the reference by a factor of about two, so the correct tap is the one that puts rated voltage near the middle of the trim range rather than at either end.
Series resistance is not a fix. Adding a resistor in series with the field to bring it inside a regulator window costs forcing current exactly when the machine needs it most. If the field resistance is outside the window, change the board, not the circuit.
Symptom first, board second. A set that will not build up voltage has one of four causes: no residual magnetism, a broken sensing circuit, a failed regulator, or a field circuit open. Test them in that order, because the first two are free to check and the third is not. Flashing the field with a battery through a resistor will separate a residual problem from a regulator problem in under a minute.
Warranty and what it covers. A one year warranty on a regulator is meaningful only if it covers a field-side failure and not just a dead-on-arrival check. Ask whether a board that fails after six months in service is replaced without argument, because that is the failure mode that actually happens.
Matching the board to the duty, not to the label. Two BASLER alternators of the same kVA can need different regulators if one is specified for motor starting and the other for a resistive load. The VR485L is specified at +/-1.0 per cent regulation accuracy, which is the number that matters when the load is a mix of drives and lighting. For a purely resistive load even a looser board is invisible to the customer, and paying for accuracy that nobody measures is the most common way money is wasted on a rebuild.
Field cable sizing. The field circuit carries DC at low voltage and high current, so volt drop matters more than ampacity. Size the cable so that the drop at 4 Adc continuous stays under about one volt, and torque the terminals to the manufacturer figure. A field circuit that loses half a volt in the cable is a regulator that cannot reach full forcing when the load steps.