BASLER AEC42-7 Analogue AVR | Voltage Regulator | Jinjia Power

BASLER AEC42-7 Analogue AVR - Analogue Automatic Voltage Regulator for BASLER Alternators | OEM Replacement

AEC42-7

Status: IN STOCK, Same day shipping Worldwide available |

* Contact us for pricing and full specifications

📞 Get a Quote:86-13553838770
← Back to products

Specifications

SKUAEC42-7
BrandBASLER
Model NumberAEC42-7
Regulator TypeAnalogue Automatic Voltage Regulator
Excitation SystemSelf-excited, shunt fed
Sensing Input200-252 Vac +/-10 per cent, two-phase, 50 / 60 Hz, under 1 VA burden
Power Input220-260 Vac single-phase, 50 / 60 Hz, burden below 900 VA
Output Voltage42 Vdc nominal, 90 Vdc during forcing
Continuous Field Current7 Adc continuous at 42 Vdc
Forcing Current15 Adc for 10 s at 90 Vdc with 240 V input
Field Resistance (Min)6 ohm minimum, 105 ohm maximum
Regulation AccuracyBetter than 1 per cent from no load to full load on average sensing
Response TimeBetter than 1.5 cycles for a 5 per cent sensing voltage change
Frequency Range50 / 60 Hz
Under-Frequency ProtectionTwo times volts-per-hertz frequency compensation
Voltage AdjustmentVoltage range 180-277 Vac via internal adjustment
Paralleling / Droop10 per cent droop with a 5 Vac CT input
Build-Up VoltageAutomatic build-up from 6 Vac residual
Thermal DriftLow, internal EMI filter fitted
Operating Temperature-20 to +60 degC
Storage Temperature-40 to +85 degC
Protection FeaturesDelayed inverse-time over-excitation shutdown, no trip at 50 Vdc and instantaneous at 100 Vdc, with a disable link for paralleling
Compatible AlternatorsStamford and Caterpillar-style alternators with 6-105 ohm fields
MountingPanel or terminal-box mount
Lifecycle StatusIn production
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 1 Year International Warranty
Warranty1 Year International Warranty

Product Overview

BASLER AEC42-7. This is a Analogue Automatic Voltage Regulator from the BASLER range, supplied as a direct replacement for the same model number in the field. The figures that matter are printed in the table above and repeated here so the page can be read on its own: field current rating 7 Adc continuous at 42 Vdc, field resistance window 6 ohm, accuracy Better than 1 per cent from no load to, working range -20 to +60 degC. Everything else on this page exists to explain how those four numbers decide whether the unit fits a particular alternator.

Excitation architecture. Self-excited, shunt fed. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. The cheapest diagnostic tool in excitation work is a DC ammeter in the field circuit. It turns a vague symptom into a number within seconds.

Sensing. 200-252 Vac +/-10 per cent, two-phase, 50 / 60 Hz, under 1 VA burden. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. A voltage that is correct at no load and low at full load is almost never an accuracy problem. It is a current limit, a resistance problem or a cable problem.

Power stage and field drive. Power input 220-260 Vac single-phase, 50 / 60 Hz, burden below 900 VA, output 42 Vdc nominal, 90 Vdc during forcing. Field current rating 7 Adc continuous at 42 Vdc, forcing capability 15 Adc for 10 s at 90 Vdc with 240 V input, field resistance window 6 ohm. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. On a machine that has been standing for months, check residual voltage before condemning anything: a winding that has lost its remanence will not build up on any regulator.

Accuracy and response. Better than 1 per cent from no load to steady-state accuracy, Better than 1.5 cycles for a 5 per cent sensing voltage change, thermal drift Low, internal EMI filter fitted. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Terminal boxes are hot, dirty and vibrating. Anything mounted inside one should be judged on how it behaves in year eight, not on how it reads on the bench.

Frequency behaviour. Rated for 50 / 60 Hz, with Two times volts-per-hertz frequency compensation. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. Never flash a field through the regulator. Disconnect the board, flash the field directly, then reconnect. Flashing through the AVR is how a working board becomes a failed board.

Paralleling. 10 per cent droop with a 5 Vac CT input. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. The most common cause of intermittent excitation loss is a crimp terminal that was never properly made. Wiggle the harness with the machine running before replacing anything.

Protection built into the regulator. Delayed inverse-time over-excitation shutdown, no trip at 50 Vdc and instantaneous at 100 Vdc, with a disable link for paralleling. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. Take a photograph of the terminal block before removing anything. Wiring drawings for older machines are frequently wrong, and the photograph is the only reliable record.

What it fits. Stamford and Caterpillar-style alternators with 6-105 ohm fields. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. Static accuracy is measured on a resistive load at constant frequency. Real loads and real governors are neither, so treat the figure as a comparison between boards rather than a promise.

Field notes on this model. The AEC42-7 is a low-voltage analogue regulator: 42 Vdc nominal into a 6-105 ohm field, with a 15 A forcing burst for motor starting. The wide field resistance window is what makes it useful on older alternators whose exciter field was never designed around a modern AVR. Power draw is about 20 W typical, so it runs cool inside a closed terminal box.

Standby versus prime power. A standby set runs a few hundred hours a year and its regulator spends most of its life cold; a prime power set runs continuously and its regulator spends its life at operating temperature. The AEC42-7 is rated for -20 to +60 degC, which is fine in both cases provided the terminal box has any ventilation at all. What changes between the two duties is the capacitor ageing inside the board, not the semiconductor, so a prime power machine should have the regulator inspected on a schedule rather than on failure.

Earthing and shielding. The regulator reference is the machine frame. Bond the AVR mounting plate to the frame with a dedicated conductor rather than relying on the mounting screws, and earth the sensing cable shield at one end only. When a set shows a voltage that wanders slowly with no load change, the cause is usually a circulating current in the shield rather than a failing board.

Under-frequency check. Run the set at reduced speed and confirm the volts-per-hertz knee actually operates. This test is skipped on most commissioning sheets and it is the one that saves an engine on a real overload, because the knee is what stops the alternator from loading a lugging engine into a stall.

Temperature drift of the field. Copper rises about 0.4 per cent in resistance per degC, so a field that measures 12 ohm cold will measure around 15 ohm at a 70 degC winding temperature. A regulator set up on a cold machine and never re-checked will therefore be running at a different operating point every time the season changes, and the symptom is a voltage that is correct in winter and low in summer.

Voltage drifts with ambient temperature. If the voltage is correct cold and low hot, the thermal drift of the regulator and the temperature coefficient of the field are adding up in the same direction. The AEC42-7 is specified at Better than 1 per cent from no load to full load on average sensing; a drift of a couple of per cent over a fifty degree swing is normal for an analogue board and is not a fault.

Counterfeits. Where a board is widely copied, buy from a source that will state the country of manufacture and stand behind it. A counterfeit regulator usually works for a month and then fails on the first cold morning, and by then the machine has a reputation problem rather than a parts problem.

The retrofit case. Most AEC42-7 sales are retrofits, not new build. The machine is ten to twenty years old, the original board has failed, and the drawing is gone. In that situation the useful evidence is the exciter field resistance measured with a meter, the residual voltage measured at the AVR terminals with the machine turning at rated speed and no load, and the nameplate kVA. Those three readings will identify a compatible board even when the original part number cannot be found anywhere.

Field cable sizing. The field circuit carries DC at low voltage and high current, so volt drop matters more than ampacity. Size the cable so that the drop at 7 Adc continuous at 42 Vdc stays under about one volt, and torque the terminals to the manufacturer figure. A field circuit that loses half a volt in the cable is a regulator that cannot reach full forcing when the load steps.