86-0769-89610677 / 86-13553838770 | info@jinjiadongli.com
Home > TRANSFER SWITCHES > ZTX000M60040B-ZEC3R-ZVC20-M060 Series ZTX - GE Zenith | Automatic, 400 AMP
ZTX000M60040B-ZEC3R-ZVC20-M060 Series ZTX - GE Zenith | Automatic, 400 AMP

ZTX000M60040B-ZEC3R-ZVC20-M060 Series ZTX - GE Zenith | Automatic, 400 AMP

ZTX000M60040B-ZEC3R-ZVC20-M060

Status: IN STOCK, Same day shipping Worldwide available | Brand New, Certified Factory Original

Volume, OEM and project pricing available on request.

πŸ“ž Get a Quote:86-13553838770
← Back to products

Specifications

Catalog NumberZTX000M60040B-ZEC3R-ZVC20-M060
SeriesGE Zenith ZTX
Product TypeAutomatic Transfer Switch (ATS)
Ampere Rating400 A
Number of Poles2 Poles
Voltage Rating240V (1-phase, 3-wire)
Frequency60 Hz
EnclosureNEMA 3R (Outdoor Rain-tight)
Transition TypeOpen Transition
ControllerMX60 microprocessor control panel
Switching MechanismDouble-throw, mechanically interlocked contactor; electrically operated, mechanically held
Operating Transfer TimeLess than 500 ms
Load Interrupting TimeLess than 50 ms
Mechanical Endurance3,050 operations
Terminals1 Γ— #4 AWG – 600 kcmil per pole
Withstand Rating (UL 1008)50 kA with coordinated breaker / 200 kA with current-limiting fuse
Operating Temperature-20 to +40 Β°C without derating
CertificationUL 1008 / CSA / IEC listed to 480 Vac
Applicable StandardNEC / NFPA 70 Article 702 (optional standby)
Generator CompatibilityTwo-wire automatic-start generators
ManufacturerGE Zenith Controls (now ABB)
AvailabilityIN STOCK β€” same-day shipping, worldwide
ConditionBrand New, Certified Factory Original
Warranty1 Year

Product Overview

The GE Zenith ZTX series is a compact automatic transfer switch built on a double-throw, mechanically interlocked contactor mechanism: electrically operated and mechanically held, with no solenoid trip to wear out and no neutral position to mis-sequence. The platform covers 30 A to 1,200 A at 200-480 Vac and is listed to UL 1008, CSA and IEC. Zenith Controls was a General Electric business; the ZTX range is now manufactured by ABB and the catalog numbers are unchanged, so a ZTX ordered today is the same switch that has been installed in North American light-commercial buildings for decades. This unit is rated 400 A, 240V, 2-pole, NEMA 3R, open transition. Typical loads are a whole-building distribution panel, a rooftop packaged unit group, a small data or telecom room, a clinic or a restaurant β€” installations where the transfer switch is sized to the full service and must coordinate with the upstream overcurrent protection. The NEMA 3R enclosure is rain-tight and rated for outdoor mounting against a wall or on a pad, so the switch can sit next to an exterior generator without an additional weather shelter. Terminations and footprint. One conductor per pole from #4 AWG to 600 kcmil in the 46 in by 24 in by 14 in floor-standing enclosure, 50 kA withstand with a breaker and 200 kA with current-limiting fuses. 400 A is the top of the ZTX range in this configuration and the point where a service normally moves to a bolted-pressure switch rather than a contactor type: the feeder is pulled with a rope and a tugger, not by hand, and the terminations have to stay reachable with the line side energised. Service arrangement. Two-pole 120/240 V single-phase: two ungrounded conductors and a grounded neutral, the arrangement behind nearly every North American dwelling and behind small shops on a split-phase service. Only two poles switch, so a solid-neutral unit carries the grounded conductor straight through while a switched-neutral unit opens it β€” which is what you want when the generator is treated as a separately derived source and the neutral must be broken to keep the two grounding electrodes apart. Enclosure. The Type 3R cabinet is rain-tight, not watertight: it is built for outdoor mounting against a wall or on a pad, with a hooded or sloped top that sheds water and a gasketed door that keeps driven rain out. What it does not do is keep out dust or hose spray, and the installation still has to do its part β€” conduit entries need drip loops or sealing hubs so water running down the conduit cannot track into the enclosure, and the mounting surface has to drain. A 3R unit on a north wall in a coastal yard will outlast three indoor units in the same spot, which is why it is the default for anything not under a roof. Matching generator. At 240V with an 0.8 power factor this switch carries approximately 77 kW of load (400 A Γ— 240V Γ— 0.8 = 76.8 kW, single-phase two-wire). Size the standby generator so that its standby rating meets or exceeds that figure, and confirm the generator's two-wire automatic-start contacts are compatible with the transfer switch controller. Control. The ZTX is supplied with the MX60 microprocessor control panel: undervoltage sensing on Source 1 at 90 % pickup and 80 % dropout, voltage and frequency sensing on Source 2 at 90 % voltage and 95 % frequency pickup, and fixed time delays β€” engine start 3 s, transfer to generator 15 s, retransfer to utility 5 minutes, engine cool-down 1 minute. The panel carries LEDs for source availability and switch position, pushbuttons for test, exerciser set, timer bypass and program cancel, and a selectable 7 / 14 / 21 / 28-day generator exerciser (factory set to 28 days). All time delays are fixed and not field-adjustable β€” that is deliberate: the ZTX is aimed at installations where nobody is going to re-commission the switch after the building is handed over. Two-pole switching. Both the hot and the neutral are opened, which is the normal arrangement for 120/240 V single-phase residential and light-commercial services. Supply. Supplied as a genuine GE Zenith Controls (now ABB) ZTX unit, brand new and factory original, packed for export from our Dongguan warehouse. Ask us for the outline drawing, wiring diagram and MX60 control manual for this exact catalog number.

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com

Jinjia Power, Quality Assured

Frequently Asked Questions

What is the ZTX000M60040B-ZEC3R-ZVC20-M060 transfer switch rated for?

The ZTX000M60040B-ZEC3R-ZVC20-M060 is rated 400 A at 240V (1-phase, 3-wire), 2-pole. It is a Automatic Transfer Switch (ATS) built on GE Zenith ZTX.

What type of transfer switch is the ZTX000M60040B-ZEC3R-ZVC20-M060?

ZTX000M60040B-ZEC3R-ZVC20-M060 is a Automatic Transfer Switch (ATS) in the GE Zenith ZTX family with Open Transition.

Which generators can the ZTX000M60040B-ZEC3R-ZVC20-M060 be used with?

The ZTX000M60040B-ZEC3R-ZVC20-M060 is specified for Two-wire automatic-start generators. Match the switch ampere rating to the generator output current and confirm the voltage and pole configuration before ordering.

What controller does the ZTX000M60040B-ZEC3R-ZVC20-M060 use?

The ZTX000M60040B-ZEC3R-ZVC20-M060 uses MX60 microprocessor control panel. The controller supervises the normal and emergency sources and drives the transfer sequence.

What enclosure does the ZTX000M60040B-ZEC3R-ZVC20-M060 come in?

The ZTX000M60040B-ZEC3R-ZVC20-M060 is supplied in NEMA 3R (Outdoor Rain-tight). Confirm the enclosure rating against your installation environment, indoor or outdoor, before ordering.

What certifications and standards does the ZTX000M60040B-ZEC3R-ZVC20-M060 meet?

ZTX000M60040B-ZEC3R-ZVC20-M060 is certified to UL 1008 / CSA / IEC listed to 480 Vac. It is designed and tested to NEC / NFPA 70 Article 702 (optional standby). Request the current certificate for your project file before submission.

How fast does the ZTX000M60040B-ZEC3R-ZVC20-M060 transfer between sources?

The ZTX000M60040B-ZEC3R-ZVC20-M060 completes the transfer in Less than 500 ms. Confirm the acceptable interruption time for your loads, since motor and UPS loads have different tolerances.

How many poles does the ZTX000M60040B-ZEC3R-ZVC20-M060 have?

The ZTX000M60040B-ZEC3R-ZVC20-M060 is a 2-pole device. Pole count must match your distribution: single phase two wire, three phase three wire, or three phase four wire with neutral.

What frequency does the ZTX000M60040B-ZEC3R-ZVC20-M060 operate at?

The ZTX000M60040B-ZEC3R-ZVC20-M060 is rated for 60 Hz. Confirm the generator and the utility supply are on the same frequency before installation.

How durable is the ZTX000M60040B-ZEC3R-ZVC20-M060 under repeated transfers?

The ZTX000M60040B-ZEC3R-ZVC20-M060 is rated for 3,050 operations mechanical operations, with a 50 kA with coordinated breaker / 200 kA with current-limiting fuse withstand rating.

What terminals does the ZTX000M60040B-ZEC3R-ZVC20-M060 provide for cable connection?

The ZTX000M60040B-ZEC3R-ZVC20-M060 provides 1 Γ— #4 AWG – 600 kcmil per pole. Size incoming and outgoing cables to the terminal capacity and to the ampere rating of the switch.

Who makes the ZTX000M60040B-ZEC3R-ZVC20-M060 and what is the supply status?

ZTX000M60040B-ZEC3R-ZVC20-M060 is manufactured by GE Zenith Controls (now ABB). Current availability: IN STOCK β€” same-day shipping, worldwide. Condition: Brand New, Certified Factory Original. Warranty: 1 Year.