Product Overview
The GE Zenith ZTX series is a compact automatic transfer switch built on a double-throw, mechanically interlocked contactor mechanism: electrically operated and mechanically held, with no solenoid trip to wear out and no neutral position to mis-sequence. The platform covers 30 A to 1,200 A at 200-480 Vac and is listed to UL 1008, CSA and IEC. Zenith Controls was a General Electric business; the ZTX range is now manufactured by ABB and the catalog numbers are unchanged, so a ZTX ordered today is the same switch that has been installed in North American light-commercial buildings for decades. This unit is rated 300 A, 208V, 3-pole, NEMA 1, open transition. Typical loads are a whole-building distribution panel, a rooftop packaged unit group, a small data or telecom room, a clinic or a restaurant β installations where the transfer switch is sized to the full service and must coordinate with the upstream overcurrent protection. The NEMA 1 enclosure is intended for indoor installation in a dry, protected space such as a mechanical room or an electrical closet. Terminations and footprint. One conductor per pole from #4 AWG to 600 kcmil, in a 46 in high by 24 in wide by 14 in deep floor-standing cabinet. The withstand rating steps up to 50 kA with a breaker and 200 kA with current-limiting fuses, and mechanical life drops to 3,050 operations β the contacts are heavier and the mechanism does more work per operation. At this size the switch sits on a housekeeping pad beside the service equipment. Service arrangement. This is a 208Y/120 V three-phase four-wire switch β the service found in office buildings, retail strips, clinics and small data rooms, where one panelboard feeds 208 V three-phase loads and 120 V receptacle circuits off a solid neutral. The neutral is not switched, because it is bonded at the service and opening it would defeat ground-fault sensing. Enclosure. The Type 1 cabinet is for indoor use in a dry, protected space β a mechanical room, an electrical closet, a plant room β where the only thing it has to keep out is incidental dust and the occasional touch. It is not rain-tight and not watertight: mounting one on an exterior wall, even under a soffit, invites water in through the door seam and the conduit knockouts, and the first sign is usually a rusted mechanism rather than a tripped breaker. If the switch has to live outdoors, the 3R version of the same rating is the one to order. Matching generator. At 208V with an 0.8 power factor this switch carries approximately 86 kW of load (300 A Γ 208V Γ β3 Γ 0.8 = 86 kW, three-phase). Size the standby generator so that its standby rating meets or exceeds that figure, and confirm the generator's two-wire automatic-start contacts are compatible with the transfer switch controller. Control. The ZTX is supplied with the MX60 microprocessor control panel: undervoltage sensing on Source 1 at 90 % pickup and 80 % dropout, voltage and frequency sensing on Source 2 at 90 % voltage and 95 % frequency pickup, and fixed time delays β engine start 3 s, transfer to generator 15 s, retransfer to utility 5 minutes, engine cool-down 1 minute. The panel carries LEDs for source availability and switch position, pushbuttons for test, exerciser set, timer bypass and program cancel, and a selectable 7 / 14 / 21 / 28-day generator exerciser (factory set to 28 days). All time delays are fixed and not field-adjustable β that is deliberate: the ZTX is aimed at installations where nobody is going to re-commission the switch after the building is handed over. Three-pole switching. The three phase conductors are switched with the neutral solid, the standard arrangement for 208Y/120 V and 480Y/277 V three-phase services where the neutral is bonded at the service and must not be opened. Supply. Supplied as a genuine GE Zenith Controls (now ABB) ZTX unit, brand new and factory original, packed for export from our Dongguan warehouse. Ask us for the outline drawing, wiring diagram and MX60 control manual for this exact catalog number.