86-0769-89610677 / 86-13553838770 | info@jinjiadongli.com
Home > TRANSFER SWITCHES > 3ATSB31600FG0C Series 300 - ASCO | Automatic, 1600 AMP
3ATSB31600FG0C Series 300 - ASCO | Automatic, 1600 AMP
3ATSB31600FG0C ASCO 1600 A3ATSB31600FG0C ASCO 1600 A3ATSB31600FG0C ASCO 1600 A3ATSB31600FG0C ASCO 1600 A3ATSB31600FG0C ASCO 1600 A

3ATSB31600FG0C Series 300 - ASCO | Automatic, 1600 AMP

3ATSB31600FG0C

Status: IN STOCK, Same day shipping Worldwide available | Brand New, Certified Factory Original

Volume, OEM and project pricing available on request.

πŸ“ž Get a Quote:86-13553838770
← Back to products

Specifications

Catalog Number3ATSB31600FG0C
SeriesASCO Series 300
Product TypeAutomatic Transfer Switch (ATS)
Ampere Rating1600 A
Number of Poles3 Poles
Voltage Rating240V
Neutral ConfigurationSwitched Neutral
Frequency50 / 60 Hz
EnclosureNEMA 1 (Indoor)
Transition TypeOpen Transition
ControllerGroup G
CertificationUL 1008 Listed
Applicable StandardNEC / NFPA 70 Articles 700, 701 and 702
Generator CompatibilityTwo-wire automatic-start generators
Load Disconnect Contact5 A resistive at 30 VDC max / 100 mA at 5 VDC min
Communication (opt. 11BE)RS-485, 9,600–11,5200 bps, address 1–247
ManufacturerASCO Power Technologies (Schneider Electric)
AvailabilityIN STOCK β€” same-day shipping, worldwide
ConditionBrand New, Certified Factory Original
Warranty1 Year

Product Overview

The ASCO Series 300 is a UL 1008-listed automatic transfer switch built for commercial, institutional and light-industrial standby power. It monitors both the utility and the generator source and transfers the load automatically when the normal source falls outside acceptable limits, then returns it once the utility is restored and stable. This unit is rated 1600 A, 240V, 3-pole, NEMA 1, open transition. Typical loads are a main-tie-main arrangement, a large central utility plant, a data hall or an industrial process bus β€” installations where the transfer switch is engineered to order, coordinated with the service entrance equipment and frequently supplied with bypass isolation or delayed transition. The NEMA 1 enclosure is intended for indoor installation in a dry, protected space such as a mechanical room or an electrical closet. Terminations and footprint. Six conductors per pole from 1/0 AWG to 600 kcmil, in a 38 in by 87 in by 23 in engineered-to-order assembly of roughly 1,160 lb. At this size the switch is built to an outline drawing rather than to a catalogue dimension: busbar connections replace cable lugs where the design calls for it, mechanical lifting provisions are part of the enclosure, and the pad is poured to that drawing. Six conductors per phase means a phase-grouped pull with supports every few feet. Service arrangement. Three-pole on a 240 V delta system: three ungrounded conductors with no usable neutral for line-to-neutral loads, still common in older industrial plants, farms, grain elevators and water districts where the service was built around motor loads. A delta service may be corner-grounded, so confirm the bonding jumper arrangement before dropping this switch into an existing service β€” it is the one voltage in this range where the neutral question is not academic. Neutral configuration. The neutral is switched β€” it opens and closes with the phase poles as one more pole. You need this when the generator is wired as a separately derived source with its own grounding electrode and its own main bonding jumper: leaving the neutral solid would tie the two grounding systems together through the neutral, put objectionable current on the grounding conductor and leave the generator frame at a potential above earth during a fault. It costs one more pole and one more set of contacts to maintain, but on a separately derived system it is not optional, and an inspector will look for it. Enclosure. The Type 1 cabinet is for indoor use in a dry, protected space β€” a mechanical room, an electrical closet, a plant room β€” where the only thing it has to keep out is incidental dust and the occasional touch. It is not rain-tight and not watertight: mounting one on an exterior wall, even under a soffit, invites water in through the door seam and the conduit knockouts, and the first sign is usually a rusted mechanism rather than a tripped breaker. If the switch has to live outdoors, the 3R version of the same rating is the one to order. Matching generator. At 240V with an 0.8 power factor this switch carries approximately 307 kW of load (1600 A Γ— 240V Γ— 0.8 = 307.2 kW, single-phase two-wire). Size the standby generator so that its standby rating meets or exceeds that figure, and confirm the generator's two-wire automatic-start contacts are compatible with the transfer switch controller. Controller. This unit carries the ASCO Group G controller: a 128 Γ— 64 graphical LCD with switch-position, source-availability, common-alarm and not-in-auto indication. Transfer and re-transfer delays, engine cool-down and the in-phase transfer timer are all set from the membrane keypad rather than from DIP switches, with ranges up to 60 min 59 s. The Group G controller supports both open transition and delayed transition, and accessory 11BE adds RS-485 communication at 9,600–115,200 bps, a seven-period programmable exerciser and a 300-event log. Three-pole configuration. The three phase conductors are switched with a solid neutral. This is the standard arrangement where the neutral is bonded at the service and must not be opened by the transfer switch. Supply. Supplied as a genuine ASCO Power Technologies (Schneider Electric) unit, brand new and factory original, packed for export from our Dongguan warehouse. Ask us for the outline drawing, wiring diagram and data sheet for this exact catalog number.

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com

Jinjia Power, Quality Assured

Frequently Asked Questions

What is the 3ATSB31600FG0C transfer switch rated for?

The 3ATSB31600FG0C is rated 1600 A at 240V, 3-pole. It is a Automatic Transfer Switch (ATS) built on ASCO Series 300.

What type of transfer switch is the 3ATSB31600FG0C?

3ATSB31600FG0C is a Automatic Transfer Switch (ATS) in the ASCO Series 300 family with Open Transition.

Which generators can the 3ATSB31600FG0C be used with?

The 3ATSB31600FG0C is specified for Two-wire automatic-start generators. Match the switch ampere rating to the generator output current and confirm the voltage and pole configuration before ordering.

What controller does the 3ATSB31600FG0C use?

The 3ATSB31600FG0C uses Group G. The controller supervises the normal and emergency sources and drives the transfer sequence.

What enclosure does the 3ATSB31600FG0C come in?

The 3ATSB31600FG0C is supplied in NEMA 1 (Indoor). Confirm the enclosure rating against your installation environment, indoor or outdoor, before ordering.

Is the neutral on the 3ATSB31600FG0C solid or switched?

The 3ATSB31600FG0C is supplied with Switched Neutral. This matters on systems with ground fault protection, where a switched neutral is normally required.

Does the 3ATSB31600FG0C provide load disconnect contacts?

Yes. The 3ATSB31600FG0C provides 5 A resistive at 30 VDC max / 100 mA at 5 VDC min, which can be used for signalling or to interlock downstream equipment.

What communication options are available on the 3ATSB31600FG0C?

The 3ATSB31600FG0C offers RS-485, 9,600–11,5200 bps, address 1–247. This allows transfer status and source availability to be reported to a building management or monitoring system.

What certifications and standards does the 3ATSB31600FG0C meet?

3ATSB31600FG0C is certified to UL 1008 Listed. It is designed and tested to NEC / NFPA 70 Articles 700, 701 and 702. Request the current certificate for your project file before submission.

How many poles does the 3ATSB31600FG0C have?

The 3ATSB31600FG0C is a 3-pole device. Pole count must match your distribution: single phase two wire, three phase three wire, or three phase four wire with neutral.

What frequency does the 3ATSB31600FG0C operate at?

The 3ATSB31600FG0C is rated for 50 / 60 Hz. Confirm the generator and the utility supply are on the same frequency before installation.

Who makes the 3ATSB31600FG0C and what is the supply status?

3ATSB31600FG0C is manufactured by ASCO Power Technologies (Schneider Electric). Current availability: IN STOCK β€” same-day shipping, worldwide. Condition: Brand New, Certified Factory Original. Warranty: 1 Year.