86-0769-89610677 / 86-13553838770 | info@jinjiadongli.com
Home > TRANSFER SWITCHES > 3ATSB31000DG0C Series 300 - ASCO | Automatic, 1000 AMP
3ATSB31000DG0C Series 300 - ASCO | Automatic, 1000 AMP
Generator Gearbox AssemblyGenerator Gearbox AssemblyGenerator Gearbox AssemblyGenerator Gearbox AssemblyGenerator Gearbox Assembly

3ATSB31000DG0C Series 300 - ASCO | Automatic, 1000 AMP

3ATSB31000DG0C

Status: IN STOCK, Same day shipping Worldwide available | Brand New, Certified Factory Original

* Contact us for pricing and full specifications

πŸ“ž Get a Quote:86-13553838770
← Back to products

Specifications

Catalog Number3ATSB31000DG0C
SeriesASCO Series 300
Product TypeAutomatic Transfer Switch (ATS)
Ampere Rating1000 A
Number of Poles3 Poles
Voltage Rating220V
Neutral ConfigurationSwitched Neutral
Frequency50 / 60 Hz
EnclosureNEMA 1 (Indoor)
Transition TypeOpen Transition
ControllerGroup G
CertificationUL 1008 Listed
Applicable StandardNEC / NFPA 70 Articles 700, 701 and 702
Generator CompatibilityTwo-wire automatic-start generators
Load Disconnect Contact5 A resistive at 30 VDC max / 100 mA at 5 VDC min
Communication (opt. 11BE)RS-485, 9,600–11,5200 bps, address 1–247
ManufacturerASCO Power Technologies (Schneider Electric)
AvailabilityIN STOCK β€” same-day shipping, worldwide
ConditionBrand New, Certified Factory Original
Warranty1 Year

Product Overview

The ASCO Series 300 is a UL 1008-listed automatic transfer switch built for commercial, institutional and light-industrial standby power. It monitors both the utility and the generator source and transfers the load automatically when the normal source falls outside acceptable limits, then returns it once the utility is restored and stable. This unit is rated 1000 A, 220V, 3-pole, NEMA 1, open transition. Typical loads are a central plant, a multi-tenant distribution section, a water or wastewater pump station, or a process line β€” installations where the switch is a free-standing assembly and fault coordination with the service equipment matters as much as the transfer function. The NEMA 1 enclosure is intended for indoor installation in a dry, protected space such as a mechanical room or an electrical closet. Terminations and footprint. Four conductors per pole from 1/0 AWG to 600 kcmil in the 34 in by 72 in by 20 in assembly, 431 to 489 lb. 1,000 A is a whole-building rating β€” a mid-size office, a clinic, a light manufacturing line β€” and the switch is engineered around busbar and cable-lug terminations rather than around a single feeder. The neutral assembly on a four-wire system is a full-size bar, not a strap, and it has to be landed with the same care as the phases. Neutral configuration. The neutral is switched β€” it opens and closes with the phase poles as one more pole. You need this when the generator is wired as a separately derived source with its own grounding electrode and its own main bonding jumper: leaving the neutral solid would tie the two grounding systems together through the neutral, put objectionable current on the grounding conductor and leave the generator frame at a potential above earth during a fault. It costs one more pole and one more set of contacts to maintain, but on a separately derived system it is not optional, and an inspector will look for it. Enclosure. The Type 1 cabinet is for indoor use in a dry, protected space β€” a mechanical room, an electrical closet, a plant room β€” where the only thing it has to keep out is incidental dust and the occasional touch. It is not rain-tight and not watertight: mounting one on an exterior wall, even under a soffit, invites water in through the door seam and the conduit knockouts, and the first sign is usually a rusted mechanism rather than a tripped breaker. If the switch has to live outdoors, the 3R version of the same rating is the one to order. Matching generator. At 220V with an 0.8 power factor this switch carries approximately 192 kW of load (1000 A Γ— 220V Γ— 0.8 = 192.0 kW, single-phase two-wire). Size the standby generator so that its standby rating meets or exceeds that figure, and confirm the generator's two-wire automatic-start contacts are compatible with the transfer switch controller. Controller. This unit carries the ASCO Group G controller: a 128 Γ— 64 graphical LCD with switch-position, source-availability, common-alarm and not-in-auto indication. Transfer and re-transfer delays, engine cool-down and the in-phase transfer timer are all set from the membrane keypad rather than from DIP switches, with ranges up to 60 min 59 s. The Group G controller supports both open transition and delayed transition, and accessory 11BE adds RS-485 communication at 9,600–115,200 bps, a seven-period programmable exerciser and a 300-event log. Three-pole configuration. The three phase conductors are switched with a solid neutral. This is the standard arrangement where the neutral is bonded at the service and must not be opened by the transfer switch. Supply. Supplied as a genuine ASCO Power Technologies (Schneider Electric) unit, brand new and factory original, packed for export from our Dongguan warehouse. Ask us for the outline drawing, wiring diagram and data sheet for this exact catalog number.

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com

Jinjia Power, Quality Assured