86-0769-89610677 / 86-13553838770 | info@jinjiadongli.com
Home > TRANSFER SWITCHES > 3ATSB30600FG0F Series 300 - ASCO | Automatic, 600 AMP
3ATSB30600FG0F Series 300 - ASCO | Automatic, 600 AMP
Generator Control PanelGenerator Control PanelGenerator Control PanelGenerator Control PanelGenerator Control Panel

3ATSB30600FG0F Series 300 - ASCO | Automatic, 600 AMP

3ATSB30600FG0F

Status: IN STOCK, Same day shipping Worldwide available | Brand New, Certified Factory Original

Volume, OEM and project pricing available on request.

πŸ“ž Get a Quote:86-13553838770
← Back to products

Specifications

Catalog Number3ATSB30600FG0F
SeriesASCO Series 300
Product TypeAutomatic Transfer Switch (ATS)
Ampere Rating600 A
Number of Poles3 Poles
Voltage Rating240V
Neutral ConfigurationSwitched Neutral
Frequency50 / 60 Hz
EnclosureNEMA 3R (Outdoor Rain-tight)
Transition TypeOpen Transition
ControllerGroup G
CertificationUL 1008 Listed
Applicable StandardNEC / NFPA 70 Articles 700, 701 and 702
Generator CompatibilityTwo-wire automatic-start generators
Load Disconnect Contact5 A resistive at 30 VDC max / 100 mA at 5 VDC min
Communication (opt. 11BE)RS-485, 9,600–11,5200 bps, address 1–247
ManufacturerASCO Power Technologies (Schneider Electric)
AvailabilityIN STOCK β€” same-day shipping, worldwide
ConditionBrand New, Certified Factory Original
Warranty1 Year

Product Overview

The ASCO Series 300 is a UL 1008-listed automatic transfer switch built for commercial, institutional and light-industrial standby power. It monitors both the utility and the generator source and transfers the load automatically when the normal source falls outside acceptable limits, then returns it once the utility is restored and stable. This unit is rated 600 A, 240V, 3-pole, NEMA 3R, open transition. Typical loads are a central plant, a multi-tenant distribution section, a water or wastewater pump station, or a process line β€” installations where the switch is a free-standing assembly and fault coordination with the service equipment matters as much as the transfer function. The NEMA 3R enclosure is rain-tight and rated for outdoor mounting against a wall or on a pad, so the switch can sit next to an exterior generator without an additional weather shelter. Terminations and footprint. Two conductors per pole from 2/0 AWG to 600 kcmil, in a 24 in by 63 in by 17 in free-standing enclosure weighing 300 to 320 lb. At 600 A the switch normally sits on a housekeeping pad beside the service equipment rather than on a wall, the feeder is pulled with a rope and a tugger, and the terminations are laid out so they stay reachable with the line side energised. Two 600 kcmil per phase is a stiff pull β€” plan the conduit body and the bend radius before the concrete is poured. Service arrangement. Three-pole on a 240 V delta system: three ungrounded conductors with no usable neutral for line-to-neutral loads, still common in older industrial plants, farms, grain elevators and water districts where the service was built around motor loads. A delta service may be corner-grounded, so confirm the bonding jumper arrangement before dropping this switch into an existing service β€” it is the one voltage in this range where the neutral question is not academic. Neutral configuration. The neutral is switched β€” it opens and closes with the phase poles as one more pole. You need this when the generator is wired as a separately derived source with its own grounding electrode and its own main bonding jumper: leaving the neutral solid would tie the two grounding systems together through the neutral, put objectionable current on the grounding conductor and leave the generator frame at a potential above earth during a fault. It costs one more pole and one more set of contacts to maintain, but on a separately derived system it is not optional, and an inspector will look for it. Enclosure. The Type 3R cabinet is rain-tight, not watertight: it is built for outdoor mounting against a wall or on a pad, with a hooded or sloped top that sheds water and a gasketed door that keeps driven rain out. What it does not do is keep out dust or hose spray, and the installation still has to do its part β€” conduit entries need drip loops or sealing hubs so water running down the conduit cannot track into the enclosure, and the mounting surface has to drain. A 3R unit on a north wall in a coastal yard will outlast three indoor units in the same spot, which is why it is the default for anything not under a roof. Matching generator. At 240V with an 0.8 power factor this switch carries approximately 115 kW of load (600 A Γ— 240V Γ— 0.8 = 115.2 kW, single-phase two-wire). Size the standby generator so that its standby rating meets or exceeds that figure, and confirm the generator's two-wire automatic-start contacts are compatible with the transfer switch controller. Controller. This unit carries the ASCO Group G controller: a 128 Γ— 64 graphical LCD with switch-position, source-availability, common-alarm and not-in-auto indication. Transfer and re-transfer delays, engine cool-down and the in-phase transfer timer are all set from the membrane keypad rather than from DIP switches, with ranges up to 60 min 59 s. The Group G controller supports both open transition and delayed transition, and accessory 11BE adds RS-485 communication at 9,600–115,200 bps, a seven-period programmable exerciser and a 300-event log. Three-pole configuration. The three phase conductors are switched with a solid neutral. This is the standard arrangement where the neutral is bonded at the service and must not be opened by the transfer switch. Supply. Supplied as a genuine ASCO Power Technologies (Schneider Electric) unit, brand new and factory original, packed for export from our Dongguan warehouse. Ask us for the outline drawing, wiring diagram and data sheet for this exact catalog number.

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com

Jinjia Power, Quality Assured

Frequently Asked Questions

What is the 3ATSB30600FG0F transfer switch rated for?

The 3ATSB30600FG0F is rated 600 A at 240V, 3-pole. It is a Automatic Transfer Switch (ATS) built on ASCO Series 300.

What type of transfer switch is the 3ATSB30600FG0F?

3ATSB30600FG0F is a Automatic Transfer Switch (ATS) in the ASCO Series 300 family with Open Transition.

Which generators can the 3ATSB30600FG0F be used with?

The 3ATSB30600FG0F is specified for Two-wire automatic-start generators. Match the switch ampere rating to the generator output current and confirm the voltage and pole configuration before ordering.

What controller does the 3ATSB30600FG0F use?

The 3ATSB30600FG0F uses Group G. The controller supervises the normal and emergency sources and drives the transfer sequence.

What enclosure does the 3ATSB30600FG0F come in?

The 3ATSB30600FG0F is supplied in NEMA 3R (Outdoor Rain-tight). Confirm the enclosure rating against your installation environment, indoor or outdoor, before ordering.

Is the neutral on the 3ATSB30600FG0F solid or switched?

The 3ATSB30600FG0F is supplied with Switched Neutral. This matters on systems with ground fault protection, where a switched neutral is normally required.

Does the 3ATSB30600FG0F provide load disconnect contacts?

Yes. The 3ATSB30600FG0F provides 5 A resistive at 30 VDC max / 100 mA at 5 VDC min, which can be used for signalling or to interlock downstream equipment.

What communication options are available on the 3ATSB30600FG0F?

The 3ATSB30600FG0F offers RS-485, 9,600–11,5200 bps, address 1–247. This allows transfer status and source availability to be reported to a building management or monitoring system.

What certifications and standards does the 3ATSB30600FG0F meet?

3ATSB30600FG0F is certified to UL 1008 Listed. It is designed and tested to NEC / NFPA 70 Articles 700, 701 and 702. Request the current certificate for your project file before submission.

How many poles does the 3ATSB30600FG0F have?

The 3ATSB30600FG0F is a 3-pole device. Pole count must match your distribution: single phase two wire, three phase three wire, or three phase four wire with neutral.

What frequency does the 3ATSB30600FG0F operate at?

The 3ATSB30600FG0F is rated for 50 / 60 Hz. Confirm the generator and the utility supply are on the same frequency before installation.

Who makes the 3ATSB30600FG0F and what is the supply status?

3ATSB30600FG0F is manufactured by ASCO Power Technologies (Schneider Electric). Current availability: IN STOCK β€” same-day shipping, worldwide. Condition: Brand New, Certified Factory Original. Warranty: 1 Year.