Specifications

Catalog Number3ATSA30600NG0C
SeriesASCO Series 300
Product TypeAutomatic Transfer Switch (ATS)
Ampere Rating600 A
Number of Poles3 Poles
Voltage Rating480V
Neutral ConfigurationSolid Neutral
Frequency50 / 60 Hz
EnclosureNEMA 1 (Indoor)
Transition TypeOpen Transition
ControllerGroup G
CertificationUL 1008 Listed
Applicable StandardNEC / NFPA 70 Articles 700, 701 and 702
Generator CompatibilityTwo-wire automatic-start generators
Load Disconnect Contact5 A resistive at 30 VDC max / 100 mA at 5 VDC min
Communication (opt. 11BE)RS-485, 9,600–11,5200 bps, address 1–247
ManufacturerASCO Power Technologies (Schneider Electric)
AvailabilityIN STOCK β€” same-day shipping, worldwide
ConditionBrand New, Certified Factory Original
Warranty1 Year

Product Overview

The ASCO Series 300 is a UL 1008-listed automatic transfer switch built for commercial, institutional and light-industrial standby power. It monitors both the utility and the generator source and transfers the load automatically when the normal source falls outside acceptable limits, then returns it once the utility is restored and stable. This unit is rated 600 A, 480V, 3-pole, NEMA 1, open transition. Typical loads are a central plant, a multi-tenant distribution section, a water or wastewater pump station, or a process line β€” installations where the switch is a free-standing assembly and fault coordination with the service equipment matters as much as the transfer function. The NEMA 1 enclosure is intended for indoor installation in a dry, protected space such as a mechanical room or an electrical closet. Terminations and footprint. Two conductors per pole from 2/0 AWG to 600 kcmil, in a 24 in by 63 in by 17 in free-standing enclosure weighing 300 to 320 lb. At 600 A the switch normally sits on a housekeeping pad beside the service equipment rather than on a wall, the feeder is pulled with a rope and a tugger, and the terminations are laid out so they stay reachable with the line side energised. Two 600 kcmil per phase is a stiff pull β€” plan the conduit body and the bend radius before the concrete is poured. Service arrangement. This is a 480Y/277 V three-phase four-wire switch, the standard industrial and large-commercial service in North America: 480 V for motors, chillers and process equipment, 277 V for lighting, with the neutral bonded at the service and carried solid through the transfer switch. This is the voltage at which arc-flash energy climbs fastest, so the upstream coordination study matters more here than at 208 V. Neutral configuration. The grounded conductor is solid: it runs straight through on a bolted neutral plate and is never opened. That is the correct choice when the transfer switch is not a separately derived source β€” the generator neutral is bonded to the same grounding electrode system as the utility, so the neutral is one continuous current-carrying conductor end to end and breaking it would serve no purpose. It is also the cheaper of the two arrangements and has one fewer set of moving contacts to inspect, which is why it is the default on most commercial retrofits where the existing service neutral is already bonded. Enclosure. The Type 1 cabinet is for indoor use in a dry, protected space β€” a mechanical room, an electrical closet, a plant room β€” where the only thing it has to keep out is incidental dust and the occasional touch. It is not rain-tight and not watertight: mounting one on an exterior wall, even under a soffit, invites water in through the door seam and the conduit knockouts, and the first sign is usually a rusted mechanism rather than a tripped breaker. If the switch has to live outdoors, the 3R version of the same rating is the one to order. Matching generator. At 480V with an 0.8 power factor this switch carries approximately 399 kW of load (600 A Γ— 480V Γ— √3 Γ— 0.8 = 399 kW, three-phase). Size the standby generator so that its standby rating meets or exceeds that figure, and confirm the generator's two-wire automatic-start contacts are compatible with the transfer switch controller. Controller. This unit carries the ASCO Group G controller: a 128 Γ— 64 graphical LCD with switch-position, source-availability, common-alarm and not-in-auto indication. Transfer and re-transfer delays, engine cool-down and the in-phase transfer timer are all set from the membrane keypad rather than from DIP switches, with ranges up to 60 min 59 s. The Group G controller supports both open transition and delayed transition, and accessory 11BE adds RS-485 communication at 9,600–115,200 bps, a seven-period programmable exerciser and a 300-event log. Three-pole configuration. The three phase conductors are switched with a solid neutral. This is the standard arrangement where the neutral is bonded at the service and must not be opened by the transfer switch. Supply. Supplied as a genuine ASCO Power Technologies (Schneider Electric) unit, brand new and factory original, packed for export from our Dongguan warehouse. Ask us for the outline drawing, wiring diagram and data sheet for this exact catalog number.

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com

Jinjia Power, Quality Assured

Frequently Asked Questions

What is the 3ATSA30600NG0C transfer switch rated for?

The 3ATSA30600NG0C is rated 600 A at 480V, 3-pole. It is a Automatic Transfer Switch (ATS) built on ASCO Series 300.

What type of transfer switch is the 3ATSA30600NG0C?

3ATSA30600NG0C is a Automatic Transfer Switch (ATS) in the ASCO Series 300 family with Open Transition.

Which generators can the 3ATSA30600NG0C be used with?

The 3ATSA30600NG0C is specified for Two-wire automatic-start generators. Match the switch ampere rating to the generator output current and confirm the voltage and pole configuration before ordering.

What controller does the 3ATSA30600NG0C use?

The 3ATSA30600NG0C uses Group G. The controller supervises the normal and emergency sources and drives the transfer sequence.

What enclosure does the 3ATSA30600NG0C come in?

The 3ATSA30600NG0C is supplied in NEMA 1 (Indoor). Confirm the enclosure rating against your installation environment, indoor or outdoor, before ordering.

Is the neutral on the 3ATSA30600NG0C solid or switched?

The 3ATSA30600NG0C is supplied with Solid Neutral. This matters on systems with ground fault protection, where a switched neutral is normally required.

Does the 3ATSA30600NG0C provide load disconnect contacts?

Yes. The 3ATSA30600NG0C provides 5 A resistive at 30 VDC max / 100 mA at 5 VDC min, which can be used for signalling or to interlock downstream equipment.

What communication options are available on the 3ATSA30600NG0C?

The 3ATSA30600NG0C offers RS-485, 9,600–11,5200 bps, address 1–247. This allows transfer status and source availability to be reported to a building management or monitoring system.

What certifications and standards does the 3ATSA30600NG0C meet?

3ATSA30600NG0C is certified to UL 1008 Listed. It is designed and tested to NEC / NFPA 70 Articles 700, 701 and 702. Request the current certificate for your project file before submission.

How many poles does the 3ATSA30600NG0C have?

The 3ATSA30600NG0C is a 3-pole device. Pole count must match your distribution: single phase two wire, three phase three wire, or three phase four wire with neutral.

What frequency does the 3ATSA30600NG0C operate at?

The 3ATSA30600NG0C is rated for 50 / 60 Hz. Confirm the generator and the utility supply are on the same frequency before installation.

Who makes the 3ATSA30600NG0C and what is the supply status?

3ATSA30600NG0C is manufactured by ASCO Power Technologies (Schneider Electric). Current availability: IN STOCK β€” same-day shipping, worldwide. Condition: Brand New, Certified Factory Original. Warranty: 1 Year.