86-0769-89610677 / 86-13553838770 | info@jinjiadongli.com
Home > TRANSFER SWITCHES > 3ATSA20200FG0F Series 300 - ASCO | Automatic, 200 AMP
3ATSA20200FG0F Series 300 - ASCO | Automatic, 200 AMP
3ATSA20200FG0F ASCO 200 A3ATSA20200FG0F ASCO 200 A3ATSA20200FG0F ASCO 200 A3ATSA20200FG0F ASCO 200 A3ATSA20200FG0F ASCO 200 A

3ATSA20200FG0F Series 300 - ASCO | Automatic, 200 AMP

3ATSA20200FG0F

Status: IN STOCK, Same day shipping Worldwide available | Brand New, Certified Factory Original

Volume, OEM and project pricing available on request.

πŸ“ž Get a Quote:86-13553838770
← Back to products

Specifications

Catalog Number3ATSA20200FG0F
SeriesASCO Series 300
Product TypeAutomatic Transfer Switch (ATS)
Ampere Rating200 A
Number of Poles2 Poles
Voltage Rating240V
Neutral ConfigurationSolid Neutral
Frequency50 / 60 Hz
EnclosureNEMA 3R (Outdoor Rain-tight)
Transition TypeOpen Transition
ControllerGroup G
CertificationUL 1008 Listed
Applicable StandardNEC / NFPA 70 Articles 700, 701 and 702
Generator CompatibilityTwo-wire automatic-start generators
Load Disconnect Contact5 A resistive at 30 VDC max / 100 mA at 5 VDC min
Communication (opt. 11BE)RS-485, 9,600–11,5200 bps, address 1–247
ManufacturerASCO Power Technologies (Schneider Electric)
AvailabilityIN STOCK β€” same-day shipping, worldwide
ConditionBrand New, Certified Factory Original
Warranty1 Year

Product Overview

The ASCO Series 300 is a UL 1008-listed automatic transfer switch built for commercial, institutional and light-industrial standby power. It monitors both the utility and the generator source and transfers the load automatically when the normal source falls outside acceptable limits, then returns it once the utility is restored and stable. This unit is rated 200 A, 240V, 2-pole, NEMA 3R, open transition. Typical loads are a whole-building distribution panel, a rooftop packaged unit group, a small data or telecom room, a clinic or a restaurant β€” installations where the transfer switch is sized to the full service and must coordinate with the upstream overcurrent protection. The NEMA 3R enclosure is rain-tight and rated for outdoor mounting against a wall or on a pad, so the switch can sit next to an exterior generator without an additional weather shelter. Terminations and footprint. One conductor per pole, #14 AWG to 4/0 AWG, in the 18 in by 31 in by 13 in cabinet at roughly 75 lb. 200 A is the standard light-commercial service size and the point where the switch normally covers the entire board β€” lighting, receptacles and a small mechanical load β€” rather than a selected group. The wide lug range means the same unit accepts a #6 feeder or a 4/0, which is useful when a service is upgraded later without replacing the switch. Service arrangement. Two-pole 120/240 V single-phase: two ungrounded conductors and a grounded neutral, the arrangement behind nearly every North American dwelling and behind small shops on a split-phase service. Only two poles switch, so a solid-neutral unit carries the grounded conductor straight through while a switched-neutral unit opens it β€” which is what you want when the generator is treated as a separately derived source and the neutral must be broken to keep the two grounding electrodes apart. Neutral configuration. The grounded conductor is solid: it runs straight through on a bolted neutral plate and is never opened. That is the correct choice when the transfer switch is not a separately derived source β€” the generator neutral is bonded to the same grounding electrode system as the utility, so the neutral is one continuous current-carrying conductor end to end and breaking it would serve no purpose. It is also the cheaper of the two arrangements and has one fewer set of moving contacts to inspect, which is why it is the default on most commercial retrofits where the existing service neutral is already bonded. Enclosure. The Type 3R cabinet is rain-tight, not watertight: it is built for outdoor mounting against a wall or on a pad, with a hooded or sloped top that sheds water and a gasketed door that keeps driven rain out. What it does not do is keep out dust or hose spray, and the installation still has to do its part β€” conduit entries need drip loops or sealing hubs so water running down the conduit cannot track into the enclosure, and the mounting surface has to drain. A 3R unit on a north wall in a coastal yard will outlast three indoor units in the same spot, which is why it is the default for anything not under a roof. Matching generator. At 240V with an 0.8 power factor this switch carries approximately 38 kW of load (200 A Γ— 240V Γ— 0.8 = 38.4 kW, single-phase two-wire). Size the standby generator so that its standby rating meets or exceeds that figure, and confirm the generator's two-wire automatic-start contacts are compatible with the transfer switch controller. Controller. This unit carries the ASCO Group G controller: a 128 Γ— 64 graphical LCD with switch-position, source-availability, common-alarm and not-in-auto indication. Transfer and re-transfer delays, engine cool-down and the in-phase transfer timer are all set from the membrane keypad rather than from DIP switches, with ranges up to 60 min 59 s. The Group G controller supports both open transition and delayed transition, and accessory 11BE adds RS-485 communication at 9,600–115,200 bps, a seven-period programmable exerciser and a 300-event log. Two-pole configuration. Both the hot and the neutral are switched, which is the normal choice for 120/240 V single-phase residential and light-commercial services and for any circuit derived from a separately derived source. Supply. Supplied as a genuine ASCO Power Technologies (Schneider Electric) unit, brand new and factory original, packed for export from our Dongguan warehouse. Ask us for the outline drawing, wiring diagram and data sheet for this exact catalog number.

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com

Jinjia Power, Quality Assured

Frequently Asked Questions

What is the 3ATSA20200FG0F transfer switch rated for?

The 3ATSA20200FG0F is rated 200 A at 240V, 2-pole. It is a Automatic Transfer Switch (ATS) built on ASCO Series 300.

What type of transfer switch is the 3ATSA20200FG0F?

3ATSA20200FG0F is a Automatic Transfer Switch (ATS) in the ASCO Series 300 family with Open Transition.

Which generators can the 3ATSA20200FG0F be used with?

The 3ATSA20200FG0F is specified for Two-wire automatic-start generators. Match the switch ampere rating to the generator output current and confirm the voltage and pole configuration before ordering.

What controller does the 3ATSA20200FG0F use?

The 3ATSA20200FG0F uses Group G. The controller supervises the normal and emergency sources and drives the transfer sequence.

What enclosure does the 3ATSA20200FG0F come in?

The 3ATSA20200FG0F is supplied in NEMA 3R (Outdoor Rain-tight). Confirm the enclosure rating against your installation environment, indoor or outdoor, before ordering.

Is the neutral on the 3ATSA20200FG0F solid or switched?

The 3ATSA20200FG0F is supplied with Solid Neutral. This matters on systems with ground fault protection, where a switched neutral is normally required.

Does the 3ATSA20200FG0F provide load disconnect contacts?

Yes. The 3ATSA20200FG0F provides 5 A resistive at 30 VDC max / 100 mA at 5 VDC min, which can be used for signalling or to interlock downstream equipment.

What communication options are available on the 3ATSA20200FG0F?

The 3ATSA20200FG0F offers RS-485, 9,600–11,5200 bps, address 1–247. This allows transfer status and source availability to be reported to a building management or monitoring system.

What certifications and standards does the 3ATSA20200FG0F meet?

3ATSA20200FG0F is certified to UL 1008 Listed. It is designed and tested to NEC / NFPA 70 Articles 700, 701 and 702. Request the current certificate for your project file before submission.

How many poles does the 3ATSA20200FG0F have?

The 3ATSA20200FG0F is a 2-pole device. Pole count must match your distribution: single phase two wire, three phase three wire, or three phase four wire with neutral.

What frequency does the 3ATSA20200FG0F operate at?

The 3ATSA20200FG0F is rated for 50 / 60 Hz. Confirm the generator and the utility supply are on the same frequency before installation.

Who makes the 3ATSA20200FG0F and what is the supply status?

3ATSA20200FG0F is manufactured by ASCO Power Technologies (Schneider Electric). Current availability: IN STOCK β€” same-day shipping, worldwide. Condition: Brand New, Certified Factory Original. Warranty: 1 Year.