Home > MOBILE GENERATORS > 61 KW EPA Tier 4 Generator, Industrial
Trailer Mounted Silent Generator 61 kW FTP Iveco

61 KW EPA Tier 4 Mobile Generator, GPM-F60-60T4F-2SA

GPM-F60-60T4F-2SA

Status: In Stock | Brand New, 2 Years International Warranty

Volume, OEM and project pricing available on request.

📞 Get a Quote:86-13553838770
← Back to products

Specifications

SKUGPM-F60-60T4F-2SA
AvailabilityIn Stock
ConditionBrand New, 1 Year / 2000 Hours Prime Service Duty
EPA ComplianceEPA / CARB Tier 4 Final
Standby Power (ESP)61 kW / 77 kVA
Prime Power (PRP)56 kW / 70 kVA
Voltage / Phase480/277 V, 208/120 V (3 Phase) | 240/120 V (1 Phase) — 60 Hz, 0.8 PF
Engine MakeFTP / IVECO (Italy)
Engine ModelFTP (IVECO) F34ETZK02.A73, 4-Cylinder, Turbocharged & Air-to-Air Cooled, 1800 RPM, Electronic Isochronous Governor
Emissions AftertreatmentDOC + EGR + SCR Only — No DPF, No Regeneration, EPA / CARB Tier 4 Final
DEF Tank5.2 Gal (20 L), 26 Hours Runtime @ 100% PRP
AlternatorStamford Cummins UCI224F, 12-Lead Brushless, PMG Auxiliary Excitation, Full Load Rated, Class H, Self-Ventilated Drip-Proof, Electronic AVR
ControllerDeep Sea Electronics DSE7320 MKII, 4-Line Backlit LCD with On-Screen Line Diagram, 50-Event Log, UL Listed
Circuit BreakerABB 250 A, 3-Pole, Manual Main Line
Fuel Tank175 Gal (662 L), Double-Walled Integral Metallic Tank, 110% Containment, Leak Detection Switch, Electronic Level Sender
Fuel ConsumptionApprox. 16.0 L/hr (4.2 Gal/hr) @ 100% Prime Load
Runtime Autonomy37 Hours @ 100% Load | 49 Hours @ 75% Load
Overall Dimensions4,623 × 2,286 × 2,863 mm (L × W × H, with Lifting Kit + Trailer) | 2,963 × 1,136 × 2,111 mm (with Lifting Kit, without Trailer)
Dry WeightApprox. 2,050 kg (4,520 lb) without trailer — exact weight per configuration
Sound LevelMeets & Exceeds North America Level 2 / EU 2000/14/EC; Approx. 67 dB(A) @ 7 m
TrailerD.O.T. Compliant, 10,400 lbs GVWR, 2-Axle Tandem with Electric Brakes
EnclosureMarine-Grade Aluminium, IP56, Super Silent, Up to 50 mm Acoustical Foam
Rental Features3-Position Manual Voltage Selector, Full Distribution Panel with Camlocks, External Shore Power Connector, 4× Quick-Access Service Ports, Recessed Emergency Stop, Battery Disconnect, 12 VDC Shunt Trip
StandardsQuality management to ISO 9001; ISO 3046, ISO 8528, BS4999, BS5514, BS5000PT99, AS1359, IEC 34, UTE 5100, VDE 0530

Product Overview

61KW 77KVA FTP (IVECO) POWERED MOBILE GENERATOR, “EPA/CARB TIER 4 FINAL” -BRAND NEW -MARINE-GRADE ALUMINUM ENCLOSURE GENERATOR POWER RATINGS: -61KW (77KVA) STANDBY, 56KW (70KVA) PRIME, 0.8PF, 60HZ, XXX/XXXV EMISSIONS COMPLIANCE: -U.S. EPA CARB TIER 4 FINAL compliant engine for Stationary Emergency, Stationary Prime, and Mobile Prime application as per current U.S. Environmental Protection Agency regulations POWERED BY A HEAVY DUTY INDUSTRIAL ENGINE FOR MAXIMUM DURABILITY, EXCELLENT RELIABILITY AND WORLDWIDE SUPPORT: -FTP (IVECO) F34ETZK02.A73, 1800RPM, Turbocharged, air-to-air cooled -Electronic isochronous governor -Industrial-grade cooling system with fan guards and coolant drain extension with in-line valve -DOC+EGR+SCR-only exhaust aftertreatment system. No DPF or regeneration -5.2GAL (20L) DEF tank, 26-hours runtime @ 100% PRP PREMIUM INDUSTRIAL-GRADE ALTERNATOR: -STAMFORD UCI224F, 12 Leads, brushless -Permanent Magnet Generator auxiliary excitation system (PMG) -Full load rated with thermo-magnetic switch protection -Skewed rotor and 2/3 pitch winding suppress triple harmonics and guarantee a superior voltage waveform -Class H Insulation and Self-ventilated drip-proof design -Electronic automatic voltage regulation ADVANCED DIGITAL CONTROLLER: -DEEP SEA ELECTRONIC DSE7320MKII, Microprocessor based generator controller, UL listed. -User-friendly, 4-line back light LCD icon display, with on-screen line-diagram functionality. -Manual, TEST, and Auto Operation Mode, with 2-wire remote start/stop capability. -50 event log & 50+ Engine/ECU/Alternators alarms. Warning, Electrical Trip and Shutdown Alarms. 105-GAL, DOUBLE-WALLED, INTEGRAL METALLIC FUEL TANK FOR DAILY AUTONOMY: -32-hours runtime autonomy @ 75% PRP -24-hours runtime autonomy @ 100% PRP -Electronic fuel level sender -Programmable low-level, high-level alarms and shutdowns RENTAL-GRADE FEATURES FOR COMPLETE MOBILITY, TOTAL VERSATILITY AND MAXIMUM ROI: -DOUBLE-WALLED FUEL TANK: 175 Gal (662 L) (397L), double walled

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com

Jinjia Power, Quality Assured

Frequently Asked Questions

What are the standby and prime ratings of the 61 KW EPA Tier 4 Mobile Generator?

The 61 KW EPA Tier 4 Mobile Generator delivers 61 kW / 77 kVA standby, and 56 kW / 70 kVA prime per ISO 8528 duty definitions. Standby rating applies to emergency use under varying load; prime rating applies to continuous operation under a steady load.

What voltage and phase configuration does the 61 KW EPA Tier 4 Mobile Generator output?

The 61 KW EPA Tier 4 Mobile Generator is configured for 480/277 V, 208/120 V (3 Phase) | 240/120 V (1 Phase) — 60 Hz, 0.8 PF. Confirm the required voltage and phase before ordering, since the reconnectable alternator is set at the factory.

Which engine drives the 61 KW EPA Tier 4 Mobile Generator?

The 61 KW EPA Tier 4 Mobile Generator is powered by FTP / IVECO (Italy), model FTP (IVECO) F34ETZK02.A73, 4-Cylinder, Turbocharged & Air-to-Air Cooled, 1800 RPM, Electronic Isochronous Governor.

What alternator is fitted to the 61 KW EPA Tier 4 Mobile Generator?

The 61 KW EPA Tier 4 Mobile Generator uses Stamford Cummins UCI224F, 12-Lead Brushless, PMG Auxiliary Excitation, Full Load Rated, Class H, Self-Ventilated Drip-Proof, Electronic AVR. The alternator is matched to the engine output with margin for transient loads.

What controller does the 61 KW EPA Tier 4 Mobile Generator use?

The 61 KW EPA Tier 4 Mobile Generator is controlled by Deep Sea Electronics DSE7320 MKII, 4-Line Backlit LCD with On-Screen Line Diagram, 50-Event Log, UL Listed. The controller handles start, stop, protection shutdowns and mains failure changeover when an ATS is fitted.

What circuit breaker is supplied with the 61 KW EPA Tier 4 Mobile Generator?

The 61 KW EPA Tier 4 Mobile Generator is fitted with ABB 250 A, 3-Pole, Manual Main Line. Breaker rating is matched to the set output so the generator is protected against overload and short circuit.

How much fuel does the 61 KW EPA Tier 4 Mobile Generator carry?

The 61 KW EPA Tier 4 Mobile Generator has 175 Gal (662 L), Double-Walled Integral Metallic Tank, 110% Containment, Leak Detection Switch, Electronic Level Sender. Confirm the base tank meets your local containment rules before siting the set.

What is the fuel consumption of the 61 KW EPA Tier 4 Mobile Generator?

Fuel consumption on the 61 KW EPA Tier 4 Mobile Generator is Approx. 16.0 L/hr (4.2 Gal/hr) @ 100% Prime Load. Consumption rises with load, so size the tank against your expected duty cycle rather than the headline figure.

How long can the 61 KW EPA Tier 4 Mobile Generator run on a full tank?

The 61 KW EPA Tier 4 Mobile Generator runs for 37 Hours @ 100% Load | 49 Hours @ 75% Load. For longer outages, plan a bulk fuel supply or a refuelling schedule alongside the set.

What are the dimensions and weight of the 61 KW EPA Tier 4 Mobile Generator?

Dimensions: 4,623 × 2,286 × 2,863 mm (L × W × H, with Lifting Kit + Trailer) | 2,963 × 1,136 × 2,111 mm (with Lifting Kit, without Trailer). Dry weight: Approx. 2,050 kg (4,520 lb) without trailer — exact weight per configuration. Check access routes, crane capacity and floor loading before delivery.

How loud is the 61 KW EPA Tier 4 Mobile Generator?

Sound level on the 61 KW EPA Tier 4 Mobile Generator is Meets & Exceeds North America Level 2 / EU 2000/14/EC; Approx. 67 dB(A) @ 7 m. Site the set away from noise-sensitive boundaries and check local limits before installation.

Is the 61 KW EPA Tier 4 Mobile Generator available as a trailer mounted unit?

The 61 KW EPA Tier 4 Mobile Generator can be supplied trailer mounted: D.O.T. Compliant, 10,400 lbs GVWR, 2-Axle Tandem with Electric Brakes. Trailer configuration is normally chosen for rental fleets and site work where the set moves between locations.

What emission and standards compliance does the 61 KW EPA Tier 4 Mobile Generator carry?

Emission compliance: EPA / CARB Tier 4 Final. Design standards: Quality management to ISO 9001; ISO 3046, ISO 8528, BS4999, BS5514, BS5000PT99, AS1359, IEC 34, UTE 5100, VDE 0530.

What is the availability and warranty on the 61 KW EPA Tier 4 Mobile Generator?

The 61 KW EPA Tier 4 Mobile Generator is currently In Stock. Condition: Brand New, 1 Year / 2000 Hours Prime Service Duty. Request the current datasheet and test report with your quotation.

What applications suit the 61 KW EPA Tier 4 Mobile Generator?

The 61 KW EPA Tier 4 Mobile Generator suits standby duty for commercial buildings, industrial plant, telecom sites and rental fleets where a compact, trailer-mountable set is required. Load type and starting current determine the final rating choice.