Specifications

SKUGPR-P500-60T4F
AvailabilityIn Stock
ConditionBrand New, 1 Year / 2000 Hours Prime Service Duty
EPA ComplianceEPA / CARB Tier 4 Final
Standby Power (ESP)500 kW / 625 kVA
Prime Power (PRP)450 kW / 563 kVA
Rated Current752 A Standby / 677 A Prime @ 480/277 V | 1735 A / 1561 A @ 208/120 V
Voltage / Phase480/277 V, 208/120 V (3 Phase) | 240/120 V (1 Phase 270 kW) — 60 Hz, 0.8 PF
Engine MakePerkins (UK)
Engine ModelPerkins 2806F-E18TAG3, 6-Cylinder In-Line, 18.1 L, Bore × Stroke 145 × 183 mm, Compression Ratio 16.0:1, Turbocharged & Air-to-Air Aftercooled, 1800 RPM, 555 kW (744 HP), Electronic Governor
Emissions AftertreatmentDOC + SCR, EPA / CARB Tier 4 Final
AlternatorLeroy Somer TAL-47-D, 4-Pole, 3 Phase, 0.8 PF, AREP Auxiliary Winding Excitation, 250% / 5 s Short-Circuit Capability, Class H / H, Direct Single-Bearing Coupling
Voltage RegulatorDeep Sea DSEA109 Digital AVR, ±1.0% Voltage Regulation
ControllerDeep Sea Electronics DSE7310, UL Listed
Circuit BreakerABB T-Max Range, 3-Pole, Set Mounted, Maximum Output Rated
Fuel Tank600 Gal (2,271 L), 2-Wall NON-UL, 110% Containment
Fuel Consumption126.7 L/hr (33.5 Gal/hr) @ 100% Prime Load | 106.7 L/hr (28.2 Gal/hr) @ 75% Prime Load
Runtime Autonomy18 Hours @ 100% Load | 21 Hours @ 75% Load
DEF Tank24.7 Gal (93 L) Integral, 37 Hours @ 75% Load; DEF Consumption 2.5 L/hr (0.66 Gal/hr)
Overall Dimensions5,842 × 2,134 × 2,272 mm (L × W × H, Standard Silent Enclosure)
Dry WeightApprox. 8,000 kg (17,640 lb) — exact weight per configuration
Sound LevelMeets & Exceeds North America Level 2 / EU 2000/14/EC; Approx. 77 dB(A) @ 7 m
TrailerD.O.T. Compliant, 24,000 lbs GVWR, 3-Axle with Electric Brakes, 6× Bias 6-Ply Load Range C Tires, Pintle Ring Hitch, 10K Top Wind Tongue Jack, 2× 10K Side Wind Rear Jacks, 1/4" × 30" Safety Chains
EnclosureAL5052 12 GA Marine-Grade Aluminium, IP56, RAL9003 White Polyester Powder Coat, Level-2 Discharge Plenum, XXL Beam-Less Dual-Side Access
Power Distribution2× 20 A Duplex Outlets, 3× 50 A 125/250 V Twist Locks, 25× 400 A E1016 Female Camlocks, 5× 350 kcmil–6 AWG Mechanical Lugs
ProtectionANSI 27/59, ANSI 32, ANSI 50, ANSI 81, ANSI 87G Ground Fault, Over/Under Speed, High Coolant Temp, Low Oil Pressure, Low Coolant Level, Fuel Leak, Breaker Safety Switch, Voltage Selector Interlock
Load AcceptanceISO 8528-5 Class G3 (with electronic governor and digital AVR)

Product Overview

500 kW EPA Tier 4 Diesel Generator, Powered by USA-Made Perkins Engine, GPR-P500-60T4F Jinjia Power’s 500 kW EPA Tier 4 Generator is purpose-built for prime, rental, mobile, and towable operations. With a 625 kVA output capacity and Tier 4 Final emissions compliance, it’s engineered for tough job sites and long-hour demands. This generator is available in both trailer and stationary configurations to meet your specific operational needs. Specifications Power Rating: 500 kW / 625 kVA Standby; 450 kW / 563 kVA Prime Voltage Options: 3PH 480/277V; 3PH 208/120V; 1PH 240/120V Engine: Perkins (Caterpillar Group) 2806F-E18TAG3, Tier 4 Final, 1800 RPM, turbocharged & aftercooled Alternator: Leroy Somer TAL-047-D with enhanced auxiliary-excitation (AREP), and advanced digital voltage regulation Controller: DeepSea DSE7310 digital auto start/stop panel Enclosure: 12GA marine-grade aluminum, outdoor rated and super-silent design Fuel Tank: 600-gallon true double-walled with 21-hour runtime @ 75% load Circuit Breaker: ABB T-Max 3-pole manual breaker, maximum output rated Voltage Selector: Salzer 3-position manual switch (1PH/3PH) Distribution Panel: Includes GFCIs, twist-locks, camlocks, and bus bars USA-Made Quality and Engineered Performance This generator is 100% designed, engineered, assembled, and tested in the USA, built around a rugged Perkins 2806F-E18TAG3 engine. It’s turbocharged, aftercooled, and liquid-cooled with electronic governing for optimal performance. The brushless Leroy Somer TAL-047-D alternator with AREP excitation and DeepSea DSE7310 controller ensures reliable output, while digital voltage regulation with motor soft-start capability adds extra versatility. Advanced Rental-Grade Features and Safety The system includes a 600-gallon double-walled fuel tank offering up to 21 hours of autonomy at 75% load. A manual voltage selector switch allows effortless toggling between 1-phase and 3-phase voltages, and the rental-grade power distribution panel includes GFCIs, twist-locks

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com

Jinjia Power, Quality Assured

Frequently Asked Questions

What are the standby and prime ratings of the 500 KW EPA Tier 4 Generator?

The 500 KW EPA Tier 4 Generator delivers 500 kW / 625 kVA standby, and 450 kW / 563 kVA prime per ISO 8528 duty definitions. Standby rating applies to emergency use under varying load; prime rating applies to continuous operation under a steady load.

What voltage and phase configuration does the 500 KW EPA Tier 4 Generator output?

The 500 KW EPA Tier 4 Generator is configured for 480/277 V, 208/120 V (3 Phase) | 240/120 V (1 Phase 270 kW) — 60 Hz, 0.8 PF. Confirm the required voltage and phase before ordering, since the reconnectable alternator is set at the factory.

Which engine drives the 500 KW EPA Tier 4 Generator?

The 500 KW EPA Tier 4 Generator is powered by Perkins (UK), model Perkins 2806F-E18TAG3, 6-Cylinder In-Line, 18.1 L, Bore × Stroke 145 × 183 mm, Compression Ratio 16.0:1, Turbocharged & Air-to-Air Aftercooled, 1800 RPM, 555 kW (744 HP), Electronic Governor.

What alternator is fitted to the 500 KW EPA Tier 4 Generator?

The 500 KW EPA Tier 4 Generator uses Leroy Somer TAL-47-D, 4-Pole, 3 Phase, 0.8 PF, AREP Auxiliary Winding Excitation, 250% / 5 s Short-Circuit Capability, Class H / H, Direct Single-Bearing Coupling. The alternator is matched to the engine output with margin for transient loads.

How is voltage regulated on the 500 KW EPA Tier 4 Generator?

Voltage on the 500 KW EPA Tier 4 Generator is held by Deep Sea DSEA109 Digital AVR, ±1.0% Voltage Regulation, which keeps output steady as load steps on and off.

What controller does the 500 KW EPA Tier 4 Generator use?

The 500 KW EPA Tier 4 Generator is controlled by Deep Sea Electronics DSE7310, UL Listed. The controller handles start, stop, protection shutdowns and mains failure changeover when an ATS is fitted.

What circuit breaker is supplied with the 500 KW EPA Tier 4 Generator?

The 500 KW EPA Tier 4 Generator is fitted with ABB T-Max Range, 3-Pole, Set Mounted, Maximum Output Rated. Breaker rating is matched to the set output so the generator is protected against overload and short circuit.

How much fuel does the 500 KW EPA Tier 4 Generator carry?

The 500 KW EPA Tier 4 Generator has 600 Gal (2,271 L), 2-Wall NON-UL, 110% Containment. Confirm the base tank meets your local containment rules before siting the set.

What is the fuel consumption of the 500 KW EPA Tier 4 Generator?

Fuel consumption on the 500 KW EPA Tier 4 Generator is 126.7 L/hr (33.5 Gal/hr) @ 100% Prime Load | 106.7 L/hr (28.2 Gal/hr) @ 75% Prime Load. Consumption rises with load, so size the tank against your expected duty cycle rather than the headline figure.

How long can the 500 KW EPA Tier 4 Generator run on a full tank?

The 500 KW EPA Tier 4 Generator runs for 18 Hours @ 100% Load | 21 Hours @ 75% Load. For longer outages, plan a bulk fuel supply or a refuelling schedule alongside the set.

What are the dimensions and weight of the 500 KW EPA Tier 4 Generator?

Dimensions: 5,842 × 2,134 × 2,272 mm (L × W × H, Standard Silent Enclosure). Dry weight: Approx. 8,000 kg (17,640 lb) — exact weight per configuration. Check access routes, crane capacity and floor loading before delivery.

How loud is the 500 KW EPA Tier 4 Generator?

Sound level on the 500 KW EPA Tier 4 Generator is Meets & Exceeds North America Level 2 / EU 2000/14/EC; Approx. 77 dB(A) @ 7 m. Site the set away from noise-sensitive boundaries and check local limits before installation.

Is the 500 KW EPA Tier 4 Generator available as a trailer mounted unit?

The 500 KW EPA Tier 4 Generator can be supplied trailer mounted: D.O.T. Compliant, 24,000 lbs GVWR, 3-Axle with Electric Brakes, 6× Bias 6-Ply Load Range C Tires, Pintle Ring Hitch, 10K Top Wind Tongue Jack, 2× 10K Side Wind Rear Jacks, 1/4" × 30" Safety Chains. Trailer configuration is normally chosen for rental fleets and site work where the set moves between locations.

What emission and standards compliance does the 500 KW EPA Tier 4 Generator carry?

Emission compliance: EPA / CARB Tier 4 Final.

What is the availability and warranty on the 500 KW EPA Tier 4 Generator?

The 500 KW EPA Tier 4 Generator is currently In Stock. Condition: Brand New, 1 Year / 2000 Hours Prime Service Duty. Request the current datasheet and test report with your quotation.

What applications suit the 500 KW EPA Tier 4 Generator?

The 500 KW EPA Tier 4 Generator suits standby duty for commercial buildings, industrial plant, telecom sites and rental fleets where a compact, trailer-mountable set is required. Load type and starting current determine the final rating choice.