Model: K20U II
Power: 20KW 25KVA Standby / 18KW 23KVA Prime
Status: Brand New, 2 Years International Warranty
Volume, OEM and project pricing available on request.
| Model | K20U II |
| Brand | KOHLER |
| Series | K series (stationary, value) |
| Standby Output | 20 kW / 25 kVA (ESP) |
| Prime Output | 18 kW / 22 kVA (PRP) |
| Power Factor | 0.80 |
| Phase / Connection | Three phase, 4-wire (star) |
| Voltage | 400 V |
| Frequency | 50 Hz |
| Rated Speed | 1500 rpm |
| Current @ Standby | 36.1 A per line |
| Current @ Prime | 31.8 A per line |
| Engine | Kohler-SDMO diesel, 1500 rpm |
| Fuel Type | Diesel, EN 590 / ASTM D975 grade |
| Fuel Consumption @ 100% | 6.2 L/h (0.31 L/kWh) |
| Fuel Consumption @ 75% | 5.0 L/h |
| Fuel Consumption @ 50% | 4.2 L/h |
| Fuel Tank | Base-frame tank, typically 50-100 L depending on build |
| Runtime @ 75% Load | 10 hours on a 50 L base tank |
| Alternator | Brushless synchronous, 4-pole, single bearing, direct coupled |
| Insulation / Enclosure | Class H insulation, IP23 protection |
| Voltage Regulation | AVR, +/- 1% steady state, THD < 3% |
| Controller | Automatic panel, manual/auto selector, LCD metering, RS485 Modbus |
| Protection | Over-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence |
| Starting System | 12 V DC electric starter, 12 V charge alternator, battery included |
| Cooling | Radiator cooled, 40 C ambient design |
| Dimensions | Open skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation. |
| Dry Weight | Open skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation. |
| Noise Level | Soundproofed version typically 68-72 dB(A) @ 1 m |
| Enclosure Options | Open skid / weatherproof silent canopy / containerised / mobile trailer |
| Emission | Emission tier depends on the destination market and is confirmed per order — EU Stage V, US EPA Tier 4 Final, or unregulated where the market allows. |
| Standard | ISO 8528-1, performance class G1/G2; CE marking supported by the manufacturing plant's Declaration of Conformity |
| Warranty | 2 years or 2,000 hours, international coverage |
| Availability | IN STOCK, Same day shipping Worldwide available |
| Condition | Brand New, 2 Years International Warranty |
| Quality | Load bank tested in our Dongguan facility |
| Reliability | Made in China; factory load-bank tested |
K20U II at a glance. This is a 20 kW / 25 kVA standby, 18 kW / 22 kVA prime diesel generating set built on a Kohler-SDMO platform and wound for 400 V, 50 Hz three phase output at 1500 rpm. It sits in the small stationary class where the set is bought to carry a defined load block rather than to run a plant: a shop, a guesthouse, a telecom cabinet, a small cold store, a farm pump, or the essential circuit of a house. At this rating the physical size matters as much as the numbers, which is why the same machine is offered on an open skid and inside a canopy that fits through a standard doorway.
Reading the model code. K20U II decodes as the K prefix, the frame number 20 which tracks the kVA class, and the suffix string U. The K range shares the same Mitsubishi industrial base as the T range, with the same mechanical governor and 22:1 compression ratio, but is trimmed for a lower price point on the smaller ratings. In this case the U marks the uprated frame, which is why the same number appears with a higher kVA in the U version; the trailing II is the emission stage of the engine fitted, not a different alternator. Note that the frame number (20) is the base rating of the frame, not the kVA of this build: the suffix pushes it to 25 kVA, and that gap is the whole reason the suffix exists.
Why the kVA is bigger than the kW. This is a three-phase set rated at 0.8 power factor, so 20 kW standby corresponds to 25 kVA and the two figures differ by exactly the reactive component the alternator has to carry. Quoting only the kW understates the copper and the switchgear: cables, breaker and busbar all size on the 25 kVA and the 36.1 A line current, while the engine only ever sees the 20 kW. That split is the most common source of undersized installations on three-phase sets in this class.
Standby and prime are two different machines in one frame. ISO 8528 defines standby (ESP) as the maximum a set may deliver for up to 200 hours a year on a varying load, with no overload capability, and prime (PRP) as the continuous rating under a varying load for unlimited hours with a 10 per cent overload window. This set is 20 kW / 25 kVA standby and 18 kW / 22 kVA prime, so the gap between the two, 2.4 kW, is the margin the engine keeps for overload and for altitude and temperature derating. If the load runs for days rather than hours, quote against prime and treat the standby figure as a peak that must not be sustained.
What the nameplate means once it is wired in. At 25 kVA this set pushes 36.1 A down each line on a 400 V three-phase supply, and 31.8 A at the prime rating. Those currents, not the kVA figure, are what the switchgear and the cable have to survive: the outgoing breaker should be a 50 A frame device set to trip above 39.7 A, and the run from the alternator terminals to the first panel should be 16 mm2 copper per phase for a normal 20 to 30 m span. On a single-phase set the same current sits on two conductors instead of three, so the cable is heavier for the same kVA, which is the hidden cost of going monophase above about 15 kVA.
The engine behind the badge. SDMO is engine-agnostic by design and picks the diesel per frame. On the T and K ranges in this class that engine is Mitsubishi: the S3L2-SD three-cylinder at 1.32 L on the smaller units and the S4L2-SD four-cylinder at 1.50 L as the rating climbs, both naturally aspirated, mechanically governed and running a 22:1 compression ratio. Mechanical governing is the point: it holds frequency without an electronic map, which is what makes these sets tolerant of dirty fuel and of long periods between runs. The trade is that the fuel curve is fixed, so light-load fuel economy is worse than a common-rail engine of the same output.
Who actually owns SDMO now. Kohler bought SDMO in 2005 and the product has been Kohler-SDMO since; Kohler itself moved to Platinum Equity in 2024. In practice that means the set you buy today is a French-designed package (Brest is the main plant, with assembly also in Spain, India and Brazil) carrying a Kohler controller and a Kohler-owned warranty chain. It also means the K-prefix and T-prefix frames share the same alternator tooling, so a K9 and a T9KM differ mainly in winding and canopy rather than in core hardware.
Emissions. The II suffix marks the engine emission stage. On this frame that is an export-tier build: it is not EPA certified for the United States or Canada and is sold for markets that follow the older Stage IIIA limits. Mechanically it is the simpler machine, with no after-treatment in the exhaust, which is why it is cheaper and why it tolerates long idle periods better than a Tier 4 Final set. If the destination is North America, quote the T4F or T4i version instead.
What the II build actually is. The trailing II on K20U II is the emission stage of the engine. On this platform II is the earlier of the two export calibrations: it targets the Stage II equivalent limits, which were met on engines of this size by combustion optimisation and injection timing rather than by exhaust after-treatment. Practically that means the II build is the most forgiving version of this frame to own. There is no particulate filter, no regeneration strategy and no exhaust back-pressure sensor to fail, so the set runs happily at light load for years without the wet-stacking and glazing that plagues modern low-emission engines on standby duty. Fuel quality tolerance is wider, because the injection equipment is mechanical and the calibration is not chasing a NOx target with a narrow margin. Against that, the II build is the oldest certification of the three and is the first to be shut out of a market when a country tightens its import rules. The IV build of the same frame is the later, cleaner sibling; everything else about the machine is identical.
The alternator end. The machine is a brushless, four-pole, single-bearing alternator direct-coupled to the engine flywheel housing, insulated to class H and protected to IP23. Regulation is by AVR at plus or minus one per cent steady state with total harmonic distortion under three per cent, which is clean enough for a UPS input but not clean enough to skip a filter in front of a sensitive analyser. Single bearing means the alternator has no bearing of its own on the drive end: it relies on the engine flywheel, which is why alignment and flywheel housing condition matter at every overhaul.
Control and protection. The standard panel gives manual and automatic modes, LCD metering of phase voltage, line current, kW, pf, kWh and engine oil pressure, coolant temperature and fuel level, plus a Modbus RTU port on RS485 for a building management system. Protection covers over-speed, low oil pressure, high coolant temperature, over and under voltage, over and under frequency, over-current and phase sequence, with the last twelve events held in a rolling log. That event log is the single most useful diagnostic on the machine: when a set trips at three in the morning, the log tells you which of the eight protections opened first.
Canopy and noise. The open skid build is the machine on a base frame with the radiator exposed, suitable for a plant room or a covered compound. The soundproofed canopy drops the one-metre level to roughly 68 to 72 dB(A) and is the version most export buyers take, because it also weatherproofs the set and lets it stand outdoors. Containerised and trailer-mounted builds use the same core machine with a different envelope, so the electrical data on this page holds across all four.
Fuel and runtime. At full load the engine burns about 6.2 L/h, at 75 per cent about 5.0 L/h and at half load about 4.2 L/h. The litres-per-kWh figure is worst at part load (0.42 L/kWh at half load against 0.31 at full load), which is the counter-intuitive part of sizing: a set run at half load burns more fuel per unit delivered than the same set run hard. On a 50 L base-frame tank that works out to roughly 10 hours at 75 per cent load, and on a 100 L tank roughly double. For anything above eight hours of continuous running, plan a bulk tank with a day tank and a transfer pump rather than relying on the base frame.
Where this rating actually fits. A 20 kW three-phase set is the entry point for light industrial and commercial standby: a workshop with a few machines, a cold store, a small hotel, a telecom site, a water treatment pump set. Three phase at this rating means motors start properly and the cable is a third of the copper of the single-phase equivalent. The constraint is balance: keep the phase-to-phase imbalance under 20 per cent, because an unbalanced load derates the alternator faster than an overload does.
Parallel operation and transfer. Below about 30 kVA, paralleling is rarely worth the control complexity: two sets need load-sharing governors, synchronising hardware and a common switchgear panel, and the cost of that exceeds the cost of simply buying one larger set. What this rating does need is a proper transfer arrangement: a manual changeover switch if the site is attended, an automatic transfer switch with a mains-failure sensor if it is not. The set itself accepts a remote start signal on a two-wire dry contact, which is all an ATS needs.
Maintenance that actually gets done. Oil and oil filter at 250 hours or annually, whichever comes first; fuel filter and air filter at 500 hours; coolant condition checked annually and changed at two years; valve clearance checked at 1,000 hours. The item most often skipped is the load bank test: a set that runs monthly on a light load will wet-stack and glaze the bores, and the first time it sees a real load it will smoke and under-perform. Run it at 75 per cent load for an hour every quarter, and record the exhaust temperature, because that is the number that tells you the engine is healthy.
Sizing it against a guesthouse or small hotel. The load here is domestic rather than industrial: lights, split air conditioners, water heaters, a pump and a kitchen. The trap is diversity. A twelve-room guesthouse might total 18 kW of connected load and never exceed 9 kW at once, because the water heaters cycle and the air conditioners are not all on. A 25 kVA set carries that comfortably once the load is distributed properly, but only if the essential circuits are separated from the non-essential at the changeover. Put the water heaters on the non-essential side and the set will run a guesthouse; leave everything connected and the same set will trip on the first cold morning. The other requirement at this rating is acoustic: the set has to be quiet enough that guests do not ask about it, which means the soundproofed canopy rather than the open skid.
Acoustic treatment beyond the canopy. The soundproofed canopy gets the level down to roughly 68 to 72 dB(A) at one metre, which is fine outdoors and often not fine in a courtyard between buildings. Where the site is enclosed, the canopy is only the first step: orient the radiator discharge away from the nearest facade, put a solid barrier between the set and the boundary rather than an absorbent one, and avoid parallel hard surfaces that set up a standing wave. Do not add extra insulation inside the canopy without checking the cooling air path, because the most common way to overheat a soundproofed set is to make it quieter after it was designed.
Fuel contamination. Diesel stored for months grows bacteria at the water interface, and the resulting sludge blocks filters and corrodes injection equipment. The signs are a filter that clogs repeatedly and a fuel that smells wrong. The prevention is a water-separating pre-filter, a tank that is drained of water at intervals, and a fuel polishing session once a year on any tank above a few hundred litres. On a set this size the injection pump is mechanical and rebuildable, which is a mercy, but a rebuild costs more than a decade of filters.
Open skid or canopy, the first decision. The open skid is the machine on a base frame with the radiator exposed. It is cheaper, easier to service and easier to inspect, and it is the right answer for a plant room or a covered compound where noise is not a boundary issue. The canopy version costs more, adds roughly 68 to 72 dB(A) at one metre of attenuation, and makes the set weatherproof and movable. The decision is almost never about price: it is about whether the set can stand outdoors and whether a neighbour can hear it. Buying the open set and building a room around it later costs more than buying the canopy at the start.
Governor and frequency stability. The engine on this set runs a mechanical governor, which holds frequency within about plus or minus one per cent steady state and recovers from a step load in two to three seconds. That is entirely adequate for motors, lighting, resistive heating and most electronic loads, and it is why the mechanical governor survives in this power class: it has no potentiometers to drift, no speed sensor to fail, and it can be adjusted with a screwdriver. What it does not do is hold frequency tightly enough for a load that changes every few milliseconds. If the site runs variable-speed drives, a UPS with a narrow input window, or medical imaging equipment, the requirement is electronic governing and the specification has to say so at the quotation stage, because it is an engine option rather than an add-on box.
Where it sits in the range. Within the same Kohler-SDMO, K three-phase family at 50 Hz , one step down is the K21H II at 18 kW / 22 kVA, and one step up is the K27 IV at 22 kW / 27 kVA. The step between frames is a different engine displacement and a different alternator core, not a re-rated plate, so the price step is real rather than administrative.
How to order it. Quote five things together and the factory cannot get it wrong: the model (K20U II), the standby and prime rating, the voltage and frequency (400 V, 50 Hz), the phase (three phase), and the enclosure (open skid, soundproofed canopy, containerised or trailer). Add the emission tier if the destination is regulated. Anything else, including the controller variant, the alternator brand and the fuel tank size, is a build option rather than a different machine.
Standby output is 20 kW / 25 kVA (ESP), prime output is 18 kW / 22 kVA (PRP). The standby (ESP) figure is the maximum the set can carry for the duration of a mains failure and is not meant for continuous running. The prime (PRP) figure is what it can hold indefinitely at a varying load. Match the rating to the duty the set will actually see — running a standby-rated machine as prime voids the warranty.
The K20U II is wound for 400 V, 50 Hz, three phase, 4-wire (star), running at 1500 rpm. Voltage and frequency are fixed when the set is built, so confirm the site supply before the order is released. Other voltages and both 50 Hz and 60 Hz builds are available on the same frame.
The K20U II is powered by a Kohler-SDMO diesel engine. Engine and alternator are matched on the test bed, so the set reaches its rating without derating.
Fuel consumption is 6.2 L/h (0.31 L/kWh) at 100% load, 5.0 L/h at 75% load and 4.2 L/h at 50% load. These are measured figures on the standard build at those load points; real consumption shifts with load profile, ambient temperature and fuel quality. Send the expected daily running hours and average load if you want a duty-cycle estimate.
Runtime is 10 hours on a 50 L base tank. Tank capacity can be increased on request, and runtime scales directly with it against the consumption figures above.
Sound pressure is 68-72 dB(A) @ 1 m on the soundproofed build. An open skid set is considerably louder and needs either an acoustic canopy or a separate plant room to meet site noise limits.
The K20U II is available as open skid, weatherproof silent canopy, containerised or mobile trailer. Enclosure choice changes footprint, weight, noise level and price, so specify it with the enquiry and the quotation will match the build.
The K20U II ships with an automatic panel, manual/auto selector, LCD metering, RS485 Modbus and a brushless synchronous, 4-pole, single bearing, direct coupled alternator. Both are build options — alternative controllers and alternator makes can be specified when the order is placed.
On this set, voltage is held by an AVR, +/- 1% steady state, THD < 3% and the machine is built with Class H insulation, IP23 protection. That grade of regulation suits motors, pumps and most electronic loads; for sensitive IT or medical equipment, specify the higher-grade controller option.
The controller trips on over-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence. These shutdowns stop the set before damage occurs, which is what makes an unattended standby installation safe to leave running.
Warranty is 2 years or 2,000 hours, international coverage. It applies to the set as configured — running outside the rated duty, using non-specified fuel or skipping scheduled service will void it.
Send the model (K20U II), the duty (standby or prime), voltage and frequency, phase, and the enclosure type you need. Jinjia Power quotes against a confirmed configuration rather than a list price, so the figure you receive matches the machine that ships. Typical lead time is 20–30 days for units up to 1000 kW and 30–45 days above that.