Model: BCY13-60SPT4
Power: 13KW 13KVA Standby / 13KW 13KVA Prime
Status: Brand New, 2 Years International Warranty
Volume, OEM and project pricing available on request.
| Model | BCY13-60SPT4 |
| Brand | Yanmar |
| Series | BCY series (Yanmar water-cooled diesel) |
| Standby Output | 13 kW / 13 kVA (ESP) |
| Prime Output | 11 kW / 11 kVA (PRP) |
| Power Factor | 1.00 |
| Phase / Connection | Single phase, 2-wire |
| Voltage | 240 V |
| Frequency | 60 Hz |
| Rated Speed | 1800 rpm |
| Current @ Standby | 54.2 A |
| Current @ Prime | 47.5 A |
| Engine | Yanmar diesel, 1800 rpm |
| Fuel Type | Diesel, EN 590 / ASTM D975 grade |
| Fuel Consumption @ 100% | 4.0 L/h (0.31 L/kWh) |
| Fuel Consumption @ 75% | 3.2 L/h |
| Fuel Consumption @ 50% | 2.7 L/h |
| Fuel Tank | Base-frame tank, typically 50-100 L depending on build |
| Runtime @ 75% Load | 15 hours on a 50 L base tank |
| Alternator | Brushless synchronous, 4-pole, single bearing, direct coupled |
| Insulation / Enclosure | Class H insulation, IP23 protection |
| Voltage Regulation | AVR, +/- 1% steady state, THD < 3% |
| Controller | Automatic panel, manual/auto selector, LCD metering, RS485 Modbus |
| Protection | Over-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence |
| Starting System | 12 V DC electric starter, 12 V charge alternator, battery included |
| Cooling | Radiator cooled, 40 C ambient design |
| Dimensions | Open skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation. |
| Dry Weight | Open skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation. |
| Noise Level | Soundproofed version typically 68-72 dB(A) @ 1 m |
| Enclosure Options | Open skid / weatherproof silent canopy / containerised / mobile trailer |
| Emission | Emission tier depends on the destination market and is confirmed per order — EU Stage V, US EPA Tier 4 Final, or unregulated where the market allows. |
| Standard | ISO 8528-1, performance class G1/G2; CE marking supported by the manufacturing plant's Declaration of Conformity |
| Warranty | 2 years or 2,000 hours, international coverage |
| Availability | IN STOCK, Same day shipping Worldwide available |
| Condition | Brand New, 2 Years International Warranty |
| Quality | Load bank tested in our Dongguan facility |
| Reliability | Made in China; factory load-bank tested |
BCY13-60SPT4 at a glance. This is a 13 kW / 13 kVA standby, 11 kW / 11 kVA prime diesel generating set built on a Yanmar platform and wound for 240 V, 60 Hz single phase output at 1800 rpm. It sits in the small stationary class where the set is bought to carry a defined load block rather than to run a plant: a shop, a guesthouse, a telecom cabinet, a small cold store, a farm pump, or the essential circuit of a house. At this rating the physical size matters as much as the numbers, which is why the same machine is offered on an open skid and inside a canopy that fits through a standard doorway.
Reading the model code. BCY13-60SPT4 follows the Yanmar BCY convention: BCY is the water-cooled diesel generator family, the two digits are the kW class, -60 means a 60 Hz build, SP marks the soundproofed single-phase version, T4 marks Tier 4 Final emission hardware and a leading A marks the complete package with AVR and control panel rather than a bare engine. Reading it that way, BCY13-60SPT4 is a 13 kW single phase machine at 60 Hz, Tier 4 Final.
Why kW and kVA are the same number here. On a single-phase set the alternator is wound and rated at unity power factor, so 13 kW and 13 kVA describe the same load and the ratio is 1.00. That is not marketing rounding: it means the machine delivers its full 13 kW into a resistive or lightly inductive load without the alternator being the limit. The moment a motor is hung on it the power factor drops and the usable kW falls below the kVA, so a 13 kVA single-phase set driving a 0.8 pf load gives about 10 kW, not 13. Size single-phase sets on motor starting kVA, never on the kW figure alone.
Standby and prime are two different machines in one frame. ISO 8528 defines standby (ESP) as the maximum a set may deliver for up to 200 hours a year on a varying load, with no overload capability, and prime (PRP) as the continuous rating under a varying load for unlimited hours with a 10 per cent overload window. This set is 13 kW / 13 kVA standby and 11 kW / 11 kVA prime, so the gap between the two, 1.6 kW, is the margin the engine keeps for overload and for altitude and temperature derating. If the load runs for days rather than hours, quote against prime and treat the standby figure as a peak that must not be sustained.
What the nameplate means once it is wired in. At 13 kVA this set pushes 54.2 A down each line on a 240 V single-phase supply, and 47.5 A at the prime rating. Those currents, not the kVA figure, are what the switchgear and the cable have to survive: the outgoing breaker should be an 80 A frame device set to trip above 59.6 A, and the run from the alternator terminals to the first panel should be 25 mm2 copper per phase for a normal 20 to 30 m span. On this single-phase set the current sits on two conductors rather than three, so the cable is heavier than on a three-phase set of the same kVA, which is the hidden cost of going monophase above about 15 kVA.
The engine behind the badge. Yanmar builds the whole package rather than buying an engine in, which is why the BCY sets are unusually compact for their output. The TNV-series water-cooled diesels used in this class are indirect-injection, mechanically governed units built for continuous duty in marine and agricultural service, and the same basic engine is sold into small boats, refrigeration units and construction equipment. The practical benefit is parts: Yanmar's dealer network is denser than any generator brand's in most export markets.
Emissions. The T4i marking means Tier 4 Interim / Stage IIIB hardware, which in this size class is normally an engine-side solution rather than a full DPF package. It is cleaner than the export-tier build but does not carry the same after-treatment service burden, which is why T4i sets are often the practical choice for buyers in markets that accept interim certification.
On the emission marking. This model code carries no trailing emission suffix, which means the set is built to whatever calibration the destination market requires rather than to a fixed stage. In practice that is an advantage at the quotation stage, because the same frame can be ordered as an export-tier build for markets with loose import rules or as a Tier 4 Final build where the rules are tight, without changing the electrical data, the alternator or the canopy. What it does mean is that the engine variant has to be fixed in writing before the order is placed. A set delivered as an export build cannot be upgraded to Tier 4 Final afterwards; the after-treatment is designed into the exhaust and the engine calibration is locked. Confirm the destination country and the certification the buyer needs, then pin the engine variant on the order.
The alternator end. The machine is a brushless, four-pole, single-bearing alternator direct-coupled to the engine flywheel housing, insulated to class H and protected to IP23. Regulation is by AVR at plus or minus one per cent steady state with total harmonic distortion under three per cent, which is clean enough for a UPS input but not clean enough to skip a filter in front of a sensitive analyser. Single bearing means the alternator has no bearing of its own on the drive end: it relies on the engine flywheel, which is why alignment and flywheel housing condition matter at every overhaul.
Control and protection. The standard panel gives manual and automatic modes, LCD metering of phase voltage, line current, kW, pf, kWh and engine oil pressure, coolant temperature and fuel level, plus a Modbus RTU port on RS485 for a building management system. Protection covers over-speed, low oil pressure, high coolant temperature, over and under voltage, over and under frequency, over-current and phase sequence, with the last twelve events held in a rolling log. That event log is the single most useful diagnostic on the machine: when a set trips at three in the morning, the log tells you which of the eight protections opened first.
Canopy and noise. The open skid version is the bare machine on a steel base frame with the radiator exposed; it is the cheapest and the easiest to service but it is loud enough that it cannot sit next to a neighbour's fence. The soundproofed canopy version adds a lined enclosure with a residential-grade silencer and takes the level at one metre down to roughly 68 to 72 dB(A), which is normal conversation at arm's length. For a single-phase set sitting beside a house, the canopy is not optional: the extra cost buys the planning permission.
Fuel and runtime. At full load the engine burns about 4.0 L/h, at 75 per cent about 3.2 L/h and at half load about 2.7 L/h. The litres-per-kWh figure is worst at part load (0.42 L/kWh at half load against 0.31 at full load), which is the counter-intuitive part of sizing: a set run at half load burns more fuel per unit delivered than the same set run hard. On a 50 L base-frame tank that works out to roughly 15 hours at 75 per cent load, and on a 100 L tank roughly double. For anything above eight hours of continuous running, plan a bulk tank with a day tank and a transfer pump rather than relying on the base frame.
Where this rating actually fits. A 13 kW single-phase set is the standard answer for a house, a small guesthouse, a shop, a clinic or a farm where the load is lights, fridges, air conditioning, a pump and a handful of tools. The limit is motor starting: a 2.2 kW borehole pump pulls five to six times its running current for a second, and a 13 kVA set will take that only if nothing else is on line at the same moment. Sequence the loads, or fit a soft starter, and the set behaves; put everything on at once and it stalls.
Parallel operation and transfer. Below about 30 kVA, paralleling is rarely worth the control complexity: two sets need load-sharing governors, synchronising hardware and a common switchgear panel, and the cost of that exceeds the cost of simply buying one larger set. What this rating does need is a proper transfer arrangement: a manual changeover switch if the site is attended, an automatic transfer switch with a mains-failure sensor if it is not. The set itself accepts a remote start signal on a two-wire dry contact, which is all an ATS needs.
Maintenance that actually gets done. Oil and oil filter at 250 hours or annually, whichever comes first; fuel filter and air filter at 500 hours; coolant condition checked annually and changed at two years; valve clearance checked at 1,000 hours. The item most often skipped is the load bank test: a set that runs monthly on a light load will wet-stack and glaze the bores, and the first time it sees a real load it will smoke and under-perform. Run it at 75 per cent load for an hour every quarter, and record the exhaust temperature, because that is the number that tells you the engine is healthy.
Sizing it against irrigation and farm use. Farm loads are seasonal and brutal: a borehole pump starting against a full head of water is close to a locked-rotor condition for the first moment, and it is often the only load on the set, which means there is no other load to stabilise the frequency. A 13 kVA set will start a pump of roughly a quarter to a third of its kVA if the pump has a soft starter or a star-delta arrangement, and considerably less if it is direct-on-line. The other farm consideration is fuel: a set that runs eight hours a day through the dry season needs a bulk tank and a water trap, because farm diesel is stored in conditions that put water and dirt into the injection system. Fit a pre-filter with a water separator and drain it weekly.
Earthing and neutral arrangement. The alternator on this set is a single-phase, two-wire machine, so the neutral is available and the earthing arrangement is a decision, not a default. For a set operating as a standby source with a changeover that switches the neutral, the set neutral is bonded to earth at the set and the installation is treated as a separately derived system. For a set operating in parallel with the mains, or through a changeover that does not switch the neutral, the bonding has to follow the installation's existing arrangement or the residual current protection will not work. This is the item to get a competent electrician to confirm in writing, because getting it wrong is a shock hazard rather than an inconvenience.
AVR drift and voltage instability. When the voltage wanders or the lights flicker, the automatic voltage regulator is the first suspect, but it is usually the last cause. Check the connections and the sensing leads first, then the exciter diode pack, then the AVR itself. A failing diode produces a characteristic symptom: voltage that is fine on load and drops sharply when the load is removed. An AVR that has genuinely failed usually fails outright rather than drifting. Keep a spare AVR on site for a critical installation; it is a small part with a long lead time and it stops the whole machine.
What the warranty should actually cover. A two-year international warranty is only worth what the local support is worth. Before ordering, confirm three things: who performs warranty work in the destination country, whether the warranty covers parts only or parts and labour, and what the response time is. A warranty that requires the failed part to be shipped back to the factory before a replacement is issued is a warranty that costs the customer a month of downtime. The other clause to read is the exclusion for ''misuse'', which some warranties interpret to include running below the recommended load, so check that a light-load application does not void coverage.
Starting and cold start. The set starts on a 12 V electric starter drawing from a battery that is charged by a small engine-driven alternator. At temperatures above freezing that is unremarkable. Below about five degrees the compression-ignition engine needs help, and the help on this class of engine is a set of glow plugs or an air inlet heater, operated automatically by the controller with a short pre-heat before cranking. Two practical points follow. First, the battery is the weak link in cold weather, so a battery that is four years old will start the set in summer and fail in winter. Second, the pre-heat circuit draws current from the same battery, so a marginal battery plus a cold morning is a no-start. A mains float charger solves both.
Where it sits in the range. Within the same Yanmar family at 60 Hz, one step up is the BCY18-60SP at 18 kW / 18 kVA. The step between frames is a different engine displacement and a different alternator core, not a re-rated plate, so the price step is real rather than administrative.
How to order it. Quote five things together and the factory cannot get it wrong: the model (BCY13-60SPT4), the standby and prime rating, the voltage and frequency (240 V, 60 Hz), the phase (single phase), and the enclosure (open skid, soundproofed canopy, containerised or trailer). Add the emission tier if the destination is regulated. Anything else, including the controller variant, the alternator brand and the fuel tank size, is a build option rather than a different machine.
Standby output is 13 kW / 13 kVA (ESP), prime output is 11 kW / 11 kVA (PRP). The standby (ESP) figure is the maximum the set can carry for the duration of a mains failure and is not meant for continuous running. The prime (PRP) figure is what it can hold indefinitely at a varying load. Match the rating to the duty the set will actually see — running a standby-rated machine as prime voids the warranty.
The BCY13-60SPT4 is wound for 240 V, 60 Hz, single phase, 2-wire, running at 1800 rpm. Voltage and frequency are fixed when the set is built, so confirm the site supply before the order is released. Other voltages and both 50 Hz and 60 Hz builds are available on the same frame.
The BCY13-60SPT4 is powered by a Yanmar diesel engine. Engine and alternator are matched on the test bed, so the set reaches its rating without derating.
Fuel consumption is 4.0 L/h (0.31 L/kWh) at 100% load, 3.2 L/h at 75% load and 2.7 L/h at 50% load. These are measured figures on the standard build at those load points; real consumption shifts with load profile, ambient temperature and fuel quality. Send the expected daily running hours and average load if you want a duty-cycle estimate.
Runtime is 15 hours on a 50 L base tank. Tank capacity can be increased on request, and runtime scales directly with it against the consumption figures above.
Sound pressure is 68-72 dB(A) @ 1 m on the soundproofed build. An open skid set is considerably louder and needs either an acoustic canopy or a separate plant room to meet site noise limits.
The BCY13-60SPT4 is available as open skid, weatherproof silent canopy, containerised or mobile trailer. Enclosure choice changes footprint, weight, noise level and price, so specify it with the enquiry and the quotation will match the build.
The BCY13-60SPT4 ships with an automatic panel, manual/auto selector, LCD metering, RS485 Modbus and a brushless synchronous, 4-pole, single bearing, direct coupled alternator. Both are build options — alternative controllers and alternator makes can be specified when the order is placed.
On this set, voltage is held by an AVR, +/- 1% steady state, THD < 3% and the machine is built with Class H insulation, IP23 protection. That grade of regulation suits motors, pumps and most electronic loads; for sensitive IT or medical equipment, specify the higher-grade controller option.
The controller trips on over-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence. These shutdowns stop the set before damage occurs, which is what makes an unattended standby installation safe to leave running.
Warranty is 2 years or 2,000 hours, international coverage. It applies to the set as configured — running outside the rated duty, using non-specified fuel or skipping scheduled service will void it.
Send the model (BCY13-60SPT4), the duty (standby or prime), voltage and frequency, phase, and the enclosure type you need. Jinjia Power quotes against a confirmed configuration rather than a list price, so the figure you receive matches the machine that ships. Typical lead time is 20–30 days for units up to 1000 kW and 30–45 days above that.