Model: T16UM II
Power: 15KW 15KVA Standby / 14KW 14KVA Prime
Status: Brand New, 2 Years International Warranty
Volume, OEM and project pricing available on request.
| Model | T16UM II |
| Brand | SDMO |
| Series | T series (stationary, compact) |
| Standby Output | 15 kW / 15 kVA (ESP) |
| Prime Output | 13 kW / 13 kVA (PRP) |
| Power Factor | 1.00 |
| Phase / Connection | Single phase, 2-wire |
| Voltage | 230 V |
| Frequency | 50 Hz |
| Rated Speed | 1500 rpm |
| Current @ Standby | 65.2 A |
| Current @ Prime | 57.4 A |
| Engine | Kohler-SDMO diesel, 1500 rpm |
| Fuel Type | Diesel, EN 590 / ASTM D975 grade |
| Fuel Consumption @ 100% | 4.7 L/h (0.31 L/kWh) |
| Fuel Consumption @ 75% | 3.7 L/h |
| Fuel Consumption @ 50% | 3.1 L/h |
| Fuel Tank | Base-frame tank, typically 50-100 L depending on build |
| Runtime @ 75% Load | 13 hours on a 50 L base tank |
| Alternator | Brushless synchronous, 4-pole, single bearing, direct coupled |
| Insulation / Enclosure | Class H insulation, IP23 protection |
| Voltage Regulation | AVR, +/- 1% steady state, THD < 3% |
| Controller | Automatic panel, manual/auto selector, LCD metering, RS485 Modbus |
| Protection | Over-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence |
| Starting System | 12 V DC electric starter, 12 V charge alternator, battery included |
| Cooling | Radiator cooled, 40 C ambient design |
| Dimensions | Open skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation. |
| Dry Weight | Open skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation. |
| Noise Level | Soundproofed version typically 68-72 dB(A) @ 1 m |
| Enclosure Options | Open skid / weatherproof silent canopy / containerised / mobile trailer |
| Emission | Emission tier depends on the destination market and is confirmed per order — EU Stage V, US EPA Tier 4 Final, or unregulated where the market allows. |
| Standard | ISO 8528-1, performance class G1/G2; CE marking supported by the manufacturing plant's Declaration of Conformity |
| Warranty | 2 years or 2,000 hours, international coverage |
| Availability | IN STOCK, Same day shipping Worldwide available |
| Condition | Brand New, 2 Years International Warranty |
| Quality | Load bank tested in our Dongguan facility |
| Reliability | Made in China; factory load-bank tested |
T16UM II at a glance. This is a 15 kW / 15 kVA standby, 13 kW / 13 kVA prime diesel generating set built on a Kohler-SDMO platform and wound for 230 V, 50 Hz single phase output at 1500 rpm. It sits in the small stationary class where the set is bought to carry a defined load block rather than to run a plant: a shop, a guesthouse, a telecom cabinet, a small cold store, a farm pump, or the essential circuit of a house. At this rating the physical size matters as much as the numbers, which is why the same machine is offered on an open skid and inside a canopy that fits through a standard doorway.
Reading the model code. T16UM II decodes as the T prefix, the frame number 16 which tracks the kVA class, and the suffix string UM. The T range uses Mitsubishi heavy-duty industrial diesels (S3L2-SD on the three-cylinder units, S4L2-SD on the four-cylinder units), chosen for mechanical governing and a 22:1 compression ratio that keeps cold-start behaviour predictable. In this case the M suffix marks the monophase build; the U marks the uprated frame, which is why the same number appears with a higher kVA in the U version; the trailing II is the emission stage of the engine fitted, not a different alternator. The frame number is a direct read of the rating: 16 in the code, 15 kVA on the plate, so the label and the data agree.
Why kW and kVA are the same number here. On a single-phase set the alternator is wound and rated at unity power factor, so 15 kW and 15 kVA describe the same load and the ratio is 1.00. That is not marketing rounding: it means the machine delivers its full 15 kW into a resistive or lightly inductive load without the alternator being the limit. The moment a motor is hung on it the power factor drops and the usable kW falls below the kVA, so a 15 kVA single-phase set driving a 0.8 pf load gives about 12 kW, not 15. Size single-phase sets on motor starting kVA, never on the kW figure alone.
Standby and prime are two different machines in one frame. ISO 8528 defines standby (ESP) as the maximum a set may deliver for up to 200 hours a year on a varying load, with no overload capability, and prime (PRP) as the continuous rating under a varying load for unlimited hours with a 10 per cent overload window. This set is 15 kW / 15 kVA standby and 13 kW / 13 kVA prime, so the gap between the two, 1.8 kW, is the margin the engine keeps for overload and for altitude and temperature derating. If the load runs for days rather than hours, quote against prime and treat the standby figure as a peak that must not be sustained.
What the nameplate means once it is wired in. At 15 kVA this set pushes 65.2 A down each line on a 230 V single-phase supply, and 57.4 A at the prime rating. Those currents, not the kVA figure, are what the switchgear and the cable have to survive: the outgoing breaker should be a 100 A frame device set to trip above 71.7 A, and the run from the alternator terminals to the first panel should be 25 mm2 copper per phase for a normal 20 to 30 m span. On a single-phase set the same current sits on two conductors instead of three, so the cable is heavier for the same kVA, which is the hidden cost of going monophase above about 15 kVA.
The engine behind the badge. SDMO is engine-agnostic by design and picks the diesel per frame. On the T and K ranges in this class that engine is Mitsubishi: the S3L2-SD three-cylinder at 1.32 L on the smaller units and the S4L2-SD four-cylinder at 1.50 L as the rating climbs, both naturally aspirated, mechanically governed and running a 22:1 compression ratio. Mechanical governing is the point: it holds frequency without an electronic map, which is what makes these sets tolerant of dirty fuel and of long periods between runs. The trade is that the fuel curve is fixed, so light-load fuel economy is worse than a common-rail engine of the same output.
Who actually owns SDMO now. Kohler bought SDMO in 2005 and the product has been Kohler-SDMO since; Kohler itself moved to Platinum Equity in 2024. In practice that means the set you buy today is a French-designed package (Brest is the main plant, with assembly also in Spain, India and Brazil) carrying a Kohler controller and a Kohler-owned warranty chain. It also means the K-prefix and T-prefix frames share the same alternator tooling, so a K9 and a T9KM differ mainly in winding and canopy rather than in core hardware.
Emissions. The II suffix marks the engine emission stage. On this frame that is an export-tier build: it is not EPA certified for the United States or Canada and is sold for markets that follow the older Stage IIIA limits. Mechanically it is the simpler machine, with no after-treatment in the exhaust, which is why it is cheaper and why it tolerates long idle periods better than a Tier 4 Final set. If the destination is North America, quote the T4F or T4i version instead.
What the II build actually is. The trailing II on T16UM II is the emission stage of the engine. On this platform II is the earlier of the two export calibrations: it targets the Stage II equivalent limits, which were met on engines of this size by combustion optimisation and injection timing rather than by exhaust after-treatment. Practically that means the II build is the most forgiving version of this frame to own. There is no particulate filter, no regeneration strategy and no exhaust back-pressure sensor to fail, so the set runs happily at light load for years without the wet-stacking and glazing that plagues modern low-emission engines on standby duty. Fuel quality tolerance is wider, because the injection equipment is mechanical and the calibration is not chasing a NOx target with a narrow margin. Against that, the II build is the oldest certification of the three and is the first to be shut out of a market when a country tightens its import rules. The IV build of the same frame is the later, cleaner sibling; everything else about the machine is identical.
The alternator end. The machine is a brushless, four-pole, single-bearing alternator direct-coupled to the engine flywheel housing, insulated to class H and protected to IP23. Regulation is by AVR at plus or minus one per cent steady state with total harmonic distortion under three per cent, which is clean enough for a UPS input but not clean enough to skip a filter in front of a sensitive analyser. Single bearing means the alternator has no bearing of its own on the drive end: it relies on the engine flywheel, which is why alignment and flywheel housing condition matter at every overhaul.
Control and protection. The standard panel gives manual and automatic modes, LCD metering of phase voltage, line current, kW, pf, kWh and engine oil pressure, coolant temperature and fuel level, plus a Modbus RTU port on RS485 for a building management system. Protection covers over-speed, low oil pressure, high coolant temperature, over and under voltage, over and under frequency, over-current and phase sequence, with the last twelve events held in a rolling log. That event log is the single most useful diagnostic on the machine: when a set trips at three in the morning, the log tells you which of the eight protections opened first.
Canopy and noise. The open skid version is the bare machine on a steel base frame with the radiator exposed; it is the cheapest and the easiest to service but it is loud enough that it cannot sit next to a neighbour's fence. The soundproofed canopy version adds a lined enclosure with a residential-grade silencer and takes the level at one metre down to roughly 68 to 72 dB(A), which is normal conversation at arm's length. For a single-phase set sitting beside a house, the canopy is not optional: the extra cost buys the planning permission.
Fuel and runtime. At full load the engine burns about 4.7 L/h, at 75 per cent about 3.7 L/h and at half load about 3.1 L/h. The litres-per-kWh figure is worst at part load (0.42 L/kWh at half load against 0.31 at full load), which is the counter-intuitive part of sizing: a set run at half load burns more fuel per unit delivered than the same set run hard. On a 50 L base-frame tank that works out to roughly 13 hours at 75 per cent load, and on a 100 L tank roughly double. For anything above eight hours of continuous running, plan a bulk tank with a day tank and a transfer pump rather than relying on the base frame.
Where this rating actually fits. A 15 kW single-phase set is the standard answer for a house, a small guesthouse, a shop, a clinic or a farm where the load is lights, fridges, air conditioning, a pump and a handful of tools. The limit is motor starting: a 2.2 kW borehole pump pulls five to six times its running current for a second, and a 15 kVA set will take that only if nothing else is on line at the same moment. Sequence the loads, or fit a soft starter, and the set behaves; put everything on at once and it stalls.
Parallel operation and transfer. Below about 30 kVA, paralleling is rarely worth the control complexity: two sets need load-sharing governors, synchronising hardware and a common switchgear panel, and the cost of that exceeds the cost of simply buying one larger set. What this rating does need is a proper transfer arrangement: a manual changeover switch if the site is attended, an automatic transfer switch with a mains-failure sensor if it is not. The set itself accepts a remote start signal on a two-wire dry contact, which is all an ATS needs.
Maintenance that actually gets done. Oil and oil filter at 250 hours or annually, whichever comes first; fuel filter and air filter at 500 hours; coolant condition checked annually and changed at two years; valve clearance checked at 1,000 hours. The item most often skipped is the load bank test: a set that runs monthly on a light load will wet-stack and glaze the bores, and the first time it sees a real load it will smoke and under-perform. Run it at 75 per cent load for an hour every quarter, and record the exhaust temperature, because that is the number that tells you the engine is healthy.
Sizing it against a guesthouse or small hotel. The load here is domestic rather than industrial: lights, split air conditioners, water heaters, a pump and a kitchen. The trap is diversity. A twelve-room guesthouse might total 18 kW of connected load and never exceed 9 kW at once, because the water heaters cycle and the air conditioners are not all on. A 15 kVA set carries that comfortably once the load is distributed properly, but only if the essential circuits are separated from the non-essential at the changeover. Put the water heaters on the non-essential side and the set will run a guesthouse; leave everything connected and the same set will trip on the first cold morning. The other requirement at this rating is acoustic: the set has to be quiet enough that guests do not ask about it, which means the soundproofed canopy rather than the open skid.
Earthing and neutral arrangement. The alternator on this set is a four-wire star machine, so the neutral is available and the earthing arrangement is a decision, not a default. For a set operating as a standby source with a changeover that switches the neutral, the set neutral is bonded to earth at the set and the installation is treated as a separately derived system. For a set operating in parallel with the mains, or through a changeover that does not switch the neutral, the bonding has to follow the installation's existing arrangement or the residual current protection will not work. This is the item to get a competent electrician to confirm in writing, because getting it wrong is a shock hazard rather than an inconvenience.
Wet stacking, the number one killer of standby sets. A diesel that runs repeatedly below about thirty per cent load never reaches combustion temperature, so the bores glaze, the exhaust ports coke up and unburnt fuel dilutes the lube oil. The symptoms are a set that smokes blue under load, uses oil, and produces less than its rating. It is entirely a duty problem rather than a manufacturing one, and it is the reason a 15 kVA set installed on a 4 kW load will be scrap in five years while the same set run at 70 per cent lasts twenty. The fix costs nothing: a load bank session, or a dummy load, for an hour a quarter at three-quarters of the rating. If the site cannot provide that load, buy a smaller set.
Open skid or canopy, the first decision. The open skid is the machine on a base frame with the radiator exposed. It is cheaper, easier to service and easier to inspect, and it is the right answer for a plant room or a covered compound where noise is not a boundary issue. The canopy version costs more, adds roughly 68 to 72 dB(A) at one metre of attenuation, and makes the set weatherproof and movable. The decision is almost never about price: it is about whether the set can stand outdoors and whether a neighbour can hear it. Buying the open set and building a room around it later costs more than buying the canopy at the start.
Noise and vibration, measured rather than claimed. Sound level on a canopy set is quoted at one metre and at seven metres, and the two numbers differ because sound falls off with distance: roughly 68 to 72 dB(A) at one metre becomes about 58 dB(A) at seven. What the datasheet does not tell you is the tonality, and a set with a pronounced low-frequency component is more annoying at a boundary than a louder but smoother one. Vibration is a separate issue and it is measured in millimetres per second at the alternator bearing housing; anything above about seven is worth investigating, and the usual cause is a collapsed anti-vibration mount or a misaligned coupling. Ask for both numbers at commissioning and record them, so that a change two years later has a baseline.
Where it sits in the range. Within the same Kohler-SDMO, T monophase family at 50 Hz , one step down is the T8UM II at 8 kW / 8 kVA, and one step up is the T17KM IV at 17 kW / 17 kVA. The step between frames is a different engine displacement and a different alternator core, not a re-rated plate, so the price step is real rather than administrative.
How to order it. Quote five things together and the factory cannot get it wrong: the model (T16UM II), the standby and prime rating, the voltage and frequency (230 V, 50 Hz), the phase (single phase), and the enclosure (open skid, soundproofed canopy, containerised or trailer). Add the emission tier if the destination is regulated. Anything else, including the controller variant, the alternator brand and the fuel tank size, is a build option rather than a different machine.
Standby output is 15 kW / 15 kVA (ESP), prime output is 13 kW / 13 kVA (PRP). The standby (ESP) figure is the maximum the set can carry for the duration of a mains failure and is not meant for continuous running. The prime (PRP) figure is what it can hold indefinitely at a varying load. Match the rating to the duty the set will actually see — running a standby-rated machine as prime voids the warranty.
The T16UM II is wound for 230 V, 50 Hz, single phase, 2-wire, running at 1500 rpm. Voltage and frequency are fixed when the set is built, so confirm the site supply before the order is released. Other voltages and both 50 Hz and 60 Hz builds are available on the same frame.
The T16UM II is powered by a Kohler-SDMO diesel engine. Engine and alternator are matched on the test bed, so the set reaches its rating without derating.
Fuel consumption is 4.7 L/h (0.31 L/kWh) at 100% load, 3.7 L/h at 75% load and 3.1 L/h at 50% load. These are measured figures on the standard build at those load points; real consumption shifts with load profile, ambient temperature and fuel quality. Send the expected daily running hours and average load if you want a duty-cycle estimate.
Runtime is 13 hours on a 50 L base tank. Tank capacity can be increased on request, and runtime scales directly with it against the consumption figures above.
Sound pressure is 68-72 dB(A) @ 1 m on the soundproofed build. An open skid set is considerably louder and needs either an acoustic canopy or a separate plant room to meet site noise limits.
The T16UM II is available as open skid, weatherproof silent canopy, containerised or mobile trailer. Enclosure choice changes footprint, weight, noise level and price, so specify it with the enquiry and the quotation will match the build.
The T16UM II ships with an automatic panel, manual/auto selector, LCD metering, RS485 Modbus and a brushless synchronous, 4-pole, single bearing, direct coupled alternator. Both are build options — alternative controllers and alternator makes can be specified when the order is placed.
On this set, voltage is held by an AVR, +/- 1% steady state, THD < 3% and the machine is built with Class H insulation, IP23 protection. That grade of regulation suits motors, pumps and most electronic loads; for sensitive IT or medical equipment, specify the higher-grade controller option.
The controller trips on over-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence. These shutdowns stop the set before damage occurs, which is what makes an unattended standby installation safe to leave running.
Warranty is 2 years or 2,000 hours, international coverage. It applies to the set as configured — running outside the rated duty, using non-specified fuel or skipping scheduled service will void it.
Send the model (T16UM II), the duty (standby or prime), voltage and frequency, phase, and the enclosure type you need. Jinjia Power quotes against a confirmed configuration rather than a list price, so the figure you receive matches the machine that ships. Typical lead time is 20–30 days for units up to 1000 kW and 30–45 days above that.