86-0769-89610677 / 86-13553838770 | info@jinjiadongli.com
Home > AC ALTERNATORS > 282PSL1716 1-Phase - Marathon | 25 kW
282PSL1716 1-Phase Marathon 25 kW 31.2 kVA Single phase AC alternator | Jinjia Power

282PSL1716 1-Phase - Marathon | 25 kW

282PSL1716-1-PHASE

Status: IN STOCK, Same day shipping Worldwide available | New

Volume, OEM and project pricing available on request.

πŸ“ž Get a Quote:86-13553838770
← Back to products

Specifications

SKU282PSL1716 1-Phase
BrandMarathon
SeriesMarathon PSL
Frame282
Core length1716
PhaseSingle phase
Poles4-pole
Rated power25 kW
Apparent power31.2 kVA at 0.8 PF
Rated voltage240 V
Rated current130.2 A
Frequency60 Hz
Power factor0.8
Rated speed1800 rpm
Insulation classNEMA Class H
Ingress protectionIP22 / IP23
Excitation systemself-excited brushless with SE350E AVR
Voltage regulatorSE350E standard / PM500 / DVR2400 with PMG
Voltage regulation+/-1.0%
Bearingsealed for life ball bearings
Winding connection12 re-connectable
Maximum overspeed2250 rpm
Outline dimensionsA 14.00 in | B 7.00 | BA 6.56 | C 18.50 (C w/PMG 23.10) | D 13.64 | E 6.25 | 2F 5.00 | H 8.00 | P 13.55 | X 18.56 | Y 8.93 | Z 3.42
Frequency60 Hz
Rated speed1800 rpm
Core stack position6 of 6 in PSL family
Adjacent ratings282PSL1705 3-Phase at 20 kW / 283PSL1717 1-Phase at 30 kW
Altitude1000 m
StandardsNEMA MG1-32, UL 1004, CSA C22.2 No.100, IEC 60034
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 3 Years International Warranty

Product Overview

Model. The 282PSL1716 1-Phase is a Marathon PSL 4-pole alternator. Marathon reads the model as frame 282 followed by the PSL family code and the winding number 1716. The frame sets the mechanical envelope and the family code sets whether the machine is wound for single-phase or three-phase service. It is wound for single-phase service at 60 Hz. Electrical rating. At 0.8 power factor lagging this machine is rated 25 kW, which is 31.2 kVA, delivered as single-phase at 240 V 60 Hz. At 240 V that is 130.2 A through the line and the neutral. Small frames like this are sensitive to load power factor: running them well below 0.8 PF pushes the field current up and the stator current up at the same kW, so the nameplate kVA is the number to design to. The 1800 rpm figure is synchronous speed, so there is no slip and no speed-dependent voltage droop. Frame and core. The 282 frame carries the 1716 core. Frame size fixes the stator bore and the shaft centre height; the core length fixes how much active iron sits in that bore, and therefore how much output the machine can make at a given temperature rise. The exact finished weight and outline drawing depend on the winding and the coupling, so they are confirmed on the certified datasheet issued with the order. Outline dimensions in inches: A 14.00 in | B 7.00 | BA 6.56 | C 18.50 (C w/PMG 23.10) | D 13.64 | E 6.25 | 2F 5.00 | H 8.00 | P 13.55 | X 18.56 | Y 8.93 | Z 3.42. The cooling circuit is direct air cooled, IC01, and the frame is rolled steel frame, cast iron end brackets. Single-phase winding. This is a single-phase machine, so the winding is laid out to produce one sinusoid across the output terminals rather than a three-phase set. Single-phase alternators of this size are almost always fitted with a capacitor or a compounded excitation arrangement to hold the voltage steady as the load swings, because the pulsating armature reaction of a single-phase load pulls the terminal voltage around far more than a balanced three-phase load does. The practical consequence for the buyer is that single-phase kVA and three-phase kVA of the same frame are not interchangeable: the single-phase machine is derated for the same iron, and the wiring, the circuit breaker and the cable all have to be sized on the single-phase current, which is roughly 1.7 times the three-phase current for the same kVA at the same voltage. Four-pole build. A four-pole machine turns at 1500 rpm on 50 Hz and 1800 rpm on 60 Hz. That is the standard choice for generator sets from a few tens of kVA up to the low megawatt range, because the lower rotor speed gives a longer bearing life, a quieter fan, a higher subtransient reactance that is easier to coordinate with downstream protection, and a rotor that can carry a substantial damper cage for parallel operation. The trade is weight: a four-pole machine of a given kVA is roughly twice the mass of a two-pole one. Excitation and voltage regulation. The excitation system is self-excited brushless with SE350E AVR, regulated by SE350E standard / PM500 / DVR2400 with PMG, holding steady-state voltage to +/-1.0%. Marathon fits the SE350E as the standard regulator on the smaller frames, with the PM500 and the DVR2400 available where a PMG is specified. On the Mariner and harsh-duty builds the excitation stator is fully encapsulated and the rotating rectifier is a heavy-duty assembly with a 300% diode margin and sealed welded stud terminations, which is the difference between a machine that survives a damp boat hold and one that does not. Mechanical build. The frame is rolled steel frame, cast iron end brackets. Bearings are sealed for life ball bearings. Mounting is single bearing SAE flange or two bearing. Maximum overspeed is 2250 rpm, and the machine is rated for 1000 m. On the 280 to 430 frames the machine ships with twelve leads and a link board as standard, and the minimum inlet clearance is six inches. On the 570 frame and above the terminal box is mounted on top with the link board inside it, and a selenium surge suppressor is fitted as standard from the 360 frame up. Harsh-duty builds get multiple dip-and-bake cycles on the main stator. Where it fits. Light commercial duty: a retail unit, a small workshop, a guesthouse, or a farm with an irrigation pump. Loads are mostly resistive and lightly inductive, so a standard shunt-excited machine copes without a PMG. On a single-phase machine of 25 kW the practical constraint is usually the downstream protection and the cable, not the alternator itself. Core stack position. The 1716 core is stack position 6 of 6 in the PSL family, roughly 100% of the way along the family's lamination length range. It is the longest stack the PSL family is built with. Long-stack builds carry the rating in the frame with the lowest flux density of the family. The extra iron costs length and weight, and buys a cooler-running core, lower magnetising current, better part-load efficiency and more margin for site ambient above 40 C or for a non-standard voltage. Where it sits in the range. The PSL family is catalogued from 12 kW up to 225 kW, and this page covers the 25 kW / 31.2 kVA point. The step below it is the 282PSL1705 3-Phase at 20 kW, 25 kVA. The step above it is the 283PSL1717 1-Phase at 30 kW, 37.5 kVA. If your load sits between two steps, take the higher one and let the engine run at part load rather than pushing the smaller machine to its limit on a hot afternoon. Reading the model code. A Marathon designation is read as the frame number, the winding family (PSL, CSL, CSA, RSL, FSL or FDL), and a four-digit winding code. Here that gives 282PSL1716 1-Phase for the model, 282 for the frame, 1716 for the core and single for the phase count, so the code on the nameplate and the code on this page match one for one. Quoting the full code rather than just the frame matters on this family, because the same frame number is built in several core lengths and the winding changes with the voltage. Frame position. The PSL range is built on 9 frame sizes β€” 281, 282, 283, 284, 285, 286, 287, 431, 432 β€” and the 282 frame is number 2 of them. No other frame in this range carries exactly this rating, so the 282 is the only build at 25 kW and there is no cross-frame decision to make. What the nameplate means once it is wired in. At 25 kW and 31.2 kVA this machine pushes 130 A down each line on a 240 V single-phase supply. That current, not the kVA figure, is what the switchgear and the cable have to survive, so the outgoing breaker should be a 250 A frame device set to trip above 163 A, and the run from the alternator terminals to the first panel should be 50 mm2 copper per phase for a normal 25 to 30 m span. Longer runs, aluminium conductors or tray-installed cable all move that number up, and the volt drop at full load is what decides it in the end. On the mechanical side the prime mover has to deliver about 28 kW at the coupling. The usual 1.10 to 1.15 margin over the alternator rating covers the fan, the excitation loss and the governor droop, and it is the reason a 25 kW alternator is normally quoted against a 28 kW engine rather than a 25 kW one. Fuel burn follows the electrical load almost linearly in this range. At a realistic 0.29 L per kWh for a modern common-rail set, running this alternator at full rating takes roughly 7 L per hour; at 75 per cent load it drops to about 6 L per hour and at half load to about 4 L per hour, because the fixed losses stay put while the variable ones fall away. Quote the breaker frame, the cable size and the engine rating together with the alternator, because a set that is right on paper and undersized on the cable is the most common way a good alternator gets blamed for a bad installation. Where this rating sits in the frame ladder. Within the 282 frame PSL carries 4 distinct ratings, and this is number 4 of them at 25 kW. This is the largest rating the 282 frame carries; the step below is the 282PSL1715 1-Phase at 20 kW / 25 kVA, 5 kW under this one. Anything bigger moves to the next frame size up. Every step inside one frame is one more lamination stack length. The shaft, the bearings, the foot pattern, the terminal box and the AVR are the same part across the whole ladder, and only the core length and the winding change. That is why the price gap between two neighbouring steps is small while the gap between the last step of one frame and the first step of the next is large. It also sets the value-engineering rule: dropping one core size inside the frame saves money and axial length but eats the margin to the load, while stepping up one size costs far less than jumping to the next frame and buying a bigger skid, a bigger breaker and a bigger cable with it. Supply. Supplied as a genuine Marathon unit β€” Regal Rexnord, built in United States. Marathon alternators are built by Regal Rexnord in the United States. Each alternator ships with the routine test certificate, the winding connection diagram, and the AVR commissioning sheet. Export packing is seaworthy plywood on a pallet sized to the frame, and the machine is strapped and shrink-wrapped inside it. Tell us the engine make and model, the coupling arrangement (single or two bearing), the voltage and frequency, and whether you need a PMG, and we will confirm the build before it leaves the works.

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com

Jinjia Power, Quality Assured

Frequently Asked Questions

What is the rated output of the 282PSL1716 1-Phase alternator?

The 282PSL1716 1-Phase is rated at 25 kW (31.2 kVA at 0.8 PF). The kW figure is the mechanical shaft input it accepts; the kVA figure is the electrical output at the stated power factor. Size the engine against the kW figure with a margin for the alternator's efficiency, and size the load against the kVA figure.

What voltage and frequency does the 282PSL1716 1-Phase produce?

Rated output is 240 V at 60 Hz, Single phase. The winding is 12 re-connectable. Check the winding connection before ordering if your site runs a different voltage β€” a reconnectable unit can be rewired, a fixed-winding unit cannot.

What is the rated current of the 282PSL1716 1-Phase?

Rated current is 130.2 A at 240 V, Single phase. Use this figure when sizing cables, circuit breakers and the transfer switch β€” the breaker is set against the alternator's rated current, not the engine's.

How fast does the 282PSL1716 1-Phase run and how many poles does it have?

It is a 4-pole machine running at 1800 rpm, 60 Hz. Pole count and speed are linked: a 4-pole machine at 50 Hz turns at 1500 rpm and at 60 Hz at 1800 rpm. The speed is fixed by the frequency, so the same frame cannot be run at an arbitrary speed.

What insulation class and ingress protection does the 282PSL1716 1-Phase have?

Insulation is NEMA Class H and the enclosure is rated IP22 / IP23. Maximum overspeed is 2250 rpm. Class H insulation is rated for a 180 Β°C rise limit and gives margin for hot plant rooms; the IP rating states what the enclosure keeps out β€” IP23 protects against falling water at up to 60Β° from vertical, not against immersion.

What excitation system and voltage regulator does the 282PSL1716 1-Phase use?

Excitation is self-excited brushless with SE350E AVR, regulated by SE350E standard / PM500 / DVR2400 with PMG. Voltage regulation is held to +/-1.0%. A brushless, self-excited machine has no slip rings to maintain, which is why it is the default for standby plant. The AVR is the part that holds voltage steady under changing load β€” if voltage wanders under load, the AVR is the first thing to check.

How stable is the voltage output of the 282PSL1716 1-Phase?

Voltage regulation is +/-1.0% from no load to full load at the stated power factor. That is the steady-state figure; transient dips when a large motor starts are larger and are handled by the engine's response and the AVR's forcing capability, not by the regulation figure alone.

What bearing does the 282PSL1716 1-Phase use?

Bearing arrangement is sealed for life ball bearings. A single-bearing machine couples directly to the engine flywheel housing and needs no separate bedplate alignment; a two-bearing machine carries its own bearing and couples through a flexible coupling. Confirm which your engine expects before ordering.

Can the 282PSL1716 1-Phase be reconnected for a different voltage?

Winding connection is 12 re-connectable. A 12-wire reconnectable machine can be wired in series or parallel, star or delta, to deliver several voltage combinations from the same alternator. If your market runs a voltage not listed on this page, send it and we will confirm whether the winding covers it.

What standards does the 282PSL1716 1-Phase meet?

It is built to NEMA MG1-32, UL 1004, CSA C22.2 No.100, IEC 60034. These are the design and test standards the machine is verified against, not a certification mark β€” the test record and the manufacturer's declaration travel with the unit so your commissioning file is complete.

What do the 282 and 1716 designations mean?

The frame code 282 identifies the mechanical size of the machine in the Marathon PSL range, and the core sits 6 of 6 in PSL family. Within one frame the core length letter steps from short to long, and each step adds lamination stack and therefore output without changing the mounting dimensions. That is why two alternators with the same frame but different core letters are physically interchangeable but electrically different.

What is the nearest alternative rating to the 282PSL1716 1-Phase?

In the same frame family, 282PSL1705 3-Phase at 20 kW / 283PSL1717 1-Phase at 30 kW. Because the mounting dimensions are shared, stepping one core length up or down is usually a direct swap β€” useful when a load calculation lands between two catalogue ratings. Confirm the engine can carry the higher figure before you step up.

What altitude is the 282PSL1716 1-Phase rated for?

The rating assumes an installation altitude of 1000 m. Above that, cooling air is thinner and the machine must be derated β€” roughly 1% of output per additional 100 m. If your site is higher, tell us the altitude and we will quote the next frame up rather than let the alternator run hot.

Is the 282PSL1716 1-Phase in stock, and what warranty comes with it?

IN STOCK, Same day shipping Worldwide available. Condition: Brand New, 3 Years International Warranty. Consumables and common frame sizes ship from stock; less common windings are built to order. Send the engine model and the required voltage and we will confirm fitment against your set before the order is placed.