Product Overview
Model. The PI144D2 is a Stamford PI 2-pole alternator. Stamford designates the frame by the number in the model (144) and the core length by the letter that follows it (D). Within one frame the letter runs from short to long, and each step adds lamination stack and therefore output. The trailing digit is a winding or revision suffix, not a rating change. It is wound for three-phase service at 60 Hz. Electrical rating. At 0.8 power factor lagging this machine is rated 19 kW, which is 23.8 kVA, delivered as three-phase at 480 V 60 Hz. At 480 V line-to-line that is 28.6 A per line. Small frames like this are sensitive to load power factor: running them well below 0.8 PF pushes the field current up and the stator current up at the same kW, so the nameplate kVA is the number to design to. The 3600 rpm figure is synchronous speed, so there is no slip and no speed-dependent voltage droop. Frame and core. As built, this machine weighs 120.5 kg (1-bearing) / 118.8 kg (2-bearing), stator 44 kg, rotor 41.87 kg, crate 71 x 51 x 67 cm. The cooling circuit is 0.100 m3/s (212 cfm) 50 Hz / 0.122 m3/s (251 cfm) 60 Hz at PI144, and the frame is steel frame, cast iron end shields. Three-phase winding. This is a three-phase machine with a 12 re-connectable winding brought out to 12 re-connectable terminals, so it can be reconnected on site for the usual voltage pairs β 380/220 V, 400/230 V, 415/240 V, 440/254 V and 480/277 V on the 50 Hz build, and the 60 Hz pairs on the 60 Hz build. Reconnection is done on the link board inside the terminal box, not by rewinding, which is why one machine can serve a 380 V job and a 480 V job. The 2/3 pitch design is what keeps the fifth and seventh space harmonics down without skewing the stator, and it is the reason the line-to-line waveform stays within the distortion limits the standards ask for. Two-pole build. A two-pole machine turns at 3000 rpm on 50 Hz and 3600 rpm on 60 Hz, so it is roughly half the iron and half the weight of a four-pole machine of the same kVA. The trade is that the rotor surface speed and the fan noise both go up, the bearing life shortens, and the subtransient reactance falls β which actually helps motor starting but makes parallel operation with other sets a little less forgiving. Two-pole alternators are the right answer where weight and footprint matter more than acoustic signature, which is why they dominate portable and skid-mounted sets. Excitation and voltage regulation. The excitation system is self-excited, brushless, regulated by AS480 (+/-1.0%), holding steady-state voltage to +/-1.0%. The MX321 and MX341 regulators are the two standard AVRs on this frame. MX321 holds +/-0.5% and adds three-phase sensing plus over-excitation and under-excitation limiting; MX341 holds +/-1.0% with single-phase sensing and is the cheaper option where the load is well behaved. Both are fed from a separate auxiliary winding, so the excitation supply does not collapse when the main output is shorted β which is what gives the machine its three-times-full-load fault current for ten seconds. Mechanical build. The frame is steel frame, cast iron end shields. Bearings are BALL.6309-2RS drive end / BALL.6306-2RS non-drive end (PI144). Mounting is single bearing SAE flange or two bearing. Maximum overspeed is 2250 rpm, and the machine is rated for 1000 m. The stator winding is double-layer concentric, and the rotor is balanced to better than BS6861 Part 1 Grade 2.5, which is what keeps vibration low enough for a set that will sit on a skid in a plant room. Derating for a dirty environment is 5% with an inlet filter fitted, 3% per 500 m above 1,000 m, and 3% per 5 degrees C above 40 degrees C ambient. Where it fits. Small standby work: a shop till and lighting circuit, a telecom cabinet, a remote monitoring station, or a single-phase domestic changeover. At this size the alternator is usually the cheapest way to get clean power onto a load that the grid only abandons a few hours a year. On a three-phase machine of 19 kW the practical constraint is usually the downstream protection and the cable, not the alternator itself. Core stack position. The D core is stack position 1 of 7 in the PI family, roughly 14% of the way along the family's lamination length range. It is the shortest stack the PI family is built with. Short-stack builds like this one are picked when the set has to fit a compact canopy or a tight skid: the frame carries the rating with the least iron and the shortest overall length, at the cost of a slightly higher flux density in the teeth and a little more excitation current at part load. Where it sits in the range. The PI family is catalogued from 8 kW up to 2300 kW, and this page covers the 19 kW / 23.8 kVA point. The step below it is the PI044G 3-Phase at 16 kW, 20 kVA. The step above it is the PI044H 3-Phase at 20 kW, 25 kVA. If your load sits between two steps, take the higher one and let the engine run at part load rather than pushing the smaller machine to its limit on a hot afternoon. Reading the model code. A Stamford designation is read as the family letters (UCI, UCDI, HCI, PI, LVSI), a three-digit frame number, a core letter, and an optional winding suffix. Here that gives PI144D2 for the model, 144 for the frame, D for the core and three for the phase count, so the code on the nameplate and the code on this page match one for one. Quoting the full code rather than just the frame matters on this family, because the same frame number is built in several core lengths and the winding changes with the voltage. Frame position. The PI range is built on 3 frame sizes β 44, 144, 734 β and the 144 frame is number 2 of them. The same 19 kW rating is also catalogued on the 044 frame as the PI044D2. The 044 is the smaller of the two, so it is shorter and lighter and is the one to quote when the skid or the canopy is the limiting dimension. The 144 carries the same rating with more iron around it, which shows up as lower flux density, a cooler core and more headroom when site ambient runs above 40 C. What the nameplate means once it is wired in. At 19 kW and 23.8 kVA this machine pushes 29 A down each line on a 480 V three-phase supply. That current, not the kVA figure, is what the switchgear and the cable have to survive, so the outgoing breaker should be a 63 A frame device set to trip above 36 A, and the run from the alternator terminals to the first panel should be 16 mm2 copper per phase for a normal 25 to 30 m span. Longer runs, aluminium conductors or tray-installed cable all move that number up, and the volt drop at full load is what decides it in the end. On the mechanical side the prime mover has to deliver about 21.3 kW at the coupling. The usual 1.10 to 1.15 margin over the alternator rating covers the fan, the excitation loss and the governor droop, and it is the reason a 19 kW alternator is normally quoted against a 21.3 kW engine rather than a 19 kW one. Fuel burn follows the electrical load almost linearly in this range. At a realistic 0.29 L per kWh for a modern common-rail set, running this alternator at full rating takes roughly 6 L per hour; at 75 per cent load it drops to about 4 L per hour and at half load to about 3 L per hour, because the fixed losses stay put while the variable ones fall away. Quote the breaker frame, the cable size and the engine rating together with the alternator, because a set that is right on paper and undersized on the cable is the most common way a good alternator gets blamed for a bad installation. Where this rating sits in the frame ladder. Within the 144 frame PI carries 2 distinct ratings, and this is number 1 of them at 19 kW. This is the smallest rating the 144 frame carries; the step above is the PI144K2 at 42.5 kW / 53.1 kVA, 23.5 kW over it. Every step inside one frame is one more lamination stack length. The shaft, the bearings, the foot pattern, the terminal box and the AVR are the same part across the whole ladder, and only the core length and the winding change. That is why the price gap between two neighbouring steps is small while the gap between the last step of one frame and the first step of the next is large. It also sets the value-engineering rule: dropping one core size inside the frame saves money and axial length but eats the margin to the load, while stepping up one size costs far less than jumping to the next frame and buying a bigger skid, a bigger breaker and a bigger cable with it. Supply. Supplied as a genuine Stamford unit β Cummins Generator Technologies, built in United Kingdom. the Stamford mark is owned by Cummins Generator Technologies and the machines are built in their own plants. Each alternator ships with the routine test certificate, the winding connection diagram, and the AVR commissioning sheet. Export packing is seaworthy plywood on a pallet sized to the frame, and the machine is strapped and shrink-wrapped inside it. Tell us the engine make and model, the coupling arrangement (single or two bearing), the voltage and frequency, and whether you need a PMG, and we will confirm the build before it leaves the works.