BASLER BE2000E Analogue AVR - Analogue Automatic Voltage Regulator for BASLER Alternators | OEM Replacement

BE2000E

Status: IN STOCK, Same day shipping Worldwide available | Brand New, 1 Year International Warranty

* Contact us for pricing and full specifications

๐Ÿ“ž Get a Quote๏ผš86-13553838770
โ† Back to products

Specifications

SKUBE2000E
BrandBASLER
Model NumberBE2000E
Regulator TypeAnalogue Automatic Voltage Regulator
Excitation SystemSelf-excited
Sensing InputSingle-phase sensing, jumper-selectable
Power InputSingle-phase, 50 / 60 Hz
Output Voltage63 Vdc class
Continuous Field Current4-6 Adc continuous
Forcing CurrentShort-term forcing current available for load steps
Field Resistance (Min)15 ohm minimum
Regulation Accuracy+/-1.0 per cent
Response TimeAbout 20 ms
Frequency Range50 / 60 Hz
Under-Frequency ProtectionVolts-per-hertz roll-off
Voltage AdjustmentInternal trim potentiometer
Paralleling / DroopReactive droop via CT
Build-Up VoltageBuilds up from residual voltage
Thermal DriftLow thermal drift
Operating Temperature-40 to +60 degC
Storage Temperature-40 to +85 degC
Protection FeaturesOver-excitation shutdown
Compatible AlternatorsSmall and mid-size alternators
MountingPanel Mount with Integrated Heat Sink
Dimensions (L x W x H)4.5" x 5.0" x 2.0" (114mm x 127mm x 51mm)
WeightApproximately 1.2 lbs (0.54 kg)
Lifecycle StatusIn production
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 1 Year International Warranty
Warranty1 Year International Warranty

Product Overview

Position in the range. The BE2000E sits in the BASLER regulator family carrying the designation Analogue Automatic Voltage Regulator. Its place is defined by the field current it can hold, 4-6 Adc continuous, against the field resistance it can drive, 15 ohm, at +/-1.0 per cent accuracy over -40 to +60 degC. Where a machine falls outside either of the first two figures, a different member of the same family is the correct answer rather than a workaround.

Excitation architecture. Self-excited. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. Take a photograph of the terminal block before removing anything. Wiring drawings for older machines are frequently wrong, and the photograph is the only reliable record.

Sensing. Single-phase sensing, jumper-selectable. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.

Power stage and field drive. Power input Single-phase, 50 / 60 Hz, output 63 Vdc class. Field current rating 4-6 Adc continuous, forcing capability Short-term forcing current available for load steps, field resistance window 15 ohm. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Where a board has been superseded, the replacement usually fits the same footprint but not the same terminal numbering. Read the drawing, do not read the old wiring.

Accuracy and response. +/-1.0 per cent steady-state accuracy, About 20 ms, thermal drift Low thermal drift. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Load sharing between parallel sets is set up with an instrument, not by ear. A droop adjustment made by listening to the sets will be wrong at every load other than the one it was set at.

Frequency behaviour. Rated for 50 / 60 Hz, with Volts-per-hertz roll-off. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. A regulator rated for a minimum field resistance of a few ohms will not drive a high resistance field to full current, however good its specification looks on paper.

Paralleling. Reactive droop via CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. If two identical sets behave differently on the same load, swap the regulators before swapping anything else. The result tells you which side of the machine the fault is on.

Protection built into the regulator. Over-excitation shutdown. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. Load sharing between parallel sets is set up with an instrument, not by ear. A droop adjustment made by listening to the sets will be wrong at every load other than the one it was set at.

What it fits. Small and mid-size alternators. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. The trim potentiometer is not a calibration device. If rated voltage is not reachable near the middle of its range, the sensing tap is wrong.

Field notes on this model. The BE series is Basler's economy analogue regulator line, built as a cost-effective replacement for the AVC63 family on volume OEM work. Electrically it behaves like an AVC63; what changes is the housing and the terminal block, so the mounting footprint has to be checked before ordering.

The retrofit case. Most BE2000E sales are retrofits, not new build. The machine is ten to twenty years old, the original board has failed, and the drawing is gone. In that situation the useful evidence is the exciter field resistance measured with a meter, the residual voltage measured at the AVR terminals with the machine turning at rated speed and no load, and the nameplate kVA. Those three readings will identify a compatible board even when the original part number cannot be found anywhere.

Earthing and shielding. The regulator reference is the machine frame. Bond the AVR mounting plate to the frame with a dedicated conductor rather than relying on the mounting screws, and earth the sensing cable shield at one end only. When a set shows a voltage that wanders slowly with no load change, the cause is usually a circulating current in the shield rather than a failing board.

Under-frequency check. Run the set at reduced speed and confirm the volts-per-hertz knee actually operates. This test is skipped on most commissioning sheets and it is the one that saves an engine on a real overload, because the knee is what stops the alternator from loading a lugging engine into a stall.

Measure, do not assume. Nameplate field resistance figures are nominal at 20 degC and are frequently wrong after a rewind. Take the measurement with a four-wire meter if one is available, because a two-wire reading on a low resistance winding includes the lead resistance and can be off by twenty per cent.

Do not overlook the obvious. Before condemning a regulator, confirm the engine is actually at rated speed. A set running five per cent slow will show low voltage on any board, and replacing the AVR will not fix a governor.

New, old stock or refurbished. Discontinued regulators are available as new old stock, which is genuine and works, and as refurbished, which is a gamble on how the board was stored. Ask which one is being quoted. A board that has spent ten years in a damp warehouse has aged electrolytics even though it has never been installed.

The retrofit case. Most BE2000E sales are retrofits, not new build. The machine is ten to twenty years old, the original board has failed, and the drawing is gone. In that situation the useful evidence is the exciter field resistance measured with a meter, the residual voltage measured at the AVR terminals with the machine turning at rated speed and no load, and the nameplate kVA. Those three readings will identify a compatible board even when the original part number cannot be found anywhere.

Documentation that survives the job. Photograph the terminal block before disconnecting anything, and write the sensing tap and the field resistance on the inside of the terminal box lid. Ten years later that note is the only thing that will let the next engineer choose a replacement without a full survey.