Home > VOLTAGE REGULATORS > GRT8-TH1 50A - Grameyer
GRAMEYER GRT8-TH1 50A Analogue AVR | Voltage Regulator | Jinjia Power

GRAMEYER GRT8-TH1 50A Analogue AVR - Analogue Automatic Voltage Regulator for GRAMEYER Alternators | OEM Replacement

GRT8-TH1 50A

Status: IN STOCK, Same day shipping Worldwide available | Brand New, 1 Year International Warranty

* Contact us for pricing and full specifications

πŸ“ž Get a Quote:86-13553838770
← Back to products

Specifications

SKUGRT8-TH1 50A
BrandGRAMEYER
Model NumberGRT8-TH1 50A
Regulator TypeAnalogue Automatic Voltage Regulator, high current
Excitation SystemSelf-excited, shunt fed
Sensing InputSingle-phase sensing, 160-300 Vac or 320-600 Vac
Power Input170-300 Vac single-phase or two-phase, 50 / 60 Hz
Output Voltage76.5-126 Vdc
Continuous Field Current50 A continuous
Forcing Current70 A for 10 s
Field Resistance (Min)6-50 ohm
Regulation Accuracy0.5 per cent static
Response TimeAdjustable from 8 to 500 ms
Frequency Range50 / 60 Hz
Under-Frequency ProtectionAdjustable under-frequency protection
Voltage AdjustmentInternal trim potentiometer
Paralleling / DroopReactive droop for parallel operation
Build-Up VoltageBuilds up from residual voltage
Thermal DriftLow thermal drift
Operating Temperature-20 to +60 degC
Storage Temperature-40 to +85 degC
Protection FeaturesUnder-frequency, over-excitation
Compatible AlternatorsLarge frame alternators, 1000 kVA and above
MountingPanel or terminal-box mount
Lifecycle StatusIn production
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 1 Year International Warranty
Warranty1 Year International Warranty

Product Overview

What the GRT8-TH1 50A is. A Analogue Automatic Voltage Regulator, high current built by GRAMEYER for brushless excitation systems. On paper the specification is a list; in service it is a set of limits. The current the board will hold indefinitely is 50 A continuous; the field resistance window it will drive without exceeding its output voltage is 6-50 ohm; the tightest voltage band it can maintain is 0.5 per cent; and the ambient range in which all of that remains true is -20 to +60 degC.

Excitation architecture. Self-excited, shunt fed. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. Take a photograph of the terminal block before removing anything. Wiring drawings for older machines are frequently wrong, and the photograph is the only reliable record.

Sensing. Single-phase sensing, 160-300 Vac or 320-600 Vac. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Counterfeit regulators are a real problem on the widely copied boards. Buy from a source that will state where the board was made.

Power stage and field drive. Power input 170-300 Vac single-phase or two-phase, 50 / 60 Hz, output 76.5-126 Vdc. Field current rating 50 A continuous, forcing capability 70 A for 10 s, field resistance window 6-50 ohm. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. A regulator rated for a minimum field resistance of a few ohms will not drive a high resistance field to full current, however good its specification looks on paper.

Accuracy and response. 0.5 per cent steady-state accuracy, Adjustable from 8 to 500 ms, thermal drift Low thermal drift. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Conformal coating is the difference between a board that survives a coastal site and one that corrodes quietly in eighteen months.

Frequency behaviour. Rated for 50 / 60 Hz, with Adjustable under-frequency protection. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. A regulator is a closed loop with a slow plant attached, and the plant is a large inductance. That is why the stability adjustment exists and why it is set after, not before, the voltage is correct.

Paralleling. Reactive droop for parallel operation. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. If the machine will not hold voltage at all, disconnect the field and measure the sensing voltage first. That one reading separates a sensing fault from a field fault.

Protection built into the regulator. Under-frequency, over-excitation. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. On a machine that has been standing for months, check residual voltage before condemning anything: a winding that has lost its remanence will not build up on any regulator.

What it fits. Large frame alternators, 1000 kVA and above. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. If the machine will not hold voltage at all, disconnect the field and measure the sensing voltage first. That one reading separates a sensing fault from a field fault.

Field notes on this model. The GRT8-TH1 is Grameyer's high-current range, built for alternators whose exciter field takes tens of amps. The suffix is the continuous field current, so the board has to match the alternator frame. Putting a 10 A board on a machine that needs 130 A will not simply under-perform, it will fail. These boards carry a substantial heatsink and are physically much larger than a TH4.

Matching the board to the duty, not to the label. Two GRAMEYER alternators of the same kVA can need different regulators if one is specified for motor starting and the other for a resistive load. The GRT8-TH1 50A is specified at 0.5 per cent static regulation accuracy, which is the number that matters when the load is a mix of drives and lighting. For a purely resistive load even a looser board is invisible to the customer, and paying for accuracy that nobody measures is the most common way money is wasted on a rebuild.

Wiring practice that prevents most call-backs. Run the sensing leads as a twisted pair, separate from the field cables, and land them on the terminals the drawing names rather than on the ones that happen to be nearest. On a GRT8-TH1 50A the sensing input draws very little current, which is exactly why it is vulnerable: a loose terminal adds resistance that the regulator reads as a voltage error and corrects by pushing the field up, so the machine runs hot and high for no visible reason.

Commissioning sequence. Start with the machine at rated speed, no load, and the field disconnected. Confirm the sensing voltage at the AVR terminals is inside the window the board expects, then connect the field with the voltage trim at minimum. Bring the trim up slowly and watch the field current, not the terminal voltage, because the terminal voltage will look correct long before the field current has stabilised on a cold winding.

The field resistance check. Measure the exciter field with the regulator disconnected and the machine stopped, then measure again after a run. Cold resistance is what the board sees at start-up; hot resistance is what it sees at full load. The GRT8-TH1 50A is specified with a minimum of 6-50 ohm, and the real question is not whether the measured value is above that figure but whether the forcing current at that resistance still reaches the level the alternator needs to recover from a load step.

Intermittent loss of excitation. Intermittent faults are almost always mechanical: a crimp that was never properly made, a terminal screw that was tightened onto insulation, or a board that is flexing. Wiggle-test the harness with the machine running at no load and watch the field current meter.

Delivery and packing. Regulators are static-sensitive assemblies and should arrive in a sealed bag with foam, not loose in a box with a heatsink. Inspect on arrival and photograph the packaging before opening if there is any sign of crush damage.

Reading the application backwards. Most regulator problems arrive described as engine trouble. A set that hunts on load, or whose voltage sags for two seconds after a contactor closes, is usually reporting a field current limit rather than a fuel problem. On a GRT8-TH1 50A the first thing to check is whether the 50 A continuous figure is being reached on a cold morning, because field resistance rises with temperature in the opposite direction to copper and a board that is marginal at 20 degC can be comfortable at 50 degC or the other way round depending on the winding.

Power and sensing are not the same circuit. The power input on a GRT8-TH1 50A can come from a different winding from the sensing input, and on PMG machines it always does. Wire them as two separate circuits, fused separately, and label both. The single most expensive mistake on a PMG set is landing the sensing leads on the PMG supply, which gives the regulator a voltage reference that rises with speed and produces a set whose voltage tracks engine rpm.