Home > VOLTAGE REGULATORS > AVC125-10B1 Basler AVR โ€“ Automatic Voltage Regulator
BASLER AVC125-10B1 Analogue AVR | Voltage Regulator | Jinjia Power

BASLER AVC125-10B1 Analogue AVR - Analogue Automatic Voltage Regulator for BASLER Alternators | OEM Replacement

AVC125-10B1

Status: IN STOCK, Same day shipping Worldwide available | Brand New, 1 Year International Warranty

* Contact us for pricing and full specifications

๐Ÿ“ž Get a Quote๏ผš86-13553838770
โ† Back to products

Specifications

SKUAVC125-10B1
BrandBASLER
Model NumberAVC125-10B1
Regulator TypeAnalogue Automatic Voltage Regulator
Excitation SystemSelf-excited or PMG
Sensing InputSingle-phase or three-phase, 380-480 V class
Power InputSingle-phase, 50 / 60 Hz
Output Voltage125 Vdc class
Continuous Field Current10 Adc continuous
Forcing Current15 Adc for 10 s
Field Resistance (Min)18 ohm minimum
Regulation Accuracy+/-1.0 per cent
Response TimeAbout 20 ms
Frequency Range50 / 60 Hz
Under-Frequency ProtectionVolts-per-hertz roll-off
Voltage AdjustmentInternal trim potentiometer
Paralleling / DroopReactive droop via CT
Build-Up VoltageBuilds up from residual voltage
Thermal Drift0.05 per cent per degC
Operating Temperature-40 to +60 degC
Storage Temperature-40 to +85 degC
Protection FeaturesOver-excitation shutdown, integral fuse
Compatible AlternatorsLarge frame alternators, 1000-2500 kVA
MountingPanel or chassis mount with securing hardware
Dimensions (L x W x H)Approximately 7.5" x 5.0" x 2.5"
WeightApproximately 2.8 lbs (1.3 kg)
Lifecycle StatusIn production
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 1 Year International Warranty
Warranty1 Year International Warranty

Product Overview

What the AVC125-10B1 is. A Analogue Automatic Voltage Regulator built by BASLER for brushless excitation systems. On paper the specification is a list; in service it is a set of limits. The current the board will hold indefinitely is 10 Adc continuous; the field resistance window it will drive without exceeding its output voltage is 18 ohm; the tightest voltage band it can maintain is +/-1.0 per cent; and the ambient range in which all of that remains true is -40 to +60 degC.

Excitation architecture. Self-excited or PMG. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. If the machine will not hold voltage at all, disconnect the field and measure the sensing voltage first. That one reading separates a sensing fault from a field fault.

Sensing. Single-phase or three-phase, 380-480 V class. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Take a photograph of the terminal block before removing anything. Wiring drawings for older machines are frequently wrong, and the photograph is the only reliable record.

Power stage and field drive. Power input Single-phase, 50 / 60 Hz, output 125 Vdc class. Field current rating 10 Adc continuous, forcing capability 15 Adc for 10 s, field resistance window 18 ohm. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. The cheapest diagnostic tool in excitation work is a DC ammeter in the field circuit. It turns a vague symptom into a number within seconds.

Accuracy and response. +/-1.0 per cent steady-state accuracy, About 20 ms, thermal drift 0.05 per cent per degC. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. The trim potentiometer is not a calibration device. If rated voltage is not reachable near the middle of its range, the sensing tap is wrong.

Frequency behaviour. Rated for 50 / 60 Hz, with Volts-per-hertz roll-off. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. Never flash a field through the regulator. Disconnect the board, flash the field directly, then reconnect. Flashing through the AVR is how a working board becomes a failed board.

Paralleling. Reactive droop via CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. If two identical sets behave differently on the same load, swap the regulators before swapping anything else. The result tells you which side of the machine the fault is on.

Protection built into the regulator. Over-excitation shutdown, integral fuse. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. If the machine will not hold voltage at all, disconnect the field and measure the sensing voltage first. That one reading separates a sensing fault from a field fault.

What it fits. Large frame alternators, 1000-2500 kVA. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. The trim potentiometer is not a calibration device. If rated voltage is not reachable near the middle of its range, the sensing tap is wrong.

Field notes on this model. The AVC125-10 is the 125 Vdc member of the Basler analogue line, used where the exciter field is wound for a higher voltage and a lower current than a 63 Vdc machine. It is common on large frame alternators and on machines originally supplied with a Basler SR8A or SR9A.

The retrofit case. Most AVC125-10B1 sales are retrofits, not new build. The machine is ten to twenty years old, the original board has failed, and the drawing is gone. In that situation the useful evidence is the exciter field resistance measured with a meter, the residual voltage measured at the AVR terminals with the machine turning at rated speed and no load, and the nameplate kVA. Those three readings will identify a compatible board even when the original part number cannot be found anywhere.

Power and sensing are not the same circuit. The power input on a AVC125-10B1 can come from a different winding from the sensing input, and on PMG machines it always does. Wire them as two separate circuits, fused separately, and label both. The single most expensive mistake on a PMG set is landing the sensing leads on the PMG supply, which gives the regulator a voltage reference that rises with speed and produces a set whose voltage tracks engine rpm.

Bench test before installation. Where a spare board is available, test it on the bench with a variable AC supply into the power input and a resistor bank as the field load. A board that cannot hold a steady output into a resistor will not hold it into an exciter either, and finding that out on the bench costs nothing.

The forcing margin. A regulator that can only just hold rated voltage at rated load has no forcing margin left, and the machine will dip on every load step. The AVC125-10B1 is specified with a minimum field resistance of 18 ohm minimum; staying comfortably above that minimum, rather than exactly at it, is what leaves the forcing margin that makes a set feel solid rather than merely adequate.

Intermittent loss of excitation. Intermittent faults are almost always mechanical: a crimp that was never properly made, a terminal screw that was tightened onto insulation, or a board that is flexing. Wiggle-test the harness with the machine running at no load and watch the field current meter.

New, old stock or refurbished. Discontinued regulators are available as new old stock, which is genuine and works, and as refurbished, which is a gamble on how the board was stored. Ask which one is being quoted. A board that has spent ten years in a damp warehouse has aged electrolytics even though it has never been installed.

Matching the board to the duty, not to the label. Two BASLER alternators of the same kVA can need different regulators if one is specified for motor starting and the other for a resistive load. The AVC125-10B1 is specified at +/-1.0 per cent regulation accuracy, which is the number that matters when the load is a mix of drives and lighting. For a purely resistive load even a looser board is invisible to the customer, and paying for accuracy that nobody measures is the most common way money is wasted on a rebuild.

The terminal box is a hostile place. Engine vibration, radiant heat from the exhaust and conductive dust all arrive at the same panel. Mount the AVC125-10B1 on the resilient side of the box if there is a choice, keep it off the hottest wall, and make sure the lid actually closes over the wiring rather than pinching it. A regulator that is mechanically stressed will eventually crack a solder joint, and the resulting fault looks exactly like a failed semiconductor.