| SKU | CIN81 |
| Brand | LEROY SOMER |
| Model Number | CIN81 |
| Regulator Type | Analogue Automatic Voltage Regulator |
| Excitation System | Self-excited, shunt fed |
| Sensing Input | Single-phase sensing with voltage taps |
| Power Input | From the main stator, 50 / 60 Hz |
| Output Voltage | Up to 90 Vdc |
| Continuous Field Current | 2-4 A class |
| Forcing Current | Short-term forcing current available for load steps |
| Field Resistance (Min) | Matched to the exciter field |
| Regulation Accuracy | +/-1.0 per cent |
| Response Time | Standard analogue response |
| Frequency Range | 50 / 60 Hz |
| Under-Frequency Protection | Not published for this model - ask us for the nameplate data |
| Voltage Adjustment | Internal trim potentiometer |
| Paralleling / Droop | Reactive droop via CT |
| Build-Up Voltage | Builds up from residual voltage |
| Thermal Drift | Low thermal drift |
| Operating Temperature | -40 to +70 degC |
| Storage Temperature | -40 to +85 degC |
| Protection Features | Over-excitation protection |
| Compatible Alternators | Small and mid-size Leroy Somer alternators |
| Mounting | Panel or terminal-box mount |
| Lifecycle Status | Legacy or current depending on variant |
| Availability | IN STOCK, Same day shipping Worldwide available |
| Condition | Brand New, 1 Year International Warranty |
| Warranty | 1 Year International Warranty |
Position in the range. The CIN81 sits in the LEROY SOMER regulator family carrying the designation Analogue Automatic Voltage Regulator. Its place is defined by the field current it can hold, 2-4 A class, against the field resistance it can drive, Matched to the exciter field, at +/-1.0 per cent accuracy over -40 to +70 degC. Where a machine falls outside either of the first two figures, a different member of the same family is the correct answer rather than a workaround.
Excitation architecture. Self-excited, shunt fed. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. An alternator that has been rewound needs its field resistance re-measured, because a rewind commonly moves it by ten to twenty per cent in either direction.
Sensing. Single-phase sensing with voltage taps. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. A regulator rated for a minimum field resistance of a few ohms will not drive a high resistance field to full current, however good its specification looks on paper.
Power stage and field drive. Power input From the main stator, 50 / 60 Hz, output Up to 90 Vdc. Field current rating 2-4 A class, forcing capability Short-term forcing current available for load steps, field resistance window Matched to the exciter field. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Terminal boxes are hot, dirty and vibrating. Anything mounted inside one should be judged on how it behaves in year eight, not on how it reads on the bench.
Accuracy and response. +/-1.0 per cent steady-state accuracy, Standard analogue response, thermal drift Low thermal drift. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. The measurement that settles most arguments is the field current at full load, taken with a clamp meter, compared against the rating on the board.
Frequency behaviour. Rated for 50 / 60 Hz, with Not published for this model - ask us for the nameplate data. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. If the machine will not hold voltage at all, disconnect the field and measure the sensing voltage first. That one reading separates a sensing fault from a field fault.
Paralleling. Reactive droop via CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. If two identical sets behave differently on the same load, swap the regulators before swapping anything else. The result tells you which side of the machine the fault is on.
Protection built into the regulator. Over-excitation protection. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.
What it fits. Small and mid-size Leroy Somer alternators. Lifecycle status: Legacy or current depending on variant. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. A regulator is a closed loop with a slow plant attached, and the plant is a large inductance. That is why the stability adjustment exists and why it is set after, not before, the voltage is correct.
Field notes on this model. This is one of the compact analogue regulators used on smaller Leroy Somer alternators and on older machines that predate the R438. Field current is modest, so it suits alternators up to a few hundred kVA. Because it is shunt fed, build-up depends on residual voltage, and a machine that has been standing for months may need to be flashed before it will excite.
Matching the board to the duty, not to the label. Two LEROY SOMER alternators of the same kVA can need different regulators if one is specified for motor starting and the other for a resistive load. The CIN81 is specified at +/-1.0 per cent regulation accuracy, which is the number that matters when the load is a mix of drives and lighting. For a purely resistive load even a looser board is invisible to the customer, and paying for accuracy that nobody measures is the most common way money is wasted on a rebuild.
Earthing and shielding. The regulator reference is the machine frame. Bond the AVR mounting plate to the frame with a dedicated conductor rather than relying on the mounting screws, and earth the sensing cable shield at one end only. When a set shows a voltage that wanders slowly with no load change, the cause is usually a circulating current in the shield rather than a failing board.
Stability before accuracy. Set the stability adjustment until the voltage stops hunting on a load step, then leave it alone. Chasing the last tenth of a per cent of static accuracy by tightening stability is how a set ends up oscillating at 2 Hz under a resistive load and looking like a governor fault. The CIN81 is specified at +/-1.0 per cent; a real machine on a real load will not do better than that no matter how the trimmer is set.
Temperature drift of the field. Copper rises about 0.4 per cent in resistance per degC, so a field that measures 12 ohm cold will measure around 15 ohm at a 70 degC winding temperature. A regulator set up on a cold machine and never re-checked will therefore be running at a different operating point every time the season changes, and the symptom is a voltage that is correct in winter and low in summer.
Voltage high and unresponsive. If the machine runs to maximum excitation regardless of the trim, disconnect the field and see whether the voltage collapses. If it does, the regulator has failed shorted; if it does not, the field is being fed from somewhere else, usually a shorted thyristor or a mis-wired paralleling circuit. Do not run the machine at full excitation for more than a few seconds while diagnosing, because the winding will not survive it.
Warranty and what it covers. A one year warranty on a regulator is meaningful only if it covers a field-side failure and not just a dead-on-arrival check. Ask whether a board that fails after six months in service is replaced without argument, because that is the failure mode that actually happens.
What the customer is actually buying. When a regulator is quoted as a replacement, the buyer is not purchasing a circuit board. They are purchasing the certainty that the set will hold voltage on the next load step. On the CIN81 that certainty comes from the combination of 2-4 A class continuous field current and the Standard analogue response response, and it disappears the moment the field resistance drifts outside the window the board was set up for.
The terminal box is a hostile place. Engine vibration, radiant heat from the exhaust and conductive dust all arrive at the same panel. Mount the CIN81 on the resilient side of the box if there is a choice, keep it off the hottest wall, and make sure the lid actually closes over the wiring rather than pinching it. A regulator that is mechanically stressed will eventually crack a solder joint, and the resulting fault looks exactly like a failed semiconductor.