Home > VOLTAGE REGULATORS > GRT8-TH1 10A - Grameyer
GRAMEYER GRT8-TH1 10A Analogue AVR | Voltage Regulator | Jinjia Power

GRAMEYER GRT8-TH1 10A Analogue AVR - Analogue Automatic Voltage Regulator for GRAMEYER Alternators | OEM Replacement

GRT8-TH1 10A

Status: IN STOCK, Same day shipping Worldwide available | Brand New, 1 Year International Warranty

* Contact us for pricing and full specifications

πŸ“ž Get a Quote:86-13553838770
← Back to products

Specifications

SKUGRT8-TH1 10A
BrandGRAMEYER
Model NumberGRT8-TH1 10A
Regulator TypeAnalogue Automatic Voltage Regulator, high current
Excitation SystemSelf-excited, shunt fed
Sensing InputSingle-phase sensing, 160-300 Vac or 320-600 Vac
Power Input170-300 Vac single-phase or two-phase, 50 / 60 Hz
Output Voltage76.5-126 Vdc
Continuous Field Current10 A continuous
Forcing Current14 A for 10 s
Field Resistance (Min)6-50 ohm
Regulation Accuracy0.5 per cent static
Response TimeAdjustable from 8 to 500 ms
Frequency Range50 / 60 Hz
Under-Frequency ProtectionAdjustable under-frequency protection
Voltage AdjustmentInternal trim potentiometer
Paralleling / DroopReactive droop for parallel operation
Build-Up VoltageBuilds up from residual voltage
Thermal DriftLow thermal drift
Operating Temperature-20 to +60 degC
Storage Temperature-40 to +85 degC
Protection FeaturesUnder-frequency, over-excitation
Compatible AlternatorsLarge frame alternators, 1000 kVA and above
MountingPanel or terminal-box mount
Lifecycle StatusIn production
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 1 Year International Warranty
Warranty1 Year International Warranty

Product Overview

What the GRT8-TH1 10A is. A Analogue Automatic Voltage Regulator, high current built by GRAMEYER for brushless excitation systems. On paper the specification is a list; in service it is a set of limits. The current the board will hold indefinitely is 10 A continuous; the field resistance window it will drive without exceeding its output voltage is 6-50 ohm; the tightest voltage band it can maintain is 0.5 per cent; and the ambient range in which all of that remains true is -20 to +60 degC.

Excitation architecture. Self-excited, shunt fed. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.

Sensing. Single-phase sensing, 160-300 Vac or 320-600 Vac. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. If the machine will not hold voltage at all, disconnect the field and measure the sensing voltage first. That one reading separates a sensing fault from a field fault.

Power stage and field drive. Power input 170-300 Vac single-phase or two-phase, 50 / 60 Hz, output 76.5-126 Vdc. Field current rating 10 A continuous, forcing capability 14 A for 10 s, field resistance window 6-50 ohm. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.

Accuracy and response. 0.5 per cent steady-state accuracy, Adjustable from 8 to 500 ms, thermal drift Low thermal drift. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Any AVR that has been in service for more than ten years is running on borrowed time, and the failure always happens at the least convenient moment.

Frequency behaviour. Rated for 50 / 60 Hz, with Adjustable under-frequency protection. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. Load sharing between parallel sets is set up with an instrument, not by ear. A droop adjustment made by listening to the sets will be wrong at every load other than the one it was set at.

Paralleling. Reactive droop for parallel operation. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. The measurement that settles most arguments is the field current at full load, taken with a clamp meter, compared against the rating on the board.

Protection built into the regulator. Under-frequency, over-excitation. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. If the machine will not hold voltage at all, disconnect the field and measure the sensing voltage first. That one reading separates a sensing fault from a field fault.

What it fits. Large frame alternators, 1000 kVA and above. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. Conformal coating is the difference between a board that survives a coastal site and one that corrodes quietly in eighteen months.

Field notes on this model. The GRT8-TH1 is Grameyer's high-current range, built for alternators whose exciter field takes tens of amps. The suffix is the continuous field current, so the board has to match the alternator frame. Putting a 10 A board on a machine that needs 130 A will not simply under-perform, it will fail. These boards carry a substantial heatsink and are physically much larger than a TH4.

Matching the board to the duty, not to the label. Two GRAMEYER alternators of the same kVA can need different regulators if one is specified for motor starting and the other for a resistive load. The GRT8-TH1 10A is specified at 0.5 per cent static regulation accuracy, which is the number that matters when the load is a mix of drives and lighting. For a purely resistive load even a looser board is invisible to the customer, and paying for accuracy that nobody measures is the most common way money is wasted on a rebuild.

Mounting orientation and cooling. Most AVR boards are convection cooled and assume the heatsink fins are vertical. Mounting a GRT8-TH1 10A flat on its back inside a sealed box shortens its life even though the ambient temperature reads acceptable, because the local air around the thyristor is far hotter than the box average.

Paralleling setup. With two sets on the bus, adjust droop until reactive load divides in proportion to machine rating, then check it again at half load. A droop setting that looks right at full load and wrong at half load is usually a CT ratio error rather than a regulator fault.

Rewind caution. After a field rewind the resistance often changes by ten to twenty per cent, which can push a marginal regulator out of range. Whenever a machine comes back from a rewind, re-check the regulator against the new field resistance before returning it to service.

Intermittent loss of excitation. Intermittent faults are almost always mechanical: a crimp that was never properly made, a terminal screw that was tightened onto insulation, or a board that is flexing. Wiggle-test the harness with the machine running at no load and watch the field current meter.

Counterfeits. Where a board is widely copied, buy from a source that will state the country of manufacture and stand behind it. A counterfeit regulator usually works for a month and then fails on the first cold morning, and by then the machine has a reputation problem rather than a parts problem.

What the customer is actually buying. When a regulator is quoted as a replacement, the buyer is not purchasing a circuit board. They are purchasing the certainty that the set will hold voltage on the next load step. On the GRT8-TH1 10A that certainty comes from the combination of 10 A continuous continuous field current and the Adjustable from 8 to 500 ms response, and it disappears the moment the field resistance drifts outside the window the board was set up for.

Wiring practice that prevents most call-backs. Run the sensing leads as a twisted pair, separate from the field cables, and land them on the terminals the drawing names rather than on the ones that happen to be nearest. On a GRT8-TH1 10A the sensing input draws very little current, which is exactly why it is vulnerable: a loose terminal adds resistance that the regulator reads as a voltage error and corrects by pushing the field up, so the machine runs hot and high for no visible reason.

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China