BASLER SR9A Static AVR | Voltage Regulator | Jinjia Power

BASLER SR9A Static AVR - Static Automatic Voltage Regulator for BASLER Alternators | OEM Replacement

SR9A

Status: IN STOCK, Same day shipping Worldwide available |

* Contact us for pricing and full specifications

📞 Get a Quote:86-13553838770
← Back to products

Specifications

SKUSR9A
BrandBASLER
Model NumberSR9A
Regulator TypeStatic Automatic Voltage Regulator
Excitation SystemSelf-excited, shunt fed from the main stator
Sensing InputNEMA 120 / 208 / 240 / 416 / 480 / 600 V at 10 VA per phase; SR6A and SR9A are the 400 Hz versions
Power Input120 Vac at 840 VA (SR4A, SR6A) or 240 Vac at 1680 VA (SR8A, SR9A), 50 / 60 Hz or 400 Hz
Output Voltage63 Vdc on SR4A and SR6A, 125 Vdc on SR8A and SR9A
Continuous Field Current7 Adc continuous
Forcing Current10 Adc for 1 minute
Field Resistance (Min)9 ohm on 63 V units or 18-19 ohm on 125 V units, 400 ohm maximum
Regulation Accuracy+/-0.5 per cent on average voltage
Response TimeBetter than 17 ms
Frequency Range50 / 60 Hz on SR4A and SR8A, 400 Hz on SR6A and SR9A
Under-Frequency ProtectionNone built in, frequency compensation is external on the SR platform
Voltage Adjustment+/-10 per cent via an external potentiometer
Paralleling / DroopReactive droop, 5 A CT input at 25 VA
Build-Up VoltageBuilds up from residual voltage
Thermal Drift+/-0.5 per cent per 20 degC after a 20 minute warm-up
Operating Temperature-55 to +70 degC at 3.5 A, -55 to +55 degC at 7.0 A
Storage Temperature-65 to +100 degC
Protection FeaturesOver-excitation protection through the external limiter, integral fuse
Compatible AlternatorsLarge frame alternators, 500-3000 kVA
MountingPanel or terminal-box mount
Lifecycle StatusLegacy platform, still supported by the SR and SSR Retrofit kits
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 1 Year International Warranty
Warranty1 Year International Warranty

Product Overview

Short version. The SR9A is a Static Automatic Voltage Regulator. It supplies the exciter field, senses the alternator output and corrects the difference several times a second. Its rating is 7 Adc continuous, its field resistance window 9 ohm on 63 V units or 18-19, its accuracy +/-0.5 per cent, and it is intended for machines whose field winding sits inside that window. Read the rest of this page as the detail behind those three figures.

Excitation architecture. Self-excited, shunt fed from the main stator. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. Terminal boxes are hot, dirty and vibrating. Anything mounted inside one should be judged on how it behaves in year eight, not on how it reads on the bench.

Sensing. NEMA 120 / 208 / 240 / 416 / 480 / 600 V at 10 VA per phase; SR6A and SR9A are the 400 Hz versions. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. An alternator that has been rewound needs its field resistance re-measured, because a rewind commonly moves it by ten to twenty per cent in either direction.

Power stage and field drive. Power input 120 Vac at 840 VA (SR4A, SR6A) or 240 Vac at 1680 VA (SR8A, SR9A), 50 / 60 Hz or 400 Hz, output 63 Vdc on SR4A and SR6A, 125 Vdc on SR8A and SR9A. Field current rating 7 Adc continuous, forcing capability 10 Adc for 1 minute, field resistance window 9 ohm on 63 V units or 18-19. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Take a photograph of the terminal block before removing anything. Wiring drawings for older machines are frequently wrong, and the photograph is the only reliable record.

Accuracy and response. +/-0.5 per cent steady-state accuracy, Better than 17 ms, thermal drift +/-0.5 per cent per 20 degC after a 20 minute warm-up. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Load sharing between parallel sets is set up with an instrument, not by ear. A droop adjustment made by listening to the sets will be wrong at every load other than the one it was set at.

Frequency behaviour. Rated for 50 / 60 Hz on SR4A and SR8A, 400 Hz on SR6A and SR9A, with None built in, frequency compensation is external on the SR platform. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. A set that runs at reduced speed will show low voltage on any regulator. Check engine speed against the nameplate before touching the excitation system.

Paralleling. Reactive droop, 5 A CT input at 25 VA. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. Counterfeit regulators are a real problem on the widely copied boards. Buy from a source that will state where the board was made.

Protection built into the regulator. Over-excitation protection through the external limiter, integral fuse. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.

What it fits. Large frame alternators, 500-3000 kVA. Lifecycle status: Legacy platform, still supported by the SR and SSR Retrofit kits. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.

Field notes on this model. The Basler SR series is the classic static regulator: a magnetic amplifier front end with a silicon power stage in a ventilated steel case with screw terminals. It is still the reference AVR on a lot of large frame machines because it is repairable and because the terminals are big enough to take a real field cable. SR4A and SR8A are the 50 / 60 Hz units; SR6A and SR9A are 400 Hz versions for aircraft ground power and defence sets, and the two groups are not interchangeable.

Matching the board to the duty, not to the label. Two BASLER alternators of the same kVA can need different regulators if one is specified for motor starting and the other for a resistive load. The SR9A is specified at +/-0.5 per cent on average voltage regulation accuracy, which is the number that matters when the load is a mix of drives and lighting. For a purely resistive load even a looser board is invisible to the customer, and paying for accuracy that nobody measures is the most common way money is wasted on a rebuild.

Fusing. Fit the fuse the manual specifies and nothing larger. A bigger fuse does not protect the regulator better, it protects it later. On a SR9A the fuse is there to clear a field short before the thyristor is destroyed, and a 20 A fuse in place of an 8 A one turns a cheap board replacement into a rewind.

Load step test. Apply and remove at least half rated load and watch the recovery. A healthy regulator pulls the voltage back inside one per cent within a few cycles. If the recovery is slow but the final voltage is correct, the problem is response, not accuracy, and on an analogue board that usually means the field circuit is seeing more resistance than it was set up for.

Measure, do not assume. Nameplate field resistance figures are nominal at 20 degC and are frequently wrong after a rewind. Take the measurement with a four-wire meter if one is available, because a two-wire reading on a low resistance winding includes the lead resistance and can be off by twenty per cent.

Voltage drifts with ambient temperature. If the voltage is correct cold and low hot, the thermal drift of the regulator and the temperature coefficient of the field are adding up in the same direction. The SR9A is specified at +/-0.5 per cent on average voltage; a drift of a couple of per cent over a fifty degree swing is normal for an analogue board and is not a fault.

Lifecycle status. If the board being replaced is discontinued, price the current replacement at the same time as the old-stock option. On a machine that is going to run for another ten years the current production board is almost always the cheaper decision even when the old stock is available.

Standby versus prime power. A standby set runs a few hundred hours a year and its regulator spends most of its life cold; a prime power set runs continuously and its regulator spends its life at operating temperature. The SR9A is rated for -55 to +70 degC at 3.5 A, -55 to +55 degC at 7.0 A, which is fine in both cases provided the terminal box has any ventilation at all. What changes between the two duties is the capacitor ageing inside the board, not the semiconductor, so a prime power machine should have the regulator inspected on a schedule rather than on failure.

Fusing. Fit the fuse the manual specifies and nothing larger. A bigger fuse does not protect the regulator better, it protects it later. On a SR9A the fuse is there to clear a field short before the thyristor is destroyed, and a 20 A fuse in place of an 8 A one turns a cheap board replacement into a rewind.