Status: IN STOCK, Same day shipping Worldwide available |
* Contact us for pricing and full specifications
| SKU | K125-10B |
| Brand | KATO |
| Model Number | K125-10B |
| Regulator Type | Analogue Automatic Voltage Regulator |
| Excitation System | Self-excited or PMG depending on variant |
| Sensing Input | Single-phase or three-phase sensing with voltage taps |
| Power Input | From the main stator, 50 / 60 Hz |
| Output Voltage | 63-125 Vdc class |
| Continuous Field Current | 4-10 A class |
| Forcing Current | Short-term forcing current available for load steps |
| Field Resistance (Min) | Matched to the exciter field |
| Regulation Accuracy | +/-1.0 per cent |
| Response Time | Standard analogue response |
| Frequency Range | 50 / 60 Hz |
| Under-Frequency Protection | Volts-per-hertz roll-off |
| Voltage Adjustment | Internal trim potentiometer |
| Paralleling / Droop | Reactive droop via CT |
| Build-Up Voltage | Builds up from residual voltage |
| Thermal Drift | Low thermal drift |
| Operating Temperature | -40 to +60 degC |
| Storage Temperature | -40 to +85 degC |
| Protection Features | Over-excitation shutdown, loss of sensing |
| Compatible Alternators | Kato Engineering alternators |
| Mounting | Panel or terminal-box mount |
| Lifecycle Status | In production |
| Availability | IN STOCK, Same day shipping Worldwide available |
| Condition | Brand New, 1 Year International Warranty |
| Warranty | 1 Year International Warranty |
KATO K125-10B. This is a Analogue Automatic Voltage Regulator from the KATO range, supplied as a direct replacement for the same model number in the field. The figures that matter are printed in the table above and repeated here so the page can be read on its own: field current rating 4-10 A class, field resistance window Matched to the exciter field, accuracy +/-1.0 per cent, working range -40 to +60 degC. Everything else on this page exists to explain how those four numbers decide whether the unit fits a particular alternator.
Excitation architecture. Self-excited or PMG depending on variant. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. Conformal coating is the difference between a board that survives a coastal site and one that corrodes quietly in eighteen months.
Sensing. Single-phase or three-phase sensing with voltage taps. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Load sharing between parallel sets is set up with an instrument, not by ear. A droop adjustment made by listening to the sets will be wrong at every load other than the one it was set at.
Power stage and field drive. Power input From the main stator, 50 / 60 Hz, output 63-125 Vdc class. Field current rating 4-10 A class, forcing capability Short-term forcing current available for load steps, field resistance window Matched to the exciter field. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Load sharing between parallel sets is set up with an instrument, not by ear. A droop adjustment made by listening to the sets will be wrong at every load other than the one it was set at.
Accuracy and response. +/-1.0 per cent steady-state accuracy, Standard analogue response, thermal drift Low thermal drift. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Terminal boxes are hot, dirty and vibrating. Anything mounted inside one should be judged on how it behaves in year eight, not on how it reads on the bench.
Frequency behaviour. Rated for 50 / 60 Hz, with Volts-per-hertz roll-off. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. If two identical sets behave differently on the same load, swap the regulators before swapping anything else. The result tells you which side of the machine the fault is on.
Paralleling. Reactive droop via CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. Terminal boxes are hot, dirty and vibrating. Anything mounted inside one should be judged on how it behaves in year eight, not on how it reads on the bench.
Protection built into the regulator. Over-excitation shutdown, loss of sensing. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. A regulator rated for a minimum field resistance of a few ohms will not drive a high resistance field to full current, however good its specification looks on paper.
What it fits. Kato Engineering alternators. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. Where a board has been superseded, the replacement usually fits the same footprint but not the same terminal numbering. Read the drawing, do not read the old wiring.
Field notes on this model. Kato regulators are built for the alternator they are shipped with, so the model number is tied to the machine frame. On a replacement order the alternator nameplate data, meaning kVA, voltage and field resistance, is what determines the correct board, not the regulator part number alone.
Reading the application backwards. Most regulator problems arrive described as engine trouble. A set that hunts on load, or whose voltage sags for two seconds after a contactor closes, is usually reporting a field current limit rather than a fuel problem. On a K125-10B the first thing to check is whether the 4-10 A class figure is being reached on a cold morning, because field resistance rises with temperature in the opposite direction to copper and a board that is marginal at 20 degC can be comfortable at 50 degC or the other way round depending on the winding.
The terminal box is a hostile place. Engine vibration, radiant heat from the exhaust and conductive dust all arrive at the same panel. Mount the K125-10B on the resilient side of the box if there is a choice, keep it off the hottest wall, and make sure the lid actually closes over the wiring rather than pinching it. A regulator that is mechanically stressed will eventually crack a solder joint, and the resulting fault looks exactly like a failed semiconductor.
Stability before accuracy. Set the stability adjustment until the voltage stops hunting on a load step, then leave it alone. Chasing the last tenth of a per cent of static accuracy by tightening stability is how a set ends up oscillating at 2 Hz under a resistive load and looking like a governor fault. The K125-10B is specified at +/-1.0 per cent; a real machine on a real load will not do better than that no matter how the trimmer is set.
Why resistance matters more than current rating. A regulator delivers a voltage, and the field decides how much current that voltage produces. A board rated at 4-10 A class into a low resistance field will deliver far less into a high resistance one, because the output voltage is the limit. This is why an AVR that is electrically perfect on paper can fail to excite a particular alternator, and why the resistance figure belongs in the quotation rather than in the manual.
Voltage high and unresponsive. If the machine runs to maximum excitation regardless of the trim, disconnect the field and see whether the voltage collapses. If it does, the regulator has failed shorted; if it does not, the field is being fed from somewhere else, usually a shorted thyristor or a mis-wired paralleling circuit. Do not run the machine at full excitation for more than a few seconds while diagnosing, because the winding will not survive it.
Warranty and what it covers. A one year warranty on a regulator is meaningful only if it covers a field-side failure and not just a dead-on-arrival check. Ask whether a board that fails after six months in service is replaced without argument, because that is the failure mode that actually happens.
Matching the board to the duty, not to the label. Two KATO alternators of the same kVA can need different regulators if one is specified for motor starting and the other for a resistive load. The K125-10B is specified at +/-1.0 per cent regulation accuracy, which is the number that matters when the load is a mix of drives and lighting. For a purely resistive load even a looser board is invisible to the customer, and paying for accuracy that nobody measures is the most common way money is wasted on a rebuild.
Field cable sizing. The field circuit carries DC at low voltage and high current, so volt drop matters more than ampacity. Size the cable so that the drop at 4-10 A class stays under about one volt, and torque the terminals to the manufacturer figure. A field circuit that loses half a volt in the cable is a regulator that cannot reach full forcing when the load steps.