| SKU | 036-245 |
| Brand | MARKON |
| Model Number | 036-245 |
| Regulator Type | Analogue Automatic Voltage Regulator |
| Excitation System | Self-excited, shunt fed |
| Sensing Input | Single-phase sensing with voltage taps |
| Power Input | From the main stator, 50 / 60 Hz |
| Output Voltage | 63 Vdc class |
| Continuous Field Current | 4 A class |
| Forcing Current | Short-term forcing current available for load steps |
| Field Resistance (Min) | 15 ohm minimum |
| Regulation Accuracy | +/-1.0 per cent |
| Response Time | Standard analogue response |
| Frequency Range | 50 / 60 Hz |
| Under-Frequency Protection | Not published for this model - ask us for the nameplate data |
| Voltage Adjustment | Internal trim potentiometer |
| Paralleling / Droop | Reactive droop via CT |
| Build-Up Voltage | Builds up from residual voltage |
| Thermal Drift | Low thermal drift |
| Operating Temperature | -30 to +70 degC |
| Storage Temperature | -40 to +85 degC |
| Protection Features | Over-excitation shutdown |
| Compatible Alternators | Markon and Newage BL series alternators |
| Mounting | Standard mounting holes for alternator installation |
| Weight | Approximately 0.4 kg (0.88 lbs) |
| Lifecycle Status | Legacy, conversion to a current board recommended |
| Availability | IN STOCK, Same day shipping Worldwide available |
| Condition | Brand New, 1 Year International Warranty |
| Warranty | 1 Year International Warranty |
What the 036-245 is. A Analogue Automatic Voltage Regulator built by MARKON for brushless excitation systems. On paper the specification is a list; in service it is a set of limits. The current the board will hold indefinitely is 4 A class; the field resistance window it will drive without exceeding its output voltage is 15 ohm; the tightest voltage band it can maintain is +/-1.0 per cent; and the ambient range in which all of that remains true is -30 to +70 degC.
Excitation architecture. Self-excited, shunt fed. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. Take a photograph of the terminal block before removing anything. Wiring drawings for older machines are frequently wrong, and the photograph is the only reliable record.
Sensing. Single-phase sensing with voltage taps. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Static accuracy is measured on a resistive load at constant frequency. Real loads and real governors are neither, so treat the figure as a comparison between boards rather than a promise.
Power stage and field drive. Power input From the main stator, 50 / 60 Hz, output 63 Vdc class. Field current rating 4 A class, forcing capability Short-term forcing current available for load steps, field resistance window 15 ohm. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Counterfeit regulators are a real problem on the widely copied boards. Buy from a source that will state where the board was made.
Accuracy and response. +/-1.0 per cent steady-state accuracy, Standard analogue response, thermal drift Low thermal drift. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. An alternator that has been rewound needs its field resistance re-measured, because a rewind commonly moves it by ten to twenty per cent in either direction.
Frequency behaviour. Rated for 50 / 60 Hz, with Not published for this model - ask us for the nameplate data. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. A regulator is a closed loop with a slow plant attached, and the plant is a large inductance. That is why the stability adjustment exists and why it is set after, not before, the voltage is correct.
Paralleling. Reactive droop via CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. The most common cause of intermittent excitation loss is a crimp terminal that was never properly made. Wiggle the harness with the machine running before replacing anything.
Protection built into the regulator. Over-excitation shutdown. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. The most common cause of intermittent excitation loss is a crimp terminal that was never properly made. Wiggle the harness with the machine running before replacing anything.
What it fits. Markon and Newage BL series alternators. Lifecycle status: Legacy, conversion to a current board recommended. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. The most common cause of intermittent excitation loss is a crimp terminal that was never properly made. Wiggle the harness with the machine running before replacing anything.
Field notes on this model. This is the Markon stamped-frame regulator used on the older BL series alternators. It is a small analogue board and it is increasingly hard to source, which is why most of these machines are now converted to a current-production board with a matching field resistance window rather than repaired.
Parallel operation is a different animal. A single set on an island load only has to hold voltage. Two sets in parallel also have to agree about reactive load, and that agreement is made or broken by the droop circuit, not by the voltage accuracy. If a site is going to parallel, the regulator choice has to be made with the droop method in mind from the beginning, because retrofitting load sharing onto a board that was never specified for it costs more than buying the right one.
Power and sensing are not the same circuit. The power input on a 036-245 can come from a different winding from the sensing input, and on PMG machines it always does. Wire them as two separate circuits, fused separately, and label both. The single most expensive mistake on a PMG set is landing the sensing leads on the PMG supply, which gives the regulator a voltage reference that rises with speed and produces a set whose voltage tracks engine rpm.
Paralleling setup. With two sets on the bus, adjust droop until reactive load divides in proportion to machine rating, then check it again at half load. A droop setting that looks right at full load and wrong at half load is usually a CT ratio error rather than a regulator fault.
The field resistance check. Measure the exciter field with the regulator disconnected and the machine stopped, then measure again after a run. Cold resistance is what the board sees at start-up; hot resistance is what it sees at full load. The 036-245 is specified with a minimum of 15 ohm minimum, and the real question is not whether the measured value is above that figure but whether the forcing current at that resistance still reaches the level the alternator needs to recover from a load step.
Voltage low under load only. This is the classic field current limit symptom. Measure the field current at full load and compare it with the 4 A class figure for the 036-245. If the board is at its limit, either the board is too small for the alternator or the field resistance has risen. A rewind, a corroded terminal or a long cable run will all produce the same reading.
Warranty and what it covers. A one year warranty on a regulator is meaningful only if it covers a field-side failure and not just a dead-on-arrival check. Ask whether a board that fails after six months in service is replaced without argument, because that is the failure mode that actually happens.
Reading the application backwards. Most regulator problems arrive described as engine trouble. A set that hunts on load, or whose voltage sags for two seconds after a contactor closes, is usually reporting a field current limit rather than a fuel problem. On a 036-245 the first thing to check is whether the 4 A class figure is being reached on a cold morning, because field resistance rises with temperature in the opposite direction to copper and a board that is marginal at 20 degC can be comfortable at 50 degC or the other way round depending on the winding.
Field cable sizing. The field circuit carries DC at low voltage and high current, so volt drop matters more than ampacity. Size the cable so that the drop at 4 A class stays under about one volt, and torque the terminals to the manufacturer figure. A field circuit that loses half a volt in the cable is a regulator that cannot reach full forcing when the load steps.