86-0769-89610677 / 86-13553838770 | info@jinjiadongli.com
Home > MOBILE GENERATORS > 110 KW Tier 4 Perkins Generator, 100 KW Prime
Trailer Mounted Silent Generator 110 kW Perkins

110 KW Tier 4 Perkins Generator, 100 KW Prime, GPM-P110-60T4F-2SS

GPM-P110-60T4F-2SS

Status: In Stock | Brand New, 2 Years International Warranty

Volume, OEM and project pricing available on request.

📞 Get a Quote:86-13553838770
← Back to products

Specifications

SKUGPM-P110-60T4F-2SS
AvailabilityIn Stock
ConditionBrand New, 2 Years International Warranty
EPA ComplianceEPA / CARB Tier 4 Final
Standby Power (ESP)110 kW / 138 kVA
Prime Power (PRP)100 kW / 125 kVA
Voltage / Phase208 V – 480 V, 3 Phase, 4 Wire, 60 Hz, 0.8 PF
Engine MakePerkins (UK)
Engine ModelPerkins 1204J-E44TTAG2, 4-Cylinder, 4.4 L, Turbocharged, 1800 RPM, Electronic Isochronous Governor
AlternatorStamford Cummins UCI274D, 12-Lead Brushless, PMG Auxiliary Excitation, Class H / H
Voltage RegulatorElectronic AVR, ±1.0% Voltage Regulation
ControllerDeep Sea Electronics DSE7320 MKII, UL Listed
Circuit Breaker3-Pole, Set Mounted, Maximum Output Rated
Fuel Tank180 Gal (680 L), Double-Walled Steel, 110% Containment, Electronic Level Sensing with Programmable Alarms
Fuel ConsumptionApprox. 28.5 L/hr (7.5 Gal/hr) @ 100% Prime Load
Runtime Autonomy26 Hours @ 75% Load
Overall Dimensions2,610 × 1,136 × 1,919 mm (L × W × H, Standard Silent Enclosure)
Dry WeightApprox. 2,400 kg (5,290 lb) — exact weight per configuration
Sound LevelMeets & Exceeds North America Level 2 / EU 2000/14/EC; Approx. 69 dB(A) @ 7 m
TrailerD.O.T. Compliant, 7,000 lbs GVWR, Dual-Axle with Electric Brakes on All Axles
Skid Base7 GA Heavy-Duty Steel Skid with Integrated Vibration Isolators and Fuel / Coolant / Oil Drain Extensions
StandardsISO 8528-5 Class G2, NFPA 110, ISO 3046, IEC 60034-1:2017, NEMA MG1, NEC 700/701/702

Product Overview

GPM-P110-60T4F 110 kW Perkins Generator Perkins’ 110 kW Mobile Generator delivers dependable performance for both prime and mobile power applications. Powered by a UK made Perkins engine, this generator is 100% engineered, assembled, and tested to meet the highest industry standards. Specifications: Power Output: 110 kW / 138 kVA Standby, 100 kW / 125 kVA Prime Voltage & Frequency: 208V to 480V, 60Hz Engine: Perkins 1204J-E44TTAG2, 1800 RPM, EPA CARB Tier 4 Final Alternator: Stamford UCI274D with PMG (Permanent Magnet Generator) Controller: Deep Sea DSE7320MKII, UL listed Fuel Tank: 26 hours runtime @ 75% load Warranty: 2 years or 2,000 hours international coverage Industrial-Grade Components for Superior Durability At the core of this unit is the Perkins 1204J-E44TTAG2 engine, an EPA Tier 4 Final compliant, turbocharged workhorse designed for efficiency and worldwide service support. Paired with a Stamford alternator, featuring PMG auxiliary excitation, the generator ensures stable voltage output and clean waveform performance even during sustained short circuit. An advanced Deep Sea Electronics DSE7320 MKII controller provides intuitive operation and monitoring with manual, auto, and remote start/stop functions. Built-In Fuel Tank and Skid Assembly for Daily Operation This generator includes a 180-gallon, double-walled steel fuel tank, offering up to 26 hours of runtime at 75% load. Electronic fuel level sensing, programmable alarms, and visual gauges provide convenience and safety. The entire assembly is mounted on a 7-gauge heavy-duty steel skid with integrated vibration isolators and fuel/coolant/oil drain extensions. Certified Performance and Global Warranty Coverage This unit is designed to meet NFPA 110, ISO 8528-5 Class G-2, and other key international standards. Every unit is individually load-tested at the factory and covered by an international 2-year/2,000-hour warranty. Whether for stationary emergency, stationary prime, or mobile prime use, this gener

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com

Jinjia Power, Quality Assured

Frequently Asked Questions

What are the standby and prime ratings of the 110 KW Tier 4 Perkins Generator?

The 110 KW Tier 4 Perkins Generator delivers 110 kW / 138 kVA standby, and 100 kW / 125 kVA prime per ISO 8528 duty definitions. Standby rating applies to emergency use under varying load; prime rating applies to continuous operation under a steady load.

What voltage and phase configuration does the 110 KW Tier 4 Perkins Generator output?

The 110 KW Tier 4 Perkins Generator is configured for 208 V – 480 V, 3 Phase, 4 Wire, 60 Hz, 0.8 PF. Confirm the required voltage and phase before ordering, since the reconnectable alternator is set at the factory.

Which engine drives the 110 KW Tier 4 Perkins Generator?

The 110 KW Tier 4 Perkins Generator is powered by Perkins (UK), model Perkins 1204J-E44TTAG2, 4-Cylinder, 4.4 L, Turbocharged, 1800 RPM, Electronic Isochronous Governor.

What alternator is fitted to the 110 KW Tier 4 Perkins Generator?

The 110 KW Tier 4 Perkins Generator uses Stamford Cummins UCI274D, 12-Lead Brushless, PMG Auxiliary Excitation, Class H / H. The alternator is matched to the engine output with margin for transient loads.

How is voltage regulated on the 110 KW Tier 4 Perkins Generator?

Voltage on the 110 KW Tier 4 Perkins Generator is held by Electronic AVR, ±1.0% Voltage Regulation, which keeps output steady as load steps on and off.

What controller does the 110 KW Tier 4 Perkins Generator use?

The 110 KW Tier 4 Perkins Generator is controlled by Deep Sea Electronics DSE7320 MKII, UL Listed. The controller handles start, stop, protection shutdowns and mains failure changeover when an ATS is fitted.

What circuit breaker is supplied with the 110 KW Tier 4 Perkins Generator?

The 110 KW Tier 4 Perkins Generator is fitted with 3-Pole, Set Mounted, Maximum Output Rated. Breaker rating is matched to the set output so the generator is protected against overload and short circuit.

How much fuel does the 110 KW Tier 4 Perkins Generator carry?

The 110 KW Tier 4 Perkins Generator has 180 Gal (680 L), Double-Walled Steel, 110% Containment, Electronic Level Sensing with Programmable Alarms. Confirm the base tank meets your local containment rules before siting the set.

What is the fuel consumption of the 110 KW Tier 4 Perkins Generator?

Fuel consumption on the 110 KW Tier 4 Perkins Generator is Approx. 28.5 L/hr (7.5 Gal/hr) @ 100% Prime Load. Consumption rises with load, so size the tank against your expected duty cycle rather than the headline figure.

How long can the 110 KW Tier 4 Perkins Generator run on a full tank?

The 110 KW Tier 4 Perkins Generator runs for 26 Hours @ 75% Load. For longer outages, plan a bulk fuel supply or a refuelling schedule alongside the set.

What are the dimensions and weight of the 110 KW Tier 4 Perkins Generator?

Dimensions: 2,610 × 1,136 × 1,919 mm (L × W × H, Standard Silent Enclosure). Dry weight: Approx. 2,400 kg (5,290 lb) — exact weight per configuration. Check access routes, crane capacity and floor loading before delivery.

How loud is the 110 KW Tier 4 Perkins Generator?

Sound level on the 110 KW Tier 4 Perkins Generator is Meets & Exceeds North America Level 2 / EU 2000/14/EC; Approx. 69 dB(A) @ 7 m. Site the set away from noise-sensitive boundaries and check local limits before installation.

Is the 110 KW Tier 4 Perkins Generator available as a trailer mounted unit?

The 110 KW Tier 4 Perkins Generator can be supplied trailer mounted: D.O.T. Compliant, 7,000 lbs GVWR, Dual-Axle with Electric Brakes on All Axles. Trailer configuration is normally chosen for rental fleets and site work where the set moves between locations.

What emission and standards compliance does the 110 KW Tier 4 Perkins Generator carry?

Emission compliance: EPA / CARB Tier 4 Final. Design standards: ISO 8528-5 Class G2, NFPA 110, ISO 3046, IEC 60034-1:2017, NEMA MG1, NEC 700/701/702.

What is the availability and warranty on the 110 KW Tier 4 Perkins Generator?

The 110 KW Tier 4 Perkins Generator is currently In Stock. Condition: Brand New, 2 Years International Warranty. Request the current datasheet and test report with your quotation.

What applications suit the 110 KW Tier 4 Perkins Generator?

The 110 KW Tier 4 Perkins Generator suits standby duty for commercial buildings, industrial plant, telecom sites and rental fleets where a compact, trailer-mountable set is required. Load type and starting current determine the final rating choice.