Home > Diesel Generators > BCY18-60 - Yanmar | 18 kW 23 kVA
Yanmar | 18 kW 23 kVA Diesel Generator | Model BCY18-60 | Jinjia Power

BCY18-60 - Yanmar | 18 kW 23 kVA

Yanmar

Model: BCY18-60

Power: 18KW 23KVA Standby / 18KW 23KVA Prime

Status: Brand New, 2 Years International Warranty

Volume, OEM and project pricing available on request.

📞 Get a Quote:86-13553838770
← ← Back to Products

Product Specifications

ModelBCY18-60
BrandYanmar
SeriesBCY series (Yanmar water-cooled diesel)
Standby Output18 kW / 23 kVA (ESP)
Prime Output16 kW / 20 kVA (PRP)
Power Factor0.78
Phase / ConnectionThree phase, 4-wire (star)
Voltage480 V
Frequency60 Hz
Rated Speed1800 rpm
Current @ Standby27.7 A per line
Current @ Prime24.3 A per line
EngineYanmar diesel, 1800 rpm
Fuel TypeDiesel, EN 590 / ASTM D975 grade
Fuel Consumption @ 100%5.6 L/h (0.31 L/kWh)
Fuel Consumption @ 75%4.5 L/h
Fuel Consumption @ 50%3.8 L/h
Fuel TankBase-frame tank, typically 50-100 L depending on build
Runtime @ 75% Load11 hours on a 50 L base tank
AlternatorBrushless synchronous, 4-pole, single bearing, direct coupled
Insulation / EnclosureClass H insulation, IP23 protection
Voltage RegulationAVR, +/- 1% steady state, THD < 3%
ControllerAutomatic panel, manual/auto selector, LCD metering, RS485 Modbus
ProtectionOver-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence
Starting System12 V DC electric starter, 12 V charge alternator, battery included
CoolingRadiator cooled, 40 C ambient design
DimensionsOpen skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation.
Dry WeightOpen skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation.
Noise LevelSoundproofed version typically 68-72 dB(A) @ 1 m
Enclosure OptionsOpen skid / weatherproof silent canopy / containerised / mobile trailer
EmissionEmission tier depends on the destination market and is confirmed per order — EU Stage V, US EPA Tier 4 Final, or unregulated where the market allows.
StandardISO 8528-1, performance class G1/G2; CE marking supported by the manufacturing plant's Declaration of Conformity
Warranty2 years or 2,000 hours, international coverage
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 2 Years International Warranty
QualityLoad bank tested in our Dongguan facility
ReliabilityMade in China; factory load-bank tested

Overview

BCY18-60 at a glance. This is a 18 kW / 23 kVA standby, 16 kW / 20 kVA prime diesel generating set built on a Yanmar platform and wound for 480 V, 60 Hz three phase output at 1800 rpm. It sits in the small stationary class where the set is bought to carry a defined load block rather than to run a plant: a shop, a guesthouse, a telecom cabinet, a small cold store, a farm pump, or the essential circuit of a house. At this rating the physical size matters as much as the numbers, which is why the same machine is offered on an open skid and inside a canopy that fits through a standard doorway.

Reading the model code. BCY18-60 follows the Yanmar BCY convention: BCY is the water-cooled diesel generator family, the two digits are the kW class, -60 means a 60 Hz build, SP marks the soundproofed single-phase version, T4 marks Tier 4 Final emission hardware and a leading A marks the complete package with AVR and control panel rather than a bare engine. Reading it that way, BCY18-60 is a 18 kW three phase machine at 60 Hz.

Why the kVA is bigger than the kW. This is a three-phase set rated at 0.8 power factor, so 18 kW standby corresponds to 23 kVA and the two figures differ by exactly the reactive component the alternator has to carry. Quoting only the kW understates the copper and the switchgear: cables, breaker and busbar all size on the 23 kVA and the 27.7 A line current, while the engine only ever sees the 18 kW. That split is the most common source of undersized installations on three-phase sets in this class.

Standby and prime are two different machines in one frame. ISO 8528 defines standby (ESP) as the maximum a set may deliver for up to 200 hours a year on a varying load, with no overload capability, and prime (PRP) as the continuous rating under a varying load for unlimited hours with a 10 per cent overload window. This set is 18 kW / 23 kVA standby and 16 kW / 20 kVA prime, so the gap between the two, 2.2 kW, is the margin the engine keeps for overload and for altitude and temperature derating. If the load runs for days rather than hours, quote against prime and treat the standby figure as a peak that must not be sustained.

What the nameplate means once it is wired in. At 23 kVA this set pushes 27.7 A down each line on a 480 V three-phase supply, and 24.3 A at the prime rating. Those currents, not the kVA figure, are what the switchgear and the cable have to survive: the outgoing breaker should be a 40 A frame device set to trip above 30.4 A, and the run from the alternator terminals to the first panel should be 10 mm2 copper per phase for a normal 20 to 30 m span. On a single-phase set the same current sits on two conductors instead of three, so the cable is heavier for the same kVA, which is the hidden cost of going monophase above about 15 kVA.

The engine behind the badge. Yanmar builds the whole package rather than buying an engine in, which is why the BCY sets are unusually compact for their output. The TNV-series water-cooled diesels used in this class are indirect-injection, mechanically governed units built for continuous duty in marine and agricultural service, and the same basic engine is sold into small boats, refrigeration units and construction equipment. The practical benefit is parts: Yanmar's dealer network is denser than any generator brand's in most export markets.

Emissions. The set is offered in the emission configuration that suits the destination market. The export-tier build has no after-treatment and is the simplest to maintain; the Tier 4 Final build adds a DOC and DPF and is the only version that can be sold into the United States and Canada. Confirm the destination before fixing the engine variant, because the two builds are not interchangeable after the fact.

On the emission marking. This model code carries no trailing emission suffix, which means the set is built to whatever calibration the destination market requires rather than to a fixed stage. In practice that is an advantage at the quotation stage, because the same frame can be ordered as an export-tier build for markets with loose import rules or as a Tier 4 Final build where the rules are tight, without changing the electrical data, the alternator or the canopy. What it does mean is that the engine variant has to be fixed in writing before the order is placed. A set delivered as an export build cannot be upgraded to Tier 4 Final afterwards; the after-treatment is designed into the exhaust and the engine calibration is locked. Confirm the destination country and the certification the buyer needs, then pin the engine variant on the order.

The alternator end. The machine is a brushless, four-pole, single-bearing alternator direct-coupled to the engine flywheel housing, insulated to class H and protected to IP23. Regulation is by AVR at plus or minus one per cent steady state with total harmonic distortion under three per cent, which is clean enough for a UPS input but not clean enough to skip a filter in front of a sensitive analyser. Single bearing means the alternator has no bearing of its own on the drive end: it relies on the engine flywheel, which is why alignment and flywheel housing condition matter at every overhaul.

Control and protection. The standard panel gives manual and automatic modes, LCD metering of phase voltage, line current, kW, pf, kWh and engine oil pressure, coolant temperature and fuel level, plus a Modbus RTU port on RS485 for a building management system. Protection covers over-speed, low oil pressure, high coolant temperature, over and under voltage, over and under frequency, over-current and phase sequence, with the last twelve events held in a rolling log. That event log is the single most useful diagnostic on the machine: when a set trips at three in the morning, the log tells you which of the eight protections opened first.

Canopy and noise. The open skid build is the machine on a base frame with the radiator exposed, suitable for a plant room or a covered compound. The soundproofed canopy drops the one-metre level to roughly 68 to 72 dB(A) and is the version most export buyers take, because it also weatherproofs the set and lets it stand outdoors. Containerised and trailer-mounted builds use the same core machine with a different envelope, so the electrical data on this page holds across all four.

Fuel and runtime. At full load the engine burns about 5.6 L/h, at 75 per cent about 4.5 L/h and at half load about 3.8 L/h. The litres-per-kWh figure is worst at part load (0.42 L/kWh at half load against 0.31 at full load), which is the counter-intuitive part of sizing: a set run at half load burns more fuel per unit delivered than the same set run hard. On a 50 L base-frame tank that works out to roughly 11 hours at 75 per cent load, and on a 100 L tank roughly double. For anything above eight hours of continuous running, plan a bulk tank with a day tank and a transfer pump rather than relying on the base frame.

Where this rating actually fits. A 18 kW three-phase set is the entry point for light industrial and commercial standby: a workshop with a few machines, a cold store, a small hotel, a telecom site, a water treatment pump set. Three phase at this rating means motors start properly and the cable is a third of the copper of the single-phase equivalent. The constraint is balance: keep the phase-to-phase imbalance under 20 per cent, because an unbalanced load derates the alternator faster than an overload does.

Parallel operation and transfer. Below about 30 kVA, paralleling is rarely worth the control complexity: two sets need load-sharing governors, synchronising hardware and a common switchgear panel, and the cost of that exceeds the cost of simply buying one larger set. What this rating does need is a proper transfer arrangement: a manual changeover switch if the site is attended, an automatic transfer switch with a mains-failure sensor if it is not. The set itself accepts a remote start signal on a two-wire dry contact, which is all an ATS needs.

Maintenance that actually gets done. Oil and oil filter at 250 hours or annually, whichever comes first; fuel filter and air filter at 500 hours; coolant condition checked annually and changed at two years; valve clearance checked at 1,000 hours. The item most often skipped is the load bank test: a set that runs monthly on a light load will wet-stack and glaze the bores, and the first time it sees a real load it will smoke and under-perform. Run it at 75 per cent load for an hour every quarter, and record the exhaust temperature, because that is the number that tells you the engine is healthy.

Sizing it against a cold store. A cold store is the classic case where the load is almost entirely motor starting. The compressors are hermetic or semi-hermetic, they start against head pressure unless the system has a pump-down cycle, and each start can pull five times running current for half a second. On a 23 kVA set the practical limit is one compressor starting at a time with the evaporator fans already running, which is about 11.2 kW of steady load plus the start. If the store has two compressors that can start together, either interlock them or move up a frame. The other factor is the duty: a cold store runs the set for hours, not minutes, so quote against the prime rating of 16 kW rather than the standby figure, and check that the fuel tank gives the runtime the store needs to reach the next delivery.

Fire separation and housekeeping. A diesel set is a stored-fuel appliance and should be treated as one. Keep the set clear of combustible storage, keep the exhaust at least a metre from anything that can burn, and fit a fuel shut-off that can be reached without walking past the machine. In a plant room, the wall between the set and the occupied space should be fire-rated and the door self-closing. The housekeeping item that matters most is dust: a set that sits in a dusty environment clogs its air filter and its radiator fins, and both failures show up as overheating long before anyone connects them to the dust.

Fuel contamination. Diesel stored for months grows bacteria at the water interface, and the resulting sludge blocks filters and corrodes injection equipment. The signs are a filter that clogs repeatedly and a fuel that smells wrong. The prevention is a water-separating pre-filter, a tank that is drained of water at intervals, and a fuel polishing session once a year on any tank above a few hundred litres. On a set this size the injection pump is mechanical and rebuildable, which is a mercy, but a rebuild costs more than a decade of filters.

New build or a rebuilt unit. A rebuilt set is attractive on price and it can be a good buy if the rebuild was done properly: new liners, new bearings, a rewound or tested alternator, and a load bank certificate. The risk is that most rebuilds are cosmetic. The questions that separate the two are specific: what was the hours reading before the rebuild, was the injection pump calibrated, was the alternator megger-tested, and is there a load bank printout. A set that cannot answer those four questions is being sold on paint. For a standby application where the set must work first time, a new build with a two-year warranty is usually the cheaper decision over ten years.

Control panel and remote monitoring. The controller on this set provides local start and stop, manual and auto modes, metering of voltage, current, power, power factor, frequency, oil pressure, coolant temperature and fuel level, plus a rolling event log and a set of configurable protections. The remote interface is a two-wire dry contact for start, plus volt-free contacts for common alarm and shutdown, and a Modbus RTU port on RS485 for anything more detailed. That combination covers almost every building management system. What it does not cover is remote diagnosis over the internet, which needs a gateway module; if the site is unmanned, add one, because the difference between reading an alarm code remotely and sending someone to site is the difference between an hour and a day of downtime.

Where it sits in the range. Within the same Yanmar family at 60 Hz, one step down is the BCY14-60T4 at 14 kW / 18 kVA. The step between frames is a different engine displacement and a different alternator core, not a re-rated plate, so the price step is real rather than administrative.

How to order it. Quote five things together and the factory cannot get it wrong: the model (BCY18-60), the standby and prime rating, the voltage and frequency (480 V, 60 Hz), the phase (three phase), and the enclosure (open skid, soundproofed canopy, containerised or trailer). Add the emission tier if the destination is regulated. Anything else, including the controller variant, the alternator brand and the fuel tank size, is a build option rather than a different machine.

Frequently Asked Questions

What are the standby and prime ratings of the BCY18-60?

Standby output is 18 kW / 23 kVA (ESP), prime output is 16 kW / 20 kVA (PRP). The standby (ESP) figure is the maximum the set can carry for the duration of a mains failure and is not meant for continuous running. The prime (PRP) figure is what it can hold indefinitely at a varying load. Match the rating to the duty the set will actually see — running a standby-rated machine as prime voids the warranty.

What voltage and frequency does the BCY18-60 output?

The BCY18-60 is wound for 480 V, 60 Hz, three phase, 4-wire (star), running at 1800 rpm. Voltage and frequency are fixed when the set is built, so confirm the site supply before the order is released. Other voltages and both 50 Hz and 60 Hz builds are available on the same frame.

Which engine drives the BCY18-60?

The BCY18-60 is powered by a Yanmar diesel engine. Engine and alternator are matched on the test bed, so the set reaches its rating without derating.

What is the fuel consumption of the BCY18-60?

Fuel consumption is 5.6 L/h (0.31 L/kWh) at 100% load, 4.5 L/h at 75% load and 3.8 L/h at 50% load. These are measured figures on the standard build at those load points; real consumption shifts with load profile, ambient temperature and fuel quality. Send the expected daily running hours and average load if you want a duty-cycle estimate.

How long will the BCY18-60 run on a full tank?

Runtime is 11 hours on a 50 L base tank. Tank capacity can be increased on request, and runtime scales directly with it against the consumption figures above.

How loud is the BCY18-60?

Sound pressure is 68-72 dB(A) @ 1 m on the soundproofed build. An open skid set is considerably louder and needs either an acoustic canopy or a separate plant room to meet site noise limits.

What enclosure options are available for the BCY18-60?

The BCY18-60 is available as open skid, weatherproof silent canopy, containerised or mobile trailer. Enclosure choice changes footprint, weight, noise level and price, so specify it with the enquiry and the quotation will match the build.

What controller and alternator are fitted to the BCY18-60?

The BCY18-60 ships with an automatic panel, manual/auto selector, LCD metering, RS485 Modbus and a brushless synchronous, 4-pole, single bearing, direct coupled alternator. Both are build options — alternative controllers and alternator makes can be specified when the order is placed.

How stable is the voltage output of the BCY18-60?

On this set, voltage is held by an AVR, +/- 1% steady state, THD < 3% and the machine is built with Class H insulation, IP23 protection. That grade of regulation suits motors, pumps and most electronic loads; for sensitive IT or medical equipment, specify the higher-grade controller option.

What protection does the BCY18-60 have?

The controller trips on over-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence. These shutdowns stop the set before damage occurs, which is what makes an unattended standby installation safe to leave running.

What warranty comes with the BCY18-60?

Warranty is 2 years or 2,000 hours, international coverage. It applies to the set as configured — running outside the rated duty, using non-specified fuel or skipping scheduled service will void it.

How do I get a firm price for the BCY18-60?

Send the model (BCY18-60), the duty (standby or prime), voltage and frequency, phase, and the enclosure type you need. Jinjia Power quotes against a confirmed configuration rather than a list price, so the figure you receive matches the machine that ships. Typical lead time is 20–30 days for units up to 1000 kW and 30–45 days above that.