Model: K16UM IV
Power: 14.5KW 14.5KVA Standby / 13.2KW 13.2KVA Prime
Status: Brand New, 2 Years International Warranty
Volume, OEM and project pricing available on request.
| Model | K16UM IV |
| Brand | KOHLER |
| Series | K series (stationary, value) |
| Standby Output | 16 kW / 16 kVA (ESP) |
| Prime Output | 15 kW / 15 kVA (PRP) |
| Power Factor | 1.00 |
| Phase / Connection | Single phase, 2-wire |
| Voltage | 230 V |
| Frequency | 50 Hz |
| Rated Speed | 1500 rpm |
| Current @ Standby | 69.6 A |
| Current @ Prime | 65.2 A |
| Engine | Kohler-SDMO diesel, 1500 rpm |
| Fuel Type | Diesel, EN 590 / ASTM D975 grade |
| Fuel Consumption @ 100% | 5.0 L/h (0.31 L/kWh) |
| Fuel Consumption @ 75% | 4.0 L/h |
| Fuel Consumption @ 50% | 3.4 L/h |
| Fuel Tank | Base-frame tank, typically 50-100 L depending on build |
| Runtime @ 75% Load | 13 hours on a 50 L base tank |
| Alternator | Brushless synchronous, 4-pole, single bearing, direct coupled |
| Insulation / Enclosure | Class H insulation, IP23 protection |
| Voltage Regulation | AVR, +/- 1% steady state, THD < 3% |
| Controller | Automatic panel, manual/auto selector, LCD metering, RS485 Modbus |
| Protection | Over-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence |
| Starting System | 12 V DC electric starter, 12 V charge alternator, battery included |
| Cooling | Radiator cooled, 40 C ambient design |
| Dimensions | Open skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation. |
| Dry Weight | Open skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation. |
| Noise Level | Soundproofed version typically 68-72 dB(A) @ 1 m |
| Enclosure Options | Open skid / weatherproof silent canopy / containerised / mobile trailer |
| Emission | Emission tier depends on the destination market and is confirmed per order — EU Stage V, US EPA Tier 4 Final, or unregulated where the market allows. |
| Standard | ISO 8528-1, performance class G1/G2; CE marking supported by the manufacturing plant's Declaration of Conformity |
| Warranty | 2 years or 2,000 hours, international coverage |
| Availability | IN STOCK, Same day shipping Worldwide available |
| Condition | Brand New, 2 Years International Warranty |
| Quality | Load bank tested in our Dongguan facility |
| Reliability | Made in China; factory load-bank tested |
K16UM IV at a glance. This is a 16 kW / 16 kVA standby, 15 kW / 15 kVA prime diesel generating set built on a Kohler-SDMO platform and wound for 230 V, 50 Hz single phase output at 1500 rpm. It sits in the small stationary class where the set is bought to carry a defined load block rather than to run a plant: a shop, a guesthouse, a telecom cabinet, a small cold store, a farm pump, or the essential circuit of a house. At this rating the physical size matters as much as the numbers, which is why the same machine is offered on an open skid and inside a canopy that fits through a standard doorway.
Reading the model code. K16UM IV decodes as the K prefix, the frame number 16 which tracks the kVA class, and the suffix string UM. The K range shares the same Mitsubishi industrial base as the T range, with the same mechanical governor and 22:1 compression ratio, but is trimmed for a lower price point on the smaller ratings. In this case the M suffix marks the monophase build; the U marks the uprated frame, which is why the same number appears with a higher kVA in the U version; the trailing IV is the emission stage of the engine fitted, not a different alternator. The frame number is a direct read of the rating: 16 in the code, 16 kVA on the plate, so the label and the data agree.
Why kW and kVA are the same number here. On a single-phase set the alternator is wound and rated at unity power factor, so 16 kW and 16 kVA describe the same load and the ratio is 1.00. That is not marketing rounding: it means the machine delivers its full 16 kW into a resistive or lightly inductive load without the alternator being the limit. The moment a motor is hung on it the power factor drops and the usable kW falls below the kVA, so a 16 kVA single-phase set driving a 0.8 pf load gives about 13 kW, not 16. Size single-phase sets on motor starting kVA, never on the kW figure alone.
Standby and prime are two different machines in one frame. ISO 8528 defines standby (ESP) as the maximum a set may deliver for up to 200 hours a year on a varying load, with no overload capability, and prime (PRP) as the continuous rating under a varying load for unlimited hours with a 10 per cent overload window. This set is 16 kW / 16 kVA standby and 15 kW / 15 kVA prime, so the gap between the two, 1.0 kW, is the margin the engine keeps for overload and for altitude and temperature derating. If the load runs for days rather than hours, quote against prime and treat the standby figure as a peak that must not be sustained.
What the nameplate means once it is wired in. At 16 kVA this set pushes 69.6 A down each line on a 230 V single-phase supply, and 65.2 A at the prime rating. Those currents, not the kVA figure, are what the switchgear and the cable have to survive: the outgoing breaker should be a 100 A frame device set to trip above 76.5 A, and the run from the alternator terminals to the first panel should be 25 mm2 copper per phase for a normal 20 to 30 m span. On a single-phase set the same current sits on two conductors instead of three, so the cable is heavier for the same kVA, which is the hidden cost of going monophase above about 15 kVA.
The engine behind the badge. SDMO is engine-agnostic by design and picks the diesel per frame. On the T and K ranges in this class that engine is Mitsubishi: the S3L2-SD three-cylinder at 1.32 L on the smaller units and the S4L2-SD four-cylinder at 1.50 L as the rating climbs, both naturally aspirated, mechanically governed and running a 22:1 compression ratio. Mechanical governing is the point: it holds frequency without an electronic map, which is what makes these sets tolerant of dirty fuel and of long periods between runs. The trade is that the fuel curve is fixed, so light-load fuel economy is worse than a common-rail engine of the same output.
Who actually owns SDMO now. Kohler bought SDMO in 2005 and the product has been Kohler-SDMO since; Kohler itself moved to Platinum Equity in 2024. In practice that means the set you buy today is a French-designed package (Brest is the main plant, with assembly also in Spain, India and Brazil) carrying a Kohler controller and a Kohler-owned warranty chain. It also means the K-prefix and T-prefix frames share the same alternator tooling, so a K9 and a T9KM differ mainly in winding and canopy rather than in core hardware.
Emissions. The IV suffix marks the engine emission stage. On this frame that is an export-tier build: it is not EPA certified for the United States or Canada and is sold for markets that follow the older Stage IIIA / Tier 3 limits. Mechanically it is the simpler machine, with no after-treatment in the exhaust, which is why it is cheaper and why it tolerates long idle periods better than a Tier 4 Final set. If the destination is North America, quote the T4F or T4i version instead.
What the IV build actually is. The trailing IV on K16UM IV is the emission stage of the engine, not a different alternator or a different frame. On this platform IV marks the export-tier calibration: the engine is built to the older Stage IIIA equivalent limits, it carries no diesel particulate filter and no diesel oxidation catalyst, and it is therefore not certified for sale into the United States or Canada. That single fact drives most of the practical differences a buyer feels. There is no after-treatment to load up, so the set tolerates short runs and long idle periods without the exhaust back-pressure penalty that a Tier 4 Final machine suffers. There is no regeneration cycle to interrupt, so nothing on the set will suddenly command a higher load while it burns off soot. There is also no after-treatment service interval, which means the maintenance bill over ten years is essentially oil, filters and coolant. The trade is regulatory: if the destination is a regulated market, this exact machine cannot be shipped there, and no amount of paperwork changes that. The sibling II build of the same frame sits on the other side of that line.
The alternator end. The machine is a brushless, four-pole, single-bearing alternator direct-coupled to the engine flywheel housing, insulated to class H and protected to IP23. Regulation is by AVR at plus or minus one per cent steady state with total harmonic distortion under three per cent, which is clean enough for a UPS input but not clean enough to skip a filter in front of a sensitive analyser. Single bearing means the alternator has no bearing of its own on the drive end: it relies on the engine flywheel, which is why alignment and flywheel housing condition matter at every overhaul.
Control and protection. The standard panel gives manual and automatic modes, LCD metering of phase voltage, line current, kW, pf, kWh and engine oil pressure, coolant temperature and fuel level, plus a Modbus RTU port on RS485 for a building management system. Protection covers over-speed, low oil pressure, high coolant temperature, over and under voltage, over and under frequency, over-current and phase sequence, with the last twelve events held in a rolling log. That event log is the single most useful diagnostic on the machine: when a set trips at three in the morning, the log tells you which of the eight protections opened first.
Canopy and noise. The open skid version is the bare machine on a steel base frame with the radiator exposed; it is the cheapest and the easiest to service but it is loud enough that it cannot sit next to a neighbour's fence. The soundproofed canopy version adds a lined enclosure with a residential-grade silencer and takes the level at one metre down to roughly 68 to 72 dB(A), which is normal conversation at arm's length. For a single-phase set sitting beside a house, the canopy is not optional: the extra cost buys the planning permission.
Fuel and runtime. At full load the engine burns about 5.0 L/h, at 75 per cent about 4.0 L/h and at half load about 3.4 L/h. The litres-per-kWh figure is worst at part load (0.42 L/kWh at half load against 0.31 at full load), which is the counter-intuitive part of sizing: a set run at half load burns more fuel per unit delivered than the same set run hard. On a 50 L base-frame tank that works out to roughly 13 hours at 75 per cent load, and on a 100 L tank roughly double. For anything above eight hours of continuous running, plan a bulk tank with a day tank and a transfer pump rather than relying on the base frame.
Where this rating actually fits. A 16 kW single-phase set is the standard answer for a house, a small guesthouse, a shop, a clinic or a farm where the load is lights, fridges, air conditioning, a pump and a handful of tools. The limit is motor starting: a 2.2 kW borehole pump pulls five to six times its running current for a second, and a 16 kVA set will take that only if nothing else is on line at the same moment. Sequence the loads, or fit a soft starter, and the set behaves; put everything on at once and it stalls.
Parallel operation and transfer. Below about 30 kVA, paralleling is rarely worth the control complexity: two sets need load-sharing governors, synchronising hardware and a common switchgear panel, and the cost of that exceeds the cost of simply buying one larger set. What this rating does need is a proper transfer arrangement: a manual changeover switch if the site is attended, an automatic transfer switch with a mains-failure sensor if it is not. The set itself accepts a remote start signal on a two-wire dry contact, which is all an ATS needs.
Maintenance that actually gets done. Oil and oil filter at 250 hours or annually, whichever comes first; fuel filter and air filter at 500 hours; coolant condition checked annually and changed at two years; valve clearance checked at 1,000 hours. The item most often skipped is the load bank test: a set that runs monthly on a light load will wet-stack and glaze the bores, and the first time it sees a real load it will smoke and under-perform. Run it at 75 per cent load for an hour every quarter, and record the exhaust temperature, because that is the number that tells you the engine is healthy.
Sizing it against a clinic or small medical facility. A clinic is the case where the load is small but the consequence of a failure is not, so redundancy matters more than headroom. A 16 kVA set covers lights, refrigeration for vaccines, a steriliser, diagnostic equipment and the air conditioning for one or two rooms, and it will do it at well under half load, which is exactly where a diesel set is least happy. The answer is not a smaller set but a load that is switched in deliberately: bring the air conditioning on only after the essential circuits have stabilised, and run the set at above fifty per cent for a block of time each week. Sensitive diagnostic equipment also wants the AVR to hold within one per cent, which the standard alternator on this set does.
Fuel system and day tank. The base-frame tank on a set this size is a day tank, not a storage tank. If the set runs for more than a shift, feed it from a bulk tank through a transfer pump with a level switch, and put a water-separating pre-filter between the bulk tank and the day tank rather than relying on the engine filter alone. Slope the supply line so it cannot trap air, fit a manual shut-off at the tank, and make sure the return line goes back to the tank rather than being blanked, because the injection pump on a mechanical engine needs the return path for cooling. Never fill a hot tank immediately after a long run; let it settle.
Loose connections and the heat they make. A terminal that is not tight has resistance, resistance makes heat, and heat eventually makes a failure. At 69.6 A the main output terminals are carrying enough current to melt a poorly made joint. Check the torque on the alternator terminals, the breaker lugs and the earth stud at every annual service, and look for discoloured insulation, which is the evidence of a joint that has been running hot. This is a fifteen-minute job that prevents the most expensive class of failure on the machine, because a burnt terminal usually takes the alternator with it.
What the warranty should actually cover. A two-year international warranty is only worth what the local support is worth. Before ordering, confirm three things: who performs warranty work in the destination country, whether the warranty covers parts only or parts and labour, and what the response time is. A warranty that requires the failed part to be shipped back to the factory before a replacement is issued is a warranty that costs the customer a month of downtime. The other clause to read is the exclusion for ''misuse'', which some warranties interpret to include running below the recommended load, so check that a light-load application does not void coverage.
Lubrication and oil analysis. The engine carries a full-flow oil filter and a sump of a few litres, and the service interval is 250 hours or annually, whichever comes first. The annual clause matters more than the hours on a standby set, because oil that sits in a sump for a year absorbs moisture and its additive package depletes regardless of run time. Beyond the interval, oil analysis is the cheapest diagnostic available: a sample at each service shows fuel dilution, which is the signature of wet stacking; coolant, which points at a head gasket or a liner seal; and wear metals, which track bearing and ring condition. A single sample is a snapshot; a trend over four services tells you whether the engine is healthy, and it costs less than the oil.
Where it sits in the range. Within the same Kohler-SDMO, K monophase family at 50 Hz , one step down is the K12UM II at 12 kW / 12 kVA, and one step up is the K17M IV at 17 kW / 17 kVA. The step between frames is a different engine displacement and a different alternator core, not a re-rated plate, so the price step is real rather than administrative.
How to order it. Quote five things together and the factory cannot get it wrong: the model (K16UM IV), the standby and prime rating, the voltage and frequency (230 V, 50 Hz), the phase (single phase), and the enclosure (open skid, soundproofed canopy, containerised or trailer). Add the emission tier if the destination is regulated. Anything else, including the controller variant, the alternator brand and the fuel tank size, is a build option rather than a different machine.
Standby output is 16 kW / 16 kVA (ESP), prime output is 15 kW / 15 kVA (PRP). The standby (ESP) figure is the maximum the set can carry for the duration of a mains failure and is not meant for continuous running. The prime (PRP) figure is what it can hold indefinitely at a varying load. Match the rating to the duty the set will actually see — running a standby-rated machine as prime voids the warranty.
The K16UM IV is wound for 230 V, 50 Hz, single phase, 2-wire, running at 1500 rpm. Voltage and frequency are fixed when the set is built, so confirm the site supply before the order is released. Other voltages and both 50 Hz and 60 Hz builds are available on the same frame.
The K16UM IV is powered by a Kohler-SDMO diesel engine. Engine and alternator are matched on the test bed, so the set reaches its rating without derating.
Fuel consumption is 5.0 L/h (0.31 L/kWh) at 100% load, 4.0 L/h at 75% load and 3.4 L/h at 50% load. These are measured figures on the standard build at those load points; real consumption shifts with load profile, ambient temperature and fuel quality. Send the expected daily running hours and average load if you want a duty-cycle estimate.
Runtime is 13 hours on a 50 L base tank. Tank capacity can be increased on request, and runtime scales directly with it against the consumption figures above.
Sound pressure is 68-72 dB(A) @ 1 m on the soundproofed build. An open skid set is considerably louder and needs either an acoustic canopy or a separate plant room to meet site noise limits.
The K16UM IV is available as open skid, weatherproof silent canopy, containerised or mobile trailer. Enclosure choice changes footprint, weight, noise level and price, so specify it with the enquiry and the quotation will match the build.
The K16UM IV ships with an automatic panel, manual/auto selector, LCD metering, RS485 Modbus and a brushless synchronous, 4-pole, single bearing, direct coupled alternator. Both are build options — alternative controllers and alternator makes can be specified when the order is placed.
On this set, voltage is held by an AVR, +/- 1% steady state, THD < 3% and the machine is built with Class H insulation, IP23 protection. That grade of regulation suits motors, pumps and most electronic loads; for sensitive IT or medical equipment, specify the higher-grade controller option.
The controller trips on over-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence. These shutdowns stop the set before damage occurs, which is what makes an unattended standby installation safe to leave running.
Warranty is 2 years or 2,000 hours, international coverage. It applies to the set as configured — running outside the rated duty, using non-specified fuel or skipping scheduled service will void it.
Send the model (K16UM IV), the duty (standby or prime), voltage and frequency, phase, and the enclosure type you need. Jinjia Power quotes against a confirmed configuration rather than a list price, so the figure you receive matches the machine that ships. Typical lead time is 20–30 days for units up to 1000 kW and 30–45 days above that.