Perkins | 15 kW Diesel Generator | Model 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE | Jinjia Power

15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE

Perkins

Model: GP-P15-60T4F-3PHASE

Power: 15 KW 19 KVA Standby / 15 KW 19 KVA Prime

Status: Brand New, 2 Year Warranty

Volume, OEM and project pricing available on request.

📞 Get a Quote:86-13553838770
← ← Back to Products

Product Specifications

Model15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE
BrandPerkins
Standby Output15 kW / 19 kVA (ESP)
Prime OutputOn request — ESP rating shown above
Power Factor0.79
Phase / ConnectionThree phase, 4-wire (star)
Voltage480 V
Frequency60 Hz
Rated Speed1800 rpm
Current @ Standby22.9 A per line
Current @ PrimeOn request
EnginePerkins diesel, 1800 rpm
Fuel TypeDiesel, EN 590 / ASTM D975 grade
Fuel TankBase-frame tank, typically 50-100 L depending on build
AlternatorBrushless synchronous, 4-pole, single bearing, direct coupled
Insulation / EnclosureClass H insulation, IP23 protection
Voltage RegulationAVR, +/- 1% steady state, THD < 3%
ControllerAutomatic panel, manual/auto selector, LCD metering, RS485 Modbus
ProtectionOver-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence
Starting System12 V DC electric starter, 12 V charge alternator, battery included
CoolingRadiator cooled, 40 C ambient design
DimensionsOpen skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation.
Dry WeightOpen skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation.
Noise LevelSoundproofed version typically 68-72 dB(A) @ 1 m
Enclosure OptionsOpen skid / weatherproof silent canopy / containerised / mobile trailer
EmissionEmission tier depends on the destination market and is confirmed per order — EU Stage V, US EPA Tier 4 Final, or unregulated where the market allows.
StandardISO 8528-1, performance class G1/G2; CE marking supported by the manufacturing plant's Declaration of Conformity
Warranty2 years or 2,000 hours, international coverage
AvailabilityIn stock, worldwide shipping
ConditionBrand New, 2 Year Warranty
QualityEngineered and assembled in China
ReliabilityLoad bank tested in China

Overview

15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE at a glance. This is a 15 kW / 19 kVA standby diesel generating set built on a Perkins platform and wound for 480 V, 60 Hz three phase output at 1800 rpm. It sits in the small stationary class where the set is bought to carry a defined load block rather than to run a plant: a shop, a guesthouse, a telecom cabinet, a small cold store, a farm pump, or the essential circuit of a house. At this rating the physical size matters as much as the numbers, which is why the same machine is offered on an open skid and inside a canopy that fits through a standard doorway.

Reading the model code. 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE is a Jinjia-built set rather than a rebadged OEM unit, so the code carries the build information directly: the prefix identifies the engine family (P for Perkins, KB for Kubota, J for John Deere, K for Kohler), the number is the kW class, 60 means 60 Hz, T4F or T4i is the emission tier, and a trailing 1PHASE or 3PHASE fixes the winding. This page is the three phase build, 15 kW / 19 kVA standby.

Why the kVA is bigger than the kW. This is a three-phase set rated at 0.8 power factor, so 15 kW standby corresponds to 19 kVA and the two figures differ by exactly the reactive component the alternator has to carry. Quoting only the kW understates the copper and the switchgear: cables, breaker and busbar all size on the 19 kVA and the 22.9 A line current, while the engine only ever sees the 15 kW. That split is the most common source of undersized installations on three-phase sets in this class.

Standby and prime are two different machines in one frame. ISO 8528 defines standby (ESP) as the maximum a set may deliver for up to 200 hours a year on a varying load, with no overload capability, and prime (PRP) as the continuous rating under a varying load for unlimited hours with a 10 per cent overload window. This set is 15 kW / 19 kVA standby. As an emergency standby set it publishes no continuous (PRP) rating; the margin the engine keeps for overload and for altitude and temperature derating is confirmed at quotation. If the load runs for days rather than hours, quote against prime and treat the standby figure as a peak that must not be sustained.

What the nameplate means once it is wired in. At 19 kVA this set pushes 22.9 A down each line on a 480 V three-phase supply; the continuous (PRP) current is confirmed at quotation. Those currents, not the kVA figure, are what the switchgear and the cable have to survive: the outgoing breaker is sized on the 22.9 A full-load current with a frame rating above that figure, and the run from the alternator terminals to the first panel is sized on the same current and on the volt drop over the actual route rather than on a standard span assumption. On a single-phase set the same current sits on two conductors instead of three, so the cable is heavier for the same kVA, which is the hidden cost of going monophase above about 15 kVA.

The engine behind the badge. Perkins supplies the 400 and 1100 series into this class, and on the Tier 4 Final builds the after-treatment package is part of the engine, not an add-on. That is why a T4F set is taller and heavier than the same output in an export-tier build: the DOC and DPF sit in the exhaust path and need their own mounting and their own service interval. Perkins parts and service are handled through the Cat dealer network worldwide, which is the main reason buyers pay the premium.

Emissions. The set is offered in the emission configuration that suits the destination market. The export-tier build has no after-treatment and is the simplest to maintain; the Tier 4 Final build adds a DOC and DPF and is the only version that can be sold into the United States and Canada. Confirm the destination before fixing the engine variant, because the two builds are not interchangeable after the fact.

On the emission marking. This model code carries no trailing emission suffix, which means the set is built to whatever calibration the destination market requires rather than to a fixed stage. In practice that is an advantage at the quotation stage, because the same frame can be ordered as an export-tier build for markets with loose import rules or as a Tier 4 Final build where the rules are tight, without changing the electrical data, the alternator or the canopy. What it does mean is that the engine variant has to be fixed in writing before the order is placed. A set delivered as an export build cannot be upgraded to Tier 4 Final afterwards; the after-treatment is designed into the exhaust and the engine calibration is locked. Confirm the destination country and the certification the buyer needs, then pin the engine variant on the order.

The alternator end. The machine is a brushless, four-pole, single-bearing alternator direct-coupled to the engine flywheel housing, insulated to class H and protected to IP23. Regulation is by AVR at plus or minus one per cent steady state with total harmonic distortion under three per cent, which is clean enough for a UPS input but not clean enough to skip a filter in front of a sensitive analyser. Single bearing means the alternator has no bearing of its own on the drive end: it relies on the engine flywheel, which is why alignment and flywheel housing condition matter at every overhaul.

Control and protection. The standard panel gives manual and automatic modes, LCD metering of phase voltage, line current, kW, pf, kWh and engine oil pressure, coolant temperature and fuel level, plus a Modbus RTU port on RS485 for a building management system. Protection covers over-speed, low oil pressure, high coolant temperature, over and under voltage, over and under frequency, over-current and phase sequence, with the last twelve events held in a rolling log. That event log is the single most useful diagnostic on the machine: when a set trips at three in the morning, the log tells you which of the eight protections opened first.

Canopy and noise. The open skid build is the machine on a base frame with the radiator exposed, suitable for a plant room or a covered compound. The soundproofed canopy drops the one-metre level to roughly 68 to 72 dB(A) and is the version most export buyers take, because it also weatherproofs the set and lets it stand outdoors. Containerised and trailer-mounted builds use the same core machine with a different envelope, so the electrical data on this page holds across all four.

Where this rating actually fits. A 15 kW three-phase set is the entry point for light industrial and commercial standby: a workshop with a few machines, a cold store, a small hotel, a telecom site, a water treatment pump set. Three phase at this rating means motors start properly and the cable is a third of the copper of the single-phase equivalent. The constraint is balance: keep the phase-to-phase imbalance under 20 per cent, because an unbalanced load derates the alternator faster than an overload does.

Parallel operation and transfer. Below about 30 kVA, paralleling is rarely worth the control complexity: two sets need load-sharing governors, synchronising hardware and a common switchgear panel, and the cost of that exceeds the cost of simply buying one larger set. What this rating does need is a proper transfer arrangement: a manual changeover switch if the site is attended, an automatic transfer switch with a mains-failure sensor if it is not. The set itself accepts a remote start signal on a two-wire dry contact, which is all an ATS needs.

Maintenance that actually gets done. Oil and oil filter at 250 hours or annually, whichever comes first; fuel filter and air filter at 500 hours; coolant condition checked annually and changed at two years; valve clearance checked at 1,000 hours. The item most often skipped is the load bank test: a set that runs monthly on a light load will wet-stack and glaze the bores, and the first time it sees a real load it will smoke and under-perform. Run it at 75 per cent load for an hour every quarter, and record the exhaust temperature, because that is the number that tells you the engine is healthy.

Sizing it against a retail shop. Retail is dominated by refrigeration and lighting, with a short but heavy surge when the compressors restart after a mains dip. A 19 kVA set carries a shop of a few hundred square metres, but the compressor restart is the deciding number: display cases that restart together can pull two to three times the steady refrigeration load for a second. Stagger the restart with a time-delay relay on each circuit and the set behaves; let them all come back at once and the set trips on over-current. The commercial point is that a shop loses its chilled stock within a few hours of an outage, so the runtime on the base tank matters as much as the rating. Work out the hours to the next delivery and size the tank to it.

Fire separation and housekeeping. A diesel set is a stored-fuel appliance and should be treated as one. Keep the set clear of combustible storage, keep the exhaust at least a metre from anything that can burn, and fit a fuel shut-off that can be reached without walking past the machine. In a plant room, the wall between the set and the occupied space should be fire-rated and the door self-closing. The housekeeping item that matters most is dust: a set that sits in a dusty environment clogs its air filter and its radiator fins, and both failures show up as overheating long before anyone connects them to the dust.

Batteries and charging. More standby failures start with a flat battery than with anything mechanical. The charging alternator on the engine keeps the battery up while the set runs, but nothing keeps it up while the set sits, and a lead-acid battery self-discharges. Fit a mains-powered float charger if the site has mains, check the electrolyte and the terminals quarterly, and replace the battery at four years whether or not it tests well, because a battery that passes a load test in the workshop can still fail at zero degrees. Keep the terminals clean and greased; a slightly corroded terminal behaves exactly like a failing starter.

Single phase or three phase, before anything else. This page is the three phase build. The two are not interchangeable: a single-phase set at unity power factor delivers its full 15 kW into a two-wire load and is the natural choice for domestic and small commercial sites, while a three-phase set delivers the same kW at a third of the current per conductor and is the only sensible choice once motors above a few kilowatts are involved. If the site has any three-phase equipment at all, the answer is three phase, even if the set is bigger than the load needs. Converting later means replacing the alternator, not rewiring the set.

Lubrication and oil analysis. The engine carries a full-flow oil filter and a sump of a few litres, and the service interval is 250 hours or annually, whichever comes first. The annual clause matters more than the hours on a standby set, because oil that sits in a sump for a year absorbs moisture and its additive package depletes regardless of run time. Beyond the interval, oil analysis is the cheapest diagnostic available: a sample at each service shows fuel dilution, which is the signature of wet stacking; coolant, which points at a head gasket or a liner seal; and wear metals, which track bearing and ring condition. A single sample is a snapshot; a trend over four services tells you whether the engine is healthy, and it costs less than the oil.

How to order it. Quote five things together and the factory cannot get it wrong: the model (15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE), the standby and prime rating, the voltage and frequency (480 V, 60 Hz), the phase (three phase), and the enclosure (open skid, soundproofed canopy, containerised or trailer). Add the emission tier if the destination is regulated. Anything else, including the controller variant, the alternator brand and the fuel tank size, is a build option rather than a different machine.

Frequently Asked Questions

What are the standby and prime ratings of the 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE?

Standby output is 15 kW / 19 kVA (ESP). This set carries an emergency standby (ESP) rating only; a continuous (PRP) rating is quoted on request. The standby (ESP) figure is the maximum the set can carry for the duration of a mains failure and is not meant for continuous running. The prime (PRP) figure is what it can hold indefinitely at a varying load. Match the rating to the duty the set will actually see — running a standby-rated machine as prime voids the warranty.

What voltage and frequency does the 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE output?

The 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE is wound for 480 V, 60 Hz, three phase, 4-wire (star), running at 1800 rpm. Voltage and frequency are fixed when the set is built, so confirm the site supply before the order is released. Other voltages and both 50 Hz and 60 Hz builds are available on the same frame.

Which engine drives the 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE?

The 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE is powered by a Perkins diesel engine. Engine and alternator are matched on the test bed, so the set reaches its rating without derating.

How loud is the 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE?

Sound pressure is 68-72 dB(A) @ 1 m on the soundproofed build. An open skid set is considerably louder and needs either an acoustic canopy or a separate plant room to meet site noise limits.

What enclosure options are available for the 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE?

The 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE is available as open skid, weatherproof silent canopy, containerised or mobile trailer. Enclosure choice changes footprint, weight, noise level and price, so specify it with the enquiry and the quotation will match the build.

What controller and alternator are fitted to the 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE?

The 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE ships with an automatic panel, manual/auto selector, LCD metering, RS485 Modbus and a brushless synchronous, 4-pole, single bearing, direct coupled alternator. Both are build options — alternative controllers and alternator makes can be specified when the order is placed.

How stable is the voltage output of the 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE?

On this set, voltage is held by an AVR, +/- 1% steady state, THD < 3% and the machine is built with Class H insulation, IP23 protection. That grade of regulation suits motors, pumps and most electronic loads; for sensitive IT or medical equipment, specify the higher-grade controller option.

What protection does the 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE have?

The controller trips on over-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence. These shutdowns stop the set before damage occurs, which is what makes an unattended standby installation safe to leave running.

What warranty comes with the 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE?

Warranty is 2 years or 2,000 hours, international coverage. It applies to the set as configured — running outside the rated duty, using non-specified fuel or skipping scheduled service will void it.

How do I get a firm price for the 15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE?

Send the model (15 KW 19 KVA Perkins Generator, EPA CARB Tier 4 Final, 3-PHASE), the duty (standby or prime), voltage and frequency, phase, and the enclosure type you need. Jinjia Power quotes against a confirmed configuration rather than a list price, so the figure you receive matches the machine that ships. Typical lead time is 20–30 days for units up to 1000 kW and 30–45 days above that.