Home > Diesel Generators > 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE
Perkins | - kW Diesel Generator | Model 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE | Jinjia Power

12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE

Perkins

Model: GPM-P12-60T4F

Power: 11.5KW 14.4KVA Standby / 10.3KW 12.9KVA Prime

Status: Brand New, 2 Years International Warranty

Volume, OEM and project pricing available on request.

📞 Get a Quote:86-13553838770
← ← Back to Products

Product Specifications

Model12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE
BrandPerkins
Standby Output- kW / - kVA (ESP)
Prime Output- kW / - kVA (PRP)
Power Factor0.80
Phase / ConnectionThree phase, 4-wire (star)
Voltage480 V
Frequency60 Hz
Rated Speed1800 rpm
Current @ Standby0.0 A per line
Current @ Prime0.0 A per line
EnginePerkins diesel, 1800 rpm
Fuel TypeDiesel, EN 590 / ASTM D975 grade
Fuel TankBase-frame tank, typically 50-100 L depending on build
AlternatorBrushless synchronous, 4-pole, single bearing, direct coupled
Insulation / EnclosureClass H insulation, IP23 protection
Voltage RegulationAVR, +/- 1% steady state, THD < 3%
ControllerAutomatic panel, manual/auto selector, LCD metering, RS485 Modbus
ProtectionOver-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence
Starting System12 V DC electric starter, 12 V charge alternator, battery included
CoolingRadiator cooled, 40 C ambient design
DimensionsOpen skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation.
Dry WeightOpen skid, silent canopy and containerised builds each have a different footprint and weight. The GA drawing with exact L×W×H and dry weight is issued with the quotation.
Noise LevelSoundproofed version typically 68-72 dB(A) @ 1 m
Enclosure OptionsOpen skid / weatherproof silent canopy / containerised / mobile trailer
EmissionEmission tier depends on the destination market and is confirmed per order — EU Stage V, US EPA Tier 4 Final, or unregulated where the market allows.
StandardISO 8528-1, performance class G1/G2; CE marking supported by the manufacturing plant's Declaration of Conformity
Warranty2 years or 2,000 hours, international coverage
AvailabilityIn stock, worldwide shipping
ConditionBrand New, 2 Years International Warranty
Quality100% Engineered and Assembled in China
ReliabilityLoad bank tested in China

Overview

12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE at a glance. This is a - kW / - kVA standby, - kW / - kVA prime diesel generating set built on a Perkins platform and wound for 480 V, 60 Hz three phase output at 1800 rpm. It sits in the small stationary class where the set is bought to carry a defined load block rather than to run a plant: a shop, a guesthouse, a telecom cabinet, a small cold store, a farm pump, or the essential circuit of a house. At this rating the physical size matters as much as the numbers, which is why the same machine is offered on an open skid and inside a canopy that fits through a standard doorway.

Reading the model code. 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE is a Jinjia-built set rather than a rebadged OEM unit, so the code carries the build information directly: the prefix identifies the engine family (P for Perkins, KB for Kubota, J for John Deere, K for Kohler), the number is the kW class, 60 means 60 Hz, T4F or T4i is the emission tier, and a trailing 1PHASE or 3PHASE fixes the winding. This page is the three phase build, - kW / - kVA standby.

Why the kVA is bigger than the kW. This is a three-phase set rated at 0.8 power factor, so - kW standby corresponds to - kVA and the two figures differ by exactly the reactive component the alternator has to carry. Quoting only the kW understates the copper and the switchgear: cables, breaker and busbar all size on the - kVA and the - A line current, while the engine only ever sees the - kW. That split is the most common source of undersized installations on three-phase sets in this class.

Standby and prime are two different machines in one frame. ISO 8528 defines standby (ESP) as the maximum a set may deliver for up to 200 hours a year on a varying load, with no overload capability, and prime (PRP) as the continuous rating under a varying load for unlimited hours with a 10 per cent overload window. This set is - kW / - kVA standby and - kW / - kVA prime, so the gap between the two, - kW, is the margin the engine keeps for overload and for altitude and temperature derating. If the load runs for days rather than hours, quote against prime and treat the standby figure as a peak that must not be sustained.

What the nameplate means once it is wired in. At - kVA this set pushes - A down each line on a 480 V three-phase supply, and - A at the prime rating. Those currents, not the kVA figure, are what the switchgear and the cable have to survive: the outgoing breaker should be a 16 A frame device set to trip above - A, and the run from the alternator terminals to the first panel should be 2.5 mm2 copper per phase for a normal 20 to 30 m span. On a single-phase set the same current sits on two conductors instead of three, so the cable is heavier for the same kVA, which is the hidden cost of going monophase above about 15 kVA.

The engine behind the badge. Perkins supplies the 400 and 1100 series into this class, and on the Tier 4 Final builds the after-treatment package is part of the engine, not an add-on. That is why a T4F set is taller and heavier than the same output in an export-tier build: the DOC and DPF sit in the exhaust path and need their own mounting and their own service interval. Perkins parts and service are handled through the Cat dealer network worldwide, which is the main reason buyers pay the premium.

Emissions. The set is offered in the emission configuration that suits the destination market. The export-tier build has no after-treatment and is the simplest to maintain; the Tier 4 Final build adds a DOC and DPF and is the only version that can be sold into the United States and Canada. Confirm the destination before fixing the engine variant, because the two builds are not interchangeable after the fact.

On the emission marking. This model code carries no trailing emission suffix, which means the set is built to whatever calibration the destination market requires rather than to a fixed stage. In practice that is an advantage at the quotation stage, because the same frame can be ordered as an export-tier build for markets with loose import rules or as a Tier 4 Final build where the rules are tight, without changing the electrical data, the alternator or the canopy. What it does mean is that the engine variant has to be fixed in writing before the order is placed. A set delivered as an export build cannot be upgraded to Tier 4 Final afterwards; the after-treatment is designed into the exhaust and the engine calibration is locked. Confirm the destination country and the certification the buyer needs, then pin the engine variant on the order.

The alternator end. The machine is a brushless, four-pole, single-bearing alternator direct-coupled to the engine flywheel housing, insulated to class H and protected to IP23. Regulation is by AVR at plus or minus one per cent steady state with total harmonic distortion under three per cent, which is clean enough for a UPS input but not clean enough to skip a filter in front of a sensitive analyser. Single bearing means the alternator has no bearing of its own on the drive end: it relies on the engine flywheel, which is why alignment and flywheel housing condition matter at every overhaul.

Control and protection. The standard panel gives manual and automatic modes, LCD metering of phase voltage, line current, kW, pf, kWh and engine oil pressure, coolant temperature and fuel level, plus a Modbus RTU port on RS485 for a building management system. Protection covers over-speed, low oil pressure, high coolant temperature, over and under voltage, over and under frequency, over-current and phase sequence, with the last twelve events held in a rolling log. That event log is the single most useful diagnostic on the machine: when a set trips at three in the morning, the log tells you which of the eight protections opened first.

Canopy and noise. The open skid build is the machine on a base frame with the radiator exposed, suitable for a plant room or a covered compound. The soundproofed canopy drops the one-metre level to roughly 68 to 72 dB(A) and is the version most export buyers take, because it also weatherproofs the set and lets it stand outdoors. Containerised and trailer-mounted builds use the same core machine with a different envelope, so the electrical data on this page holds across all four.

Where this rating actually fits. A - kW three-phase set is the entry point for light industrial and commercial standby: a workshop with a few machines, a cold store, a small hotel, a telecom site, a water treatment pump set. Three phase at this rating means motors start properly and the cable is a third of the copper of the single-phase equivalent. The constraint is balance: keep the phase-to-phase imbalance under 20 per cent, because an unbalanced load derates the alternator faster than an overload does.

Parallel operation and transfer. Below about 30 kVA, paralleling is rarely worth the control complexity: two sets need load-sharing governors, synchronising hardware and a common switchgear panel, and the cost of that exceeds the cost of simply buying one larger set. What this rating does need is a proper transfer arrangement: a manual changeover switch if the site is attended, an automatic transfer switch with a mains-failure sensor if it is not. The set itself accepts a remote start signal on a two-wire dry contact, which is all an ATS needs.

Maintenance that actually gets done. Oil and oil filter at 250 hours or annually, whichever comes first; fuel filter and air filter at 500 hours; coolant condition checked annually and changed at two years; valve clearance checked at 1,000 hours. The item most often skipped is the load bank test: a set that runs monthly on a light load will wet-stack and glaze the bores, and the first time it sees a real load it will smoke and under-perform. Run it at 75 per cent load for an hour every quarter, and record the exhaust temperature, because that is the number that tells you the engine is healthy.

Sizing it against a telecom site. A - kVA set at a base station is not sized on the average load, which is often under 3 kW, but on the air-conditioning surge and the battery recharge that follow a long outage. The rectifier bank pulls a steady 0.0 kW, the air conditioner adds a compressor start of three to five times its running current, and the batteries want everything the rectifier can give once mains returns. That combination is why a site that averages 4 kW is routinely given a - kVA machine: the set has to survive the worst ten seconds, not the average hour. Run the numbers with the compressor locked out during battery recharge and the rating often falls by a step, which is worth doing because the price step between frames is real. Fit a two-wire remote start from the site controller and let the set sit unloaded the rest of the year.

Acoustic treatment beyond the canopy. The soundproofed canopy gets the level down to roughly 68 to 72 dB(A) at one metre, which is fine outdoors and often not fine in a courtyard between buildings. Where the site is enclosed, the canopy is only the first step: orient the radiator discharge away from the nearest facade, put a solid barrier between the set and the boundary rather than an absorbent one, and avoid parallel hard surfaces that set up a standing wave. Do not add extra insulation inside the canopy without checking the cooling air path, because the most common way to overheat a soundproofed set is to make it quieter after it was designed.

AVR drift and voltage instability. When the voltage wanders or the lights flicker, the automatic voltage regulator is the first suspect, but it is usually the last cause. Check the connections and the sensing leads first, then the exciter diode pack, then the AVR itself. A failing diode produces a characteristic symptom: voltage that is fine on load and drops sharply when the load is removed. An AVR that has genuinely failed usually fails outright rather than drifting. Keep a spare AVR on site for a critical installation; it is a small part with a long lead time and it stops the whole machine.

Acceptance testing before it leaves. A set should be load bank tested before shipment, and the buyer should ask for the printout rather than a statement that it was done. The printout should show the set carrying its standby rating for at least an hour with stable voltage, stable frequency and coolant temperature inside limits, plus a step-load test to show recovery time. On a set with after-treatment, add a check that the exhaust back-pressure is within specification. A set that cannot produce that document is a set whose rating is a claim rather than a measurement.

Starting and cold start. The set starts on a 12 V electric starter drawing from a battery that is charged by a small engine-driven alternator. At temperatures above freezing that is unremarkable. Below about five degrees the compression-ignition engine needs help, and the help on this class of engine is a set of glow plugs or an air inlet heater, operated automatically by the controller with a short pre-heat before cranking. Two practical points follow. First, the battery is the weak link in cold weather, so a battery that is four years old will start the set in summer and fail in winter. Second, the pre-heat circuit draws current from the same battery, so a marginal battery plus a cold morning is a no-start. A mains float charger solves both.

How to order it. Quote five things together and the factory cannot get it wrong: the model (12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE), the standby and prime rating, the voltage and frequency (480 V, 60 Hz), the phase (three phase), and the enclosure (open skid, soundproofed canopy, containerised or trailer). Add the emission tier if the destination is regulated. Anything else, including the controller variant, the alternator brand and the fuel tank size, is a build option rather than a different machine.

Frequently Asked Questions

What are the standby and prime ratings of the 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE?

Standby output is - kW / - kVA (ESP), prime output is - kW / - kVA (PRP). The standby (ESP) figure is the maximum the set can carry for the duration of a mains failure and is not meant for continuous running. The prime (PRP) figure is what it can hold indefinitely at a varying load. Match the rating to the duty the set will actually see — running a standby-rated machine as prime voids the warranty.

What voltage and frequency does the 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE output?

The 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE is wound for 480 V, 60 Hz, three phase, 4-wire (star), running at 1800 rpm. Voltage and frequency are fixed when the set is built, so confirm the site supply before the order is released. Other voltages and both 50 Hz and 60 Hz builds are available on the same frame.

Which engine drives the 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE?

The 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE is powered by a Perkins diesel engine. Engine and alternator are matched on the test bed, so the set reaches its rating without derating.

How loud is the 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE?

Sound pressure is 68-72 dB(A) @ 1 m on the soundproofed build. An open skid set is considerably louder and needs either an acoustic canopy or a separate plant room to meet site noise limits.

What enclosure options are available for the 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE?

The 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE is available as open skid, weatherproof silent canopy, containerised or mobile trailer. Enclosure choice changes footprint, weight, noise level and price, so specify it with the enquiry and the quotation will match the build.

What controller and alternator are fitted to the 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE?

The 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE ships with an automatic panel, manual/auto selector, LCD metering, RS485 Modbus and a brushless synchronous, 4-pole, single bearing, direct coupled alternator. Both are build options — alternative controllers and alternator makes can be specified when the order is placed.

How stable is the voltage output of the 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE?

On this set, voltage is held by an AVR, +/- 1% steady state, THD < 3% and the machine is built with Class H insulation, IP23 protection. That grade of regulation suits motors, pumps and most electronic loads; for sensitive IT or medical equipment, specify the higher-grade controller option.

What protection does the 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE have?

The controller trips on over-speed, low oil pressure, high coolant temperature, over/under voltage, over/under frequency, over-current, phase sequence. These shutdowns stop the set before damage occurs, which is what makes an unattended standby installation safe to leave running.

What warranty comes with the 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE?

Warranty is 2 years or 2,000 hours, international coverage. It applies to the set as configured — running outside the rated duty, using non-specified fuel or skipping scheduled service will void it.

How do I get a firm price for the 12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE?

Send the model (12 KW Generator 14 kVA, Perkins, EPA Tier 4 Final, 3-PHASE), the duty (standby or prime), voltage and frequency, phase, and the enclosure type you need. Jinjia Power quotes against a confirmed configuration rather than a list price, so the figure you receive matches the machine that ships. Typical lead time is 20–30 days for units up to 1000 kW and 30–45 days above that.