| SKU | DECS100-A01 |
| Brand | BASLER |
| Model Number | DECS100-A01 |
| Regulator Type | Digital Automatic Voltage Regulator |
| Excitation System | Self-excited, shunt or auxiliary-winding fed |
| Sensing Input | Single-phase sensing with jumper-selectable voltage range |
| Power Input | Single-phase, 50 / 60 Hz |
| Output Voltage | 63 Vdc class |
| Continuous Field Current | 4 Adc continuous class |
| Forcing Current | Short-term forcing current available for load steps |
| Field Resistance (Min) | 15 ohm minimum |
| Regulation Accuracy | +/-1.0 per cent |
| Response Time | Digital, fixed stability curve |
| Frequency Range | 50 / 60 Hz, jumper selected |
| Under-Frequency Protection | Volts-per-hertz roll-off |
| Voltage Adjustment | Internal trim potentiometer |
| Paralleling / Droop | Reactive droop via optional CT |
| Build-Up Voltage | Builds up from residual voltage |
| Thermal Drift | Low thermal drift |
| Operating Temperature | -40 to +60 degC |
| Storage Temperature | -40 to +85 degC |
| Protection Features | Over-excitation shutdown, loss of sensing |
| Compatible Alternators | Small and mid-size alternators, 20-500 kVA |
| Mounting | Panel or Surface Mount |
| Weight | Approximately 2.5 lbs (1.13 kg) |
| Lifecycle Status | In production |
| Availability | IN STOCK, Same day shipping Worldwide available |
| Condition | Brand New, 1 Year International Warranty |
| Warranty | 1 Year International Warranty |
Short version. The DECS100-A01 is a Digital Automatic Voltage Regulator. It supplies the exciter field, senses the alternator output and corrects the difference several times a second. Its rating is 4 Adc continuous class, its field resistance window 15 ohm, its accuracy +/-1.0 per cent, and it is intended for machines whose field winding sits inside that window. Read the rest of this page as the detail behind those three figures.
Excitation architecture. Self-excited, shunt or auxiliary-winding fed. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. If the machine will not hold voltage at all, disconnect the field and measure the sensing voltage first. That one reading separates a sensing fault from a field fault.
Sensing. Single-phase sensing with jumper-selectable voltage range. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Where a spare is being held, hold the drawing with it. A board without its wiring diagram costs a shift of production time to install.
Power stage and field drive. Power input Single-phase, 50 / 60 Hz, output 63 Vdc class. Field current rating 4 Adc continuous class, forcing capability Short-term forcing current available for load steps, field resistance window 15 ohm. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Static accuracy is measured on a resistive load at constant frequency. Real loads and real governors are neither, so treat the figure as a comparison between boards rather than a promise.
Accuracy and response. +/-1.0 per cent steady-state accuracy, Digital, fixed stability curve, thermal drift Low thermal drift. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. A regulator rated for a minimum field resistance of a few ohms will not drive a high resistance field to full current, however good its specification looks on paper.
Frequency behaviour. Rated for 50 / 60 Hz, jumper selected, with Volts-per-hertz roll-off. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. A regulator rated for a minimum field resistance of a few ohms will not drive a high resistance field to full current, however good its specification looks on paper.
Paralleling. Reactive droop via optional CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. Terminal boxes are hot, dirty and vibrating. Anything mounted inside one should be judged on how it behaves in year eight, not on how it reads on the bench.
Protection built into the regulator. Over-excitation shutdown, loss of sensing. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. Where a spare is being held, hold the drawing with it. A board without its wiring diagram costs a shift of production time to install.
What it fits. Small and mid-size alternators, 20-500 kVA. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. If the machine will not hold voltage at all, disconnect the field and measure the sensing voltage first. That one reading separates a sensing fault from a field fault.
Field notes on this model. The DECS-100 is the entry point of the Basler digital line: a sealed, potted digital regulator for small and mid-size alternators where an analogue AVC63 would historically have been used. The A01 / A05 / A11 / A15 and B01 / B05 / B11 / B15 suffixes denote the sensing and output configuration, so the suffix has to match the alternator before the unit is ordered.
Reading the application backwards. Most regulator problems arrive described as engine trouble. A set that hunts on load, or whose voltage sags for two seconds after a contactor closes, is usually reporting a field current limit rather than a fuel problem. On a DECS100-A01 the first thing to check is whether the 4 Adc continuous class figure is being reached on a cold morning, because field resistance rises with temperature in the opposite direction to copper and a board that is marginal at 20 degC can be comfortable at 50 degC or the other way round depending on the winding.
Power and sensing are not the same circuit. The power input on a DECS100-A01 can come from a different winding from the sensing input, and on PMG machines it always does. Wire them as two separate circuits, fused separately, and label both. The single most expensive mistake on a PMG set is landing the sensing leads on the PMG supply, which gives the regulator a voltage reference that rises with speed and produces a set whose voltage tracks engine rpm.
Bench test before installation. Where a spare board is available, test it on the bench with a variable AC supply into the power input and a resistor bank as the field load. A board that cannot hold a steady output into a resistor will not hold it into an exciter either, and finding that out on the bench costs nothing.
Temperature drift of the field. Copper rises about 0.4 per cent in resistance per degC, so a field that measures 12 ohm cold will measure around 15 ohm at a 70 degC winding temperature. A regulator set up on a cold machine and never re-checked will therefore be running at a different operating point every time the season changes, and the symptom is a voltage that is correct in winter and low in summer.
Spares strategy. Keep one regulator of each family in stock rather than several of one. A failed AVR takes a set off line in seconds and the replacement lead time is measured in days, which is why the cost of the spare is trivial compared with the cost of the outage.
Documentation. Insist on the wiring drawing for the exact suffix being supplied. Generic family drawings are the reason installations end up with the sensing on the wrong tap, and the resulting fault is indistinguishable from a faulty board.
Parallel operation is a different animal. A single set on an island load only has to hold voltage. Two sets in parallel also have to agree about reactive load, and that agreement is made or broken by the droop circuit, not by the voltage accuracy. If a site is going to parallel, the regulator choice has to be made with the droop method in mind from the beginning, because retrofitting load sharing onto a board that was never specified for it costs more than buying the right one.
Earthing and shielding. The regulator reference is the machine frame. Bond the AVR mounting plate to the frame with a dedicated conductor rather than relying on the mounting screws, and earth the sensing cable shield at one end only. When a set shows a voltage that wanders slowly with no load change, the cause is usually a circulating current in the shield rather than a failing board.