Status: IN STOCK, Same day shipping Worldwide available | Brand New, 1 Year International Warranty
* Contact us for pricing and full specifications
| SKU | AVC63-4D |
| Brand | BASLER |
| Model Number | AVC63-4D |
| Regulator Type | Analogue Automatic Voltage Regulator |
| Excitation System | Self-excited, shunt or auxiliary-winding fed |
| Sensing Input | 190-264 Vac single-phase, 120 V and 240 V jumper selectable, 50 / 60 Hz |
| Power Input | 90-240 Vac single-phase |
| Output Voltage | 63 Vdc maximum at 240 Vac input, 32 Vdc at 120 Vac input |
| Continuous Field Current | 4 Adc continuous |
| Forcing Current | 8 Adc for 10 s |
| Field Resistance (Min) | 15 ohm minimum (10 ohm below 175 Vac input), 100 ohm maximum |
| Regulation Accuracy | +/-1.0 per cent over a 4 per cent engine speed change |
| Response Time | About 20 ms |
| Frequency Range | 50 / 60 Hz, jumper selected |
| Under-Frequency Protection | Roll-off knee 45-51 Hz on 50 Hz or 54-61 Hz on 60 Hz, with a U/F indicator |
| Voltage Adjustment | +/-10 to +/-15 per cent with a 1-2 kohm, 1 W potentiometer |
| Paralleling / Droop | Reactive droop via CT |
| Build-Up Voltage | Builds up from 5 Vac residual |
| Thermal Drift | 0.05 per cent per degC |
| Operating Temperature | -40 to +60 degC |
| Storage Temperature | -65 to +85 degC |
| Protection Features | Over-excitation shutdown, loss of sensing protection, integral high-breaking-capacity fuse |
| Compatible Alternators | Stamford, Leroy Somer, Marathon, Marelli and Mecc Alte alternators up to about 500 kVA |
| Mounting | Panel or terminal-box mount |
| Dimensions (L x W x H) | 6.75" x 4.5" x 2.25" (171 x 114 x 57 mm) |
| Weight | Approximately 1.5 lbs (0.68 kg) |
| Lifecycle Status | In production |
| Availability | IN STOCK, Same day shipping Worldwide available |
| Condition | Brand New, 1 Year International Warranty |
| Warranty | 1 Year International Warranty |
Position in the range. The AVC63-4D sits in the BASLER regulator family carrying the designation Analogue Automatic Voltage Regulator. Its place is defined by the field current it can hold, 4 Adc continuous, against the field resistance it can drive, 15 ohm (10 ohm below 175 Vac, at +/-1.0 per cent accuracy over -40 to +60 degC. Where a machine falls outside either of the first two figures, a different member of the same family is the correct answer rather than a workaround.
Excitation architecture. Self-excited, shunt or auxiliary-winding fed. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. Take a photograph of the terminal block before removing anything. Wiring drawings for older machines are frequently wrong, and the photograph is the only reliable record.
Sensing. 190-264 Vac single-phase, 120 V and 240 V jumper selectable, 50 / 60 Hz. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Any AVR that has been in service for more than ten years is running on borrowed time, and the failure always happens at the least convenient moment.
Power stage and field drive. Power input 90-240 Vac single-phase, output 63 Vdc maximum at 240 Vac input, 32 Vdc at 120 Vac input. Field current rating 4 Adc continuous, forcing capability 8 Adc for 10 s, field resistance window 15 ohm (10 ohm below 175 Vac. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Static accuracy is measured on a resistive load at constant frequency. Real loads and real governors are neither, so treat the figure as a comparison between boards rather than a promise.
Accuracy and response. +/-1.0 per cent steady-state accuracy, About 20 ms, thermal drift 0.05 per cent per degC. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. A voltage that is correct at no load and low at full load is almost never an accuracy problem. It is a current limit, a resistance problem or a cable problem.
Frequency behaviour. Rated for 50 / 60 Hz, jumper selected, with Roll-off knee 45-51 Hz on 50 Hz or 54-61 Hz on 60 Hz, with a U/F indicator. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. Terminal boxes are hot, dirty and vibrating. Anything mounted inside one should be judged on how it behaves in year eight, not on how it reads on the bench.
Paralleling. Reactive droop via CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.
Protection built into the regulator. Over-excitation shutdown, loss of sensing protection, integral high-breaking-capacity fuse. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. If two identical sets behave differently on the same load, swap the regulators before swapping anything else. The result tells you which side of the machine the fault is on.
What it fits. Stamford, Leroy Somer, Marathon, Marelli and Mecc Alte alternators up to about 500 kVA. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. Static accuracy is measured on a resistive load at constant frequency. Real loads and real governors are neither, so treat the figure as a comparison between boards rather than a promise.
Field notes on this model. Basler describes the AVC63 as the universal regulator that reduces inventory to one device on the shelf, and that is exactly how it is used in the field: one potted analogue AVR that fits most small and mid-size alternators. The sealed housing is what makes it survive engine-room vibration and conductive dust, and there are only three adjustments, so there is very little to mis-configure on site.
Where this regulator does not belong. A AVC63-4D is a voltage regulator, not a protection relay and not a governor interface. If the site needs loss-of-mains detection, reverse power protection or synchronising, those functions live in the controller, not here. Expecting the AVR to carry them is how installations end up with a set that holds voltage beautifully and still trips the site on a mains failure.
Documentation that survives the job. Photograph the terminal block before disconnecting anything, and write the sensing tap and the field resistance on the inside of the terminal box lid. Ten years later that note is the only thing that will let the next engineer choose a replacement without a full survey.
What to record. Write down the sensing tap used, the field resistance cold, the field current at no load and at full load, and the voltage trim position. Those four numbers turn the next service visit from an investigation into a comparison.
Why resistance matters more than current rating. A regulator delivers a voltage, and the field decides how much current that voltage produces. A board rated at 4 Adc continuous into a low resistance field will deliver far less into a high resistance one, because the output voltage is the limit. This is why an AVR that is electrically perfect on paper can fail to excite a particular alternator, and why the resistance figure belongs in the quotation rather than in the manual.
Voltage low under load only. This is the classic field current limit symptom. Measure the field current at full load and compare it with the 4 Adc continuous figure for the AVC63-4D. If the board is at its limit, either the board is too small for the alternator or the field resistance has risen. A rewind, a corroded terminal or a long cable run will all produce the same reading.
Lifecycle status. If the board being replaced is discontinued, price the current replacement at the same time as the old-stock option. On a machine that is going to run for another ten years the current production board is almost always the cheaper decision even when the old stock is available.
The retrofit case. Most AVC63-4D sales are retrofits, not new build. The machine is ten to twenty years old, the original board has failed, and the drawing is gone. In that situation the useful evidence is the exciter field resistance measured with a meter, the residual voltage measured at the AVR terminals with the machine turning at rated speed and no load, and the nameplate kVA. Those three readings will identify a compatible board even when the original part number cannot be found anywhere.
Fusing. Fit the fuse the manual specifies and nothing larger. A bigger fuse does not protect the regulator better, it protects it later. On a AVC63-4D the fuse is there to clear a field short before the thyristor is destroyed, and a 20 A fuse in place of an 8 A one turns a cheap board replacement into a rewind.