| SKU | AVC125-10A1 |
| Brand | BASLER |
| Model Number | AVC125-10A1 |
| Regulator Type | Analogue Automatic Voltage Regulator |
| Excitation System | Self-excited or PMG |
| Sensing Input | Single-phase or three-phase, 380-480 V class |
| Power Input | Single-phase, 50 / 60 Hz |
| Output Voltage | 125 Vdc class |
| Continuous Field Current | 10 Adc continuous |
| Forcing Current | 15 Adc for 10 s |
| Field Resistance (Min) | 18 ohm minimum |
| Regulation Accuracy | +/-1.0 per cent |
| Response Time | About 20 ms |
| Frequency Range | 50 / 60 Hz |
| Under-Frequency Protection | Volts-per-hertz roll-off |
| Voltage Adjustment | Internal trim potentiometer |
| Paralleling / Droop | Reactive droop via CT |
| Build-Up Voltage | Builds up from residual voltage |
| Thermal Drift | 0.05 per cent per degC |
| Operating Temperature | -40 to +60 degC |
| Storage Temperature | -40 to +85 degC |
| Protection Features | Over-excitation shutdown, integral fuse |
| Compatible Alternators | Large frame alternators, 1000-2500 kVA |
| Mounting | Panel or surface mount |
| Lifecycle Status | In production |
| Availability | IN STOCK, Same day shipping Worldwide available |
| Condition | Brand New, 1 Year International Warranty |
| Warranty | 1 Year International Warranty |
Position in the range. The AVC125-10A1 sits in the BASLER regulator family carrying the designation Analogue Automatic Voltage Regulator. Its place is defined by the field current it can hold, 10 Adc continuous, against the field resistance it can drive, 18 ohm, at +/-1.0 per cent accuracy over -40 to +60 degC. Where a machine falls outside either of the first two figures, a different member of the same family is the correct answer rather than a workaround.
Excitation architecture. Self-excited or PMG. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. A regulator rated for a minimum field resistance of a few ohms will not drive a high resistance field to full current, however good its specification looks on paper.
Sensing. Single-phase or three-phase, 380-480 V class. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. Any AVR that has been in service for more than ten years is running on borrowed time, and the failure always happens at the least convenient moment.
Power stage and field drive. Power input Single-phase, 50 / 60 Hz, output 125 Vdc class. Field current rating 10 Adc continuous, forcing capability 15 Adc for 10 s, field resistance window 18 ohm. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. Load sharing between parallel sets is set up with an instrument, not by ear. A droop adjustment made by listening to the sets will be wrong at every load other than the one it was set at.
Accuracy and response. +/-1.0 per cent steady-state accuracy, About 20 ms, thermal drift 0.05 per cent per degC. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.
Frequency behaviour. Rated for 50 / 60 Hz, with Volts-per-hertz roll-off. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. Any AVR that has been in service for more than ten years is running on borrowed time, and the failure always happens at the least convenient moment.
Paralleling. Reactive droop via CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. Load sharing between parallel sets is set up with an instrument, not by ear. A droop adjustment made by listening to the sets will be wrong at every load other than the one it was set at.
Protection built into the regulator. Over-excitation shutdown, integral fuse. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. Where a spare is being held, hold the drawing with it. A board without its wiring diagram costs a shift of production time to install.
What it fits. Large frame alternators, 1000-2500 kVA. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. The most common cause of intermittent excitation loss is a crimp terminal that was never properly made. Wiggle the harness with the machine running before replacing anything.
Field notes on this model. The AVC125-10 is the 125 Vdc member of the Basler analogue line, used where the exciter field is wound for a higher voltage and a lower current than a 63 Vdc machine. It is common on large frame alternators and on machines originally supplied with a Basler SR8A or SR9A.
Where this board earns its place. The AVC125-10A1 is normally the answer when a BASLER machine has lost regulation and the original board is either unavailable or priced like a small car. What decides the fit is not the brand name on the cover but three numbers: the field resistance window, the continuous field current, and the sensing voltage the machine actually delivers at the AVR terminals. Get those three right and the regulator behaves; get any one of them wrong and the symptom usually looks like a mechanical fault rather than an electrical one.
Fusing. Fit the fuse the manual specifies and nothing larger. A bigger fuse does not protect the regulator better, it protects it later. On a AVC125-10A1 the fuse is there to clear a field short before the thyristor is destroyed, and a 20 A fuse in place of an 8 A one turns a cheap board replacement into a rewind.
Commissioning sequence. Start with the machine at rated speed, no load, and the field disconnected. Confirm the sensing voltage at the AVR terminals is inside the window the board expects, then connect the field with the voltage trim at minimum. Bring the trim up slowly and watch the field current, not the terminal voltage, because the terminal voltage will look correct long before the field current has stabilised on a cold winding.
Temperature drift of the field. Copper rises about 0.4 per cent in resistance per degC, so a field that measures 12 ohm cold will measure around 15 ohm at a 70 degC winding temperature. A regulator set up on a cold machine and never re-checked will therefore be running at a different operating point every time the season changes, and the symptom is a voltage that is correct in winter and low in summer.
Spares strategy. Keep one regulator of each family in stock rather than several of one. A failed AVR takes a set off line in seconds and the replacement lead time is measured in days, which is why the cost of the spare is trivial compared with the cost of the outage.
Before the order is placed. Confirm the alternator frame, the measured field resistance, the sensing voltage at rated speed, the excitation system (shunt, AREP, auxiliary winding or PMG) and the mounting footprint. Five answers, no guessing. Every wrong regulator order we see traces back to one of those five being assumed rather than measured.
Reading the application backwards. Most regulator problems arrive described as engine trouble. A set that hunts on load, or whose voltage sags for two seconds after a contactor closes, is usually reporting a field current limit rather than a fuel problem. On a AVC125-10A1 the first thing to check is whether the 10 Adc continuous figure is being reached on a cold morning, because field resistance rises with temperature in the opposite direction to copper and a board that is marginal at 20 degC can be comfortable at 50 degC or the other way round depending on the winding.
Fusing. Fit the fuse the manual specifies and nothing larger. A bigger fuse does not protect the regulator better, it protects it later. On a AVC125-10A1 the fuse is there to clear a field short before the thyristor is destroyed, and a 20 A fuse in place of an 8 A one turns a cheap board replacement into a rewind.