86-0769-89610677 / 86-13553838770 | info@jinjiadongli.com
Home > VOLTAGE REGULATORS > AVC125-10A2 Basler AVR โ€“ Automatic Voltage Regulator
BASLER AVC125-10A2 Analogue AVR | Voltage Regulator | Jinjia Power

BASLER AVC125-10A2 Analogue AVR - Analogue Automatic Voltage Regulator for BASLER Alternators | OEM Replacement

AVC125-10A2

Status: IN STOCK, Same day shipping Worldwide available | Brand New, 1 Year International Warranty

* Contact us for pricing and full specifications

๐Ÿ“ž Get a Quote๏ผš86-13553838770
โ† Back to products

Specifications

SKUAVC125-10A2
BrandBASLER
Model NumberAVC125-10A2
Regulator TypeAnalogue Automatic Voltage Regulator
Excitation SystemSelf-excited or PMG
Sensing InputSingle-phase or three-phase, 380-480 V class
Power InputSingle-phase, 50 / 60 Hz
Output Voltage125 Vdc class
Continuous Field Current10 Adc continuous
Forcing Current15 Adc for 10 s
Field Resistance (Min)18 ohm minimum
Regulation Accuracy+/-1.0 per cent
Response TimeAbout 20 ms
Frequency Range50 / 60 Hz
Under-Frequency ProtectionVolts-per-hertz roll-off
Voltage AdjustmentInternal trim potentiometer
Paralleling / DroopReactive droop via CT
Build-Up VoltageBuilds up from residual voltage
Thermal Drift0.05 per cent per degC
Operating Temperature-40 to +60 degC
Storage Temperature-40 to +85 degC
Protection FeaturesOver-excitation shutdown, integral fuse
Compatible AlternatorsLarge frame alternators, 1000-2500 kVA
MountingPanel mount or chassis mount
Lifecycle StatusIn production
AvailabilityIN STOCK, Same day shipping Worldwide available
ConditionBrand New, 1 Year International Warranty
Warranty1 Year International Warranty

Product Overview

BASLER AVC125-10A2. This is a Analogue Automatic Voltage Regulator from the BASLER range, supplied as a direct replacement for the same model number in the field. The figures that matter are printed in the table above and repeated here so the page can be read on its own: field current rating 10 Adc continuous, field resistance window 18 ohm, accuracy +/-1.0 per cent, working range -40 to +60 degC. Everything else on this page exists to explain how those four numbers decide whether the unit fits a particular alternator.

Excitation architecture. Self-excited or PMG. That single sentence decides most of the regulator's behaviour in a fault: whether the field survives a close-up short circuit, whether the machine builds up from residual voltage on its own, and how much the terminal voltage dips when a large motor starts on the same bus. Any AVR that has been in service for more than ten years is running on borrowed time, and the failure always happens at the least convenient moment.

Sensing. Single-phase or three-phase, 380-480 V class. The sensing circuit is the regulator's only view of the outside world, so its wiring matters as much as its specification. A voltage error introduced by a loose terminal or a long run of untwisted cable is indistinguishable, from the regulator's point of view, from a genuine voltage error on the alternator. A regulator is a closed loop with a slow plant attached, and the plant is a large inductance. That is why the stability adjustment exists and why it is set after, not before, the voltage is correct.

Power stage and field drive. Power input Single-phase, 50 / 60 Hz, output 125 Vdc class. Field current rating 10 Adc continuous, forcing capability 15 Adc for 10 s, field resistance window 18 ohm. These are not independent numbers: the output voltage ceiling and the field resistance together set the maximum current the board can actually deliver, and the continuous rating is only reachable at the low end of the resistance window. A set that runs at reduced speed will show low voltage on any regulator. Check engine speed against the nameplate before touching the excitation system.

Accuracy and response. +/-1.0 per cent steady-state accuracy, About 20 ms, thermal drift 0.05 per cent per degC. In practice the accuracy figure is the least interesting of the three. What an operator notices is recovery after a load step, which is governed by response and by available forcing current, and what a maintenance engineer notices after two years is drift, which is governed by the reference circuit and the ambient temperature inside the terminal box. Terminal boxes are hot, dirty and vibrating. Anything mounted inside one should be judged on how it behaves in year eight, not on how it reads on the bench.

Frequency behaviour. Rated for 50 / 60 Hz, with Volts-per-hertz roll-off. The frequency-sensitive function exists to protect the prime mover, not the alternator: as engine speed falls the regulator reduces excitation so the alternator stops demanding torque the engine cannot supply. Without it, an overloaded engine is dragged down until it stalls, and the alternator is blamed for a fault that belongs to the fuel or governor system. A regulator rated for a minimum field resistance of a few ohms will not drive a high resistance field to full current, however good its specification looks on paper.

Paralleling. Reactive droop via CT. On a single set this circuit does nothing. On two or more sets it is the only thing that stops the machines from exchanging reactive power in a slow oscillation, and it is the first place to look when a parallel installation shows a circulating current that nobody can explain. Where a board has been superseded, the replacement usually fits the same footprint but not the same terminal numbering. Read the drawing, do not read the old wiring.

Protection built into the regulator. Over-excitation shutdown, integral fuse. These functions protect the alternator and the regulator, not the installation. Downstream protection, loss of mains and reverse power all belong to the controller, and a site that relies on the AVR for them is a site that will eventually trip in a way nobody can explain. If two identical sets behave differently on the same load, swap the regulators before swapping anything else. The result tells you which side of the machine the fault is on.

What it fits. Large frame alternators, 1000-2500 kVA. Lifecycle status: In production. Both halves of that sentence matter at order time. A board that fits perfectly but has been discontinued is a different commercial decision from one that fits and is in current production, and the price difference rarely reflects the difference in risk. Field resistance is a temperature-dependent number. A reading taken on a cold morning and a reading taken after an hour at load are both correct and both different.

Field notes on this model. The AVC125-10 is the 125 Vdc member of the Basler analogue line, used where the exciter field is wound for a higher voltage and a lower current than a 63 Vdc machine. It is common on large frame alternators and on machines originally supplied with a Basler SR8A or SR9A.

Where this board earns its place. The AVC125-10A2 is normally the answer when a BASLER machine has lost regulation and the original board is either unavailable or priced like a small car. What decides the fit is not the brand name on the cover but three numbers: the field resistance window, the continuous field current, and the sensing voltage the machine actually delivers at the AVR terminals. Get those three right and the regulator behaves; get any one of them wrong and the symptom usually looks like a mechanical fault rather than an electrical one.

Documentation that survives the job. Photograph the terminal block before disconnecting anything, and write the sensing tap and the field resistance on the inside of the terminal box lid. Ten years later that note is the only thing that will let the next engineer choose a replacement without a full survey.

Under-frequency check. Run the set at reduced speed and confirm the volts-per-hertz knee actually operates. This test is skipped on most commissioning sheets and it is the one that saves an engine on a real overload, because the knee is what stops the alternator from loading a lugging engine into a stall.

Series resistance is not a fix. Adding a resistor in series with the field to bring it inside a regulator window costs forcing current exactly when the machine needs it most. If the field resistance is outside the window, change the board, not the circuit.

Symptom first, board second. A set that will not build up voltage has one of four causes: no residual magnetism, a broken sensing circuit, a failed regulator, or a field circuit open. Test them in that order, because the first two are free to check and the third is not. Flashing the field with a battery through a resistor will separate a residual problem from a regulator problem in under a minute.

Warranty and what it covers. A one year warranty on a regulator is meaningful only if it covers a field-side failure and not just a dead-on-arrival check. Ask whether a board that fails after six months in service is replaced without argument, because that is the failure mode that actually happens.

Standby versus prime power. A standby set runs a few hundred hours a year and its regulator spends most of its life cold; a prime power set runs continuously and its regulator spends its life at operating temperature. The AVC125-10A2 is rated for -40 to +60 degC, which is fine in both cases provided the terminal box has any ventilation at all. What changes between the two duties is the capacitor ageing inside the board, not the semiconductor, so a prime power machine should have the regulator inspected on a schedule rather than on failure.

Documentation that survives the job. Photograph the terminal block before disconnecting anything, and write the sensing tap and the field resistance on the inside of the terminal box lid. Ten years later that note is the only thing that will let the next engineer choose a replacement without a full survey.

Jinjia Power Equipment Co., Ltd | Address: No.737, Guanzhang Road, Liaobu Town, Dongguan, China

Phone: 86-13553838770 | 86-0769-89610677 | info@jinjiadongli.com

Jinjia Power, Quality Assured